Permitting Authorities / Oklahoma / City of Jenks - Building Inspections Department

Do you need a permit to replace a roof in Jenks, OK?

Adopted code

City of Jenks - Building Inspections Department

The permitting authority for the City of Jenks, Oklahoma. The Building Inspections Department issues residential and commercial building permits covering new construction and remodeling, and performs staged inspections, including a framing inspection that verifies the roof has been completed before insulation and sheetrock proceed.

Roof code checklist: Jenks, OK

ItemAnswerCode citeSourceVerified
Permit to replace a roofNot published
Repair permit thresholdNot published
Layer limit / roof-overPublishedR908.3.1.12022 09 14 IRC 2018 Permanent Rul...2026-07-19
Deck & sheathingPublishedR905.2.12022 09 14 IRC 2018 Permanent Rul...2026-07-19
Drip edgeYesR905.2.8.52022 09 14 IRC 2018 Permanent Rul...2026-07-20
Ice & water shieldYes2022 09 14 IRC 2018 Permanent Rul...2026-07-20
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNolibrary.municode.com2026-07-31
Wind design criteriaNot published
Adopted codePublishedlibrary.municode.com2026-07-31
Contractor license / registrationNot published
Sales & use taxPublishedcopo3Q26.pdf2026-07-18

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
City of Jenks, Oklahoma
Jurisdiction type
city
Address
211 North Elm Street, Jenks, OK 74037
Contact
  • url: https://www.jenks.com/230/Building-Inspections
  • phone: 918-556-7439
Permit process note
The Master Fee Schedule prices "Residential Building Permit Fees" under the scope "New Construction and Remodel" by estimated construction valuation (e.g., $100.00 for $1,000-$40,000; 0.25% of cost from $10,000.01-$100,000.00), with no separate roofing or re-roofing permit line item listed.
Inspection requirements
The Building Permit Procedures document lists required inspection stages including Footing, Plumbing Rough, Mechanical Rough, Slab, a combined Electrical Rough/Plumbing Top Out/Mechanical Top Out inspection, Framing, and Final. It states the Framing inspection is "to be made after all of the following have been completed: roof, framing, fire blocking, bottom plates, anchor bolts or equivalent foundation anchorage, and energy seal." Inspections are scheduled by calling City Hall, and final inspections will not be performed until water and sewer taps and all other fees have been paid.
Adopted code
Jenks Code of Ordinances Sec. 4-1-1(A) ("Adoption of Codes"), as last amended by Ord. No. 1613, § I (4-18-2023), adopts the "2018 International Residential Code for One and Two Family Dwellings and Townhouses," together with the 2018 editions of the International Building, Existing Building, Fire, Plumbing, Mechanical and Fuel Gas Codes and the 2017 National Electrical Code, "all as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC)." Note that the city's Adopted Building Codes webpage has not been updated to match and still lists the 2015 International Residential Code with an effective date of April 5, 2022; the codified section was amended a year later and is the controlling instrument.
Drip edge
Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Jenks Code of Ordinances Sec. 4-1-1 "Adoption of Codes" adopts the 2018 IRC "as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC) as if fully set out at length herein" -- confirmed (this record's existing roof_layer_limit and deck_sheathing_requirements fields) by a full read of Sec. 4-1-1 through 4-1-8, none of which addresses any Chapter 9 Roof Assemblies provision. Oklahoma's operative text is therefore the OUBCC 2018 IRC Permanent Rule, whose amended R905.2.8.5 requires a drip edge at eaves and rake edges (with a shingle-mold exception). About drip edge
Ice & water shield
Required — A 36-inch-wide ice barrier IS required in all valleys ("installed in all valleys, run the length of the valley, and centered on the valley") and at all changes in roof pitch where the lower roof has a lower pitch than the upper roof -- unconditional requirements added to IRC Sec. 905.1.2 by the OUBCC 2018 IRC Permanent Rule, "the statewide minimum code for residential building construction... pursuant to 59 O.S. Sec. 1000.23." Jenks Sec. 4-1-1 through 4-1-8 contains no local amendment touching Sec. 905.1.2 or any other roofing provision, and no local climate-design table addressing the eave ice-damming trigger was found, so only the unconditional valley and pitch-change requirement is stated here. About ice & water barrier
Impact-resistant roofing
Not required — Jenks Code of Ordinances, Chapter 4 (Building, Plumbing, Electrical, and Mechanical Installations), Article 1 (Building Code and Regulations), Sec. 4-1-1(A) "Adoption of Codes" (Ord. No. 1253, 6-15-2009; Ord. No. 1305, 9-6-2011; Ord. No. 1334, 9-3-2013; Ord. No. 1579, § I, 4-5-2022; Ord. No. 1613, § I, 4-18-2023) adopts "the 2018 International Residential Code for One and Two Family Dwellings and Townhouses ... as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC) as if fully set out at length herein." Sec. 4-1-1 through Sec. 4-1-8 (the whole of Article 1) were read in full and contain no locally restated amendment to IRC Chapter 9 Roof Assemblies and no UL 2218, Class 4, or impact-resistance provision; the 2018 IRC is adopted by blanket reference to the OUBCC text rather than by section-by-section local restatement. The matching-vintage statewide OUBCC IRC 2018 Permanent Rule (OAC 748:20-6-14, "IRC 2018 Chapter 9 Roof Assemblies," 13 modifications), which this blanket adoption incorporates, likewise contains no UL 2218, Class 4, or hail-impact provision.
Roof layer limit / recover
Jenks Code of Ordinances Sec. 4-1-1(A) "Adoption of Codes" adopts the 2018 IRC "as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC) as if fully set out at length herein," with no Jenks-specific amendment to IRC Chapter 9 anywhere in Article 1 (Building Code and Regulations) -- confirmed by reading Sec. 4-1-1 through 4-1-8 in full; none addresses roofing/recover. The governing text is therefore the OUBCC's own statewide R908.3.1.1: "A roof re-cover shall not be permitted where any of the following conditions occur: 1. Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. 2. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. 3. Where the existing roof has two or more applications of any type of roof covering. 4. Where the existing roof has one or more application of asphalt shingles additional applications of asphalt shingles shall not be permitted." (OAC 748:20-6-14(13)).
Deck & sheathing requirements
Same blanket-adoption finding as roof_layer_limit above -- Jenks Sec. 4-1-1 through 4-1-8 contains no local amendment to IRC R905 -- so the governing text is the OUBCC's own statewide R905.2.1: "Asphalt shingles shall be fastened to solidly sheathed decks. Solidly sheathed decks shall be defined as sawn lumber boards or structural panels that provide a solid holding power for fasteners that do not have deficit conditions (gaps greater than those allowed by the roof covering manufacturer's installation instructions, warped, split, cracked, deteriorated or rotten boards)." (OAC 748:20-6-14(2)).
Sales & use tax
Combined rate 8.417% inside Jenks city limits (state 4.5% + City of Jenks 3.55% + Tulsa County 0.367%). The OTC rate chart lists only one jurisdiction code for Jenks (COPO 7208, Tulsa County), so the combined rate does not vary by address within the city. Oklahoma taxes roofing contractors as consumers/users: they pay sales tax on materials, supplies, and equipment at the point of purchase from the vendor, and do not separately charge the homeowner sales tax on labor or the finished job (Oklahoma Tax Commission Rule OAC 710:65-7-13(a): "Contractors are defined by statute as consumer/users and must pay sales tax on all taxable services and tangible personal property, including materials, supplies, and equipment purchased to develop, repair, alter, remodel, and improve real property."). No construction use tax collected at building-permit issuance was found in OTC or city sources -- Oklahoma's local sales tax is OTC-administered and collected by material vendors at the point of sale, not assessed by the permitting authority at permit issuance.

Hail reports near Jenks, OK

Reports, last 24 months
44
Largest, last 24 months
2.00 in May 19, 2025
Most recent
Aug 21, 2026 1.00 in
Reports, last 5 years
107
5 most recent reports, last 5 years
DateHail sizeDistance
Aug 21, 20261.00 in5 mi WNW
Jun 1, 20261.00 in10 mi NNE
May 8, 20261.00 in10 mi NNE
May 8, 20261.00 in10 mi SSW
Apr 28, 20261.00 in7 mi N

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Jenks, OK (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.

Working an insurance claim in Jenks, OK? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Jenks, OK pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Jenks, OK

Is ice & water shield required in Jenks, OK?

Yes. A 36-inch-wide ice barrier IS required in all valleys ("installed in all valleys, run the length of the valley, and centered on the valley") and at all changes in roof pitch where the lower roof has a lower pitch than the upper roof -- unconditional requirements added to IRC Sec. 905.1.2 by the OUBCC 2018 IRC Permanent Rule, "the statewide minimum code for residential building construction... pursuant to 59 O.S. Sec. 1000.23." Jenks Sec. 4-1-1 through 4-1-8 contains no local amendment touching Sec. 905.1.2 or any other roofing provision, and no local climate-design table addressing the eave ice-damming trigger was found, so only the unconditional valley and pitch-change requirement is stated here.

Is drip edge required in Jenks, OK?

Yes. Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Jenks Code of Ordinances Sec. 4-1-1 "Adoption of Codes" adopts the 2018 IRC "as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC) as if fully set out at length herein" -- confirmed (this record's existing roof_layer_limit and deck_sheathing_requirements fields) by a full read of Sec. 4-1-1 through 4-1-8, none of which addresses any Chapter 9 Roof Assemblies provision. Oklahoma's operative text is therefore the OUBCC 2018 IRC Permanent Rule, whose amended R905.2.8.5 requires a drip edge at eaves and rake edges (with a shingle-mold exception).

Can you roof over an existing roof in Jenks, OK?

Jenks Code of Ordinances Sec. 4-1-1(A) "Adoption of Codes" adopts the 2018 IRC "as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC) as if fully set out at length herein," with no Jenks-specific amendment to IRC Chapter 9 anywhere in Article 1 (Building Code and Regulations) -- confirmed by reading Sec. 4-1-1 through 4-1-8 in full; none addresses roofing/recover. The governing text is therefore the OUBCC's own statewide R908.3.1.1: "A roof re-cover shall not be permitted where any of the following conditions occur: 1. Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. 2. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. 3. Where the existing roof has two or more applications of any type of roof covering. 4. Where the existing roof has one or more application of asphalt shingles additional applications of asphalt shingles shall not be permitted." (OAC 748:20-6-14(13)).

What building code does Jenks, OK use?

Jenks Code of Ordinances Sec. 4-1-1(A) ("Adoption of Codes"), as last amended by Ord. No. 1613, § I (4-18-2023), adopts the "2018 International Residential Code for One and Two Family Dwellings and Townhouses," together with the 2018 editions of the International Building, Existing Building, Fire, Plumbing, Mechanical and Fuel Gas Codes and the 2017 National Electrical Code, "all as amended and modified by the Oklahoma Uniform Building Code Commission (OUBCC)." Note that the city's Adopted Building Codes webpage has not been updated to match and still lists the 2015 International Residential Code with an effective date of April 5, 2022; the codified section was amended a year later and is the controlling instrument.