Permitting Authorities / City of Del City - Community Development Department (Permits & Inspections)

Do you need a permit to replace a roof in Del City, OK?

Adopted code

City of Del City - Community Development Department (Permits & Inspections)

Yes — a permit is required to replace a roof in Del City, OK, issued by City of Del City - Community Development Department (Permits & Inspections). The Miscellaneous Building Permit Application Instructions state contractor licensing terms by trade: "Fence contractors must be licensed with the City of Del City," "Concrete contractors must be licensed and bonded with the City," and "Contractors engaging in electrical, mechanical, and plumbing work must hold valid state and city licenses." The separate Plumbing/Electrical/Mechanical permit application states applicants "MUST HAVE A VALID CONTRACTOR LICENSE WITH THE STATE OF OKLAHOMA" and "MUST HAVE A VALID CONTRACTOR LICENSE WITH THE CITY OF DEL CITY," and that "THE CITY OF DEL CITY REQUIRES EVERYONE ON THE JOBSITE TO HAVE A VALID LICENSE WITH THE CITY OF DEL CITY." Neither document names roofing contractors specifically. Permits obtained under this process "are valid for 180 days upon issuance and become null and void if work or construction authorized is not ready for initial inspection within 180 days, or if construction or work is suspended or abandoned for a period of 30 days any time after work commences.".

Jurisdiction
City of Del City, Oklahoma
Jurisdiction type
city
Address
3701 SE 15th Street, Del City, OK 73115
Contact
Roofing permit required
Required
Contractor registration required
Permit process note
The Miscellaneous Building Permit Application Instructions state contractor licensing terms by trade: "Fence contractors must be licensed with the City of Del City," "Concrete contractors must be licensed and bonded with the City," and "Contractors engaging in electrical, mechanical, and plumbing work must hold valid state and city licenses." The separate Plumbing/Electrical/Mechanical permit application states applicants "MUST HAVE A VALID CONTRACTOR LICENSE WITH THE STATE OF OKLAHOMA" and "MUST HAVE A VALID CONTRACTOR LICENSE WITH THE CITY OF DEL CITY," and that "THE CITY OF DEL CITY REQUIRES EVERYONE ON THE JOBSITE TO HAVE A VALID LICENSE WITH THE CITY OF DEL CITY." Neither document names roofing contractors specifically. Permits obtained under this process "are valid for 180 days upon issuance and become null and void if work or construction authorized is not ready for initial inspection within 180 days, or if construction or work is suspended or abandoned for a period of 30 days any time after work commences."
Inspection requirements
"Inspections are required as provided for in the City's adopted codes, inspections must be arranged at least 48 hours in advance, scheduled and performed on the basis of need and based on the nature of the work being inspected, and failed inspections may lead to re-inspection fees."
Adopted code
The Miscellaneous Building Permit Application Instructions state: "The City's current Adopted codes and standards include: 2015 International Residential Code, 2015 International Property Maintenance Code, 2015 International Mechanical Code, 2015 International Plumbing Code, 2015 International Fuel Gas Code, 2015 International Existing Building Code, 2015 International Private Sewage Disposal Code, 2015 International Pool and Spa Code, 2014 NFPA 70: The National Electrical Code, 2015 International Energy Conservation Code, 2015 International Fire Code, 2015 International Wildland-Urban Interface Code, 2015 NFPA 101 Life Safety Code, 2015 NFPA 13/13D/13R & NFPA 72." The document adds: "Additional requirements can be found in Chapter 5 of the Del City Code of Ordinances, accessible at http://www.municode.com."
Drip edge
Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Del City's adopted codes and its Code of Ordinances Sec. 5-21 (Ord. No. 1388, Sec. 2, 2-6-17) put the city on the 2015 IRC family, NOT the 2018 IRC -- a materially different vintage from Broken Arrow, Mustang, Jenks, and Oklahoma County, which are all 2018-IRC jurisdictions governed by the OUBCC's 2018 IRC Permanent Rule. The Oklahoma Uniform Building Code Commission issued a SEPARATE, distinct Permanent Rule specific to the 2015 IRC vintage (Title 748, Chapter 20, Subchapter 5 -- "the statewide minimum code for residential construction... pursuant to 59 O.S. Sec. 1000.23," which "may only be amended or altered by other jurisdictions pursuant to Oklahoma law"). That 2015-vintage rule, Sec. 748:20-5-11.1(2), amends R905.2.8.5 to read: "A drip edge shall be provided at eaves and rake edges of shingle roofs. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Drip edges shall extend not less than 1/4 inch (6.4 mm) below the roof sheathing and extend up back onto the roof deck not less than 2 inches (51 mm)... Exception: If a nominal 1 inch by 2 inch (25 mm by 51 mm) shingle mold is used, attached to the fascia and the starter course of shingles is extended a minimum of 1/4 inch (6.35 mm) and not more than 1 inch (25 mm) then a metal drip edge is not required." Del City's own Sec. 5-21 (all seven numbered amendment items enacted by Ord. No. 1388) does not touch Chapter 9 Roof Assemblies at all -- no R905 provision of any kind appears in its amendment list -- so this state-minimum requirement stands unamended in Del City. About drip edge
Impact-resistant roofing
Not required — The City of Del City's Code of Ordinances, Chapter 5 "Buildings and Building Regulations," Article II "Building and Residential Codes," Section 5-21 "Residential Code" (Ord. No. 1388, Section 2, adopted February 6, 2017) adopts "the document known as the 2015 International Residential Code" as the city's Residential Code and lists every local amendment item by item: Section R101.1 (jurisdiction name inserted), Section R105.2 (certain permit exceptions deleted), Section R112 deleted, Section R113 deleted, a supplemental flood-hazard clause, Table R301.2(1) to be completed per project, and Section P2603.5.1 (dimension inserted). Sections 5-20 (Building Code) and 5-22 (Existing Building Code) were also read in full for completeness. None of these amendment items touches IRC Chapter 9 (Roof Assemblies); the chapter is adopted unamended. No UL 2218, Class 4, or hail-impact provision appears anywhere in Chapter 5. The Oklahoma Uniform Building Code Commission's IRC 2015 Permanent Rule (OAC Title 748, Ch. 20, Subch. 5, Section 748:20-5-11.1, 3 Chapter 9 modifications), which governs by default where Del City is silent, likewise contains no impact-resistance provision. Corroborated by the city's Miscellaneous Building Permit Application Instructions, which list the "2015 International Residential Code" among the city's currently adopted codes and point to Chapter 5 of the Code of Ordinances for additional requirements.
Wind design criteria
Del City publishes NO fixed citywide climatic/geographic design table. Its own Code of Ordinances Sec. 5-21 (Ord. No. 1388, Sec. 2, 2-6-17), amendment item 6, directs that IRC Table R301.2(1) "is to be completed as needed on a project-specific basis by a registered design professional and submitted with construction documents." In practice: the design wind speed (and every other Table R301.2(1) criterion) for a Del City project lives in that project's own stamped construction documents, not in a citywide ordinance value — a bidder or adjuster should request it from the project's registered design professional rather than expect a single Del City figure.
Roof layer limit / recover
Del City's own Code of Ordinances Sec. 5-21 (Ord. No. 1388, Sec. 2, 2-6-17, all seven numbered amendment items) does not amend IRC Chapter 9 Roof Assemblies -- no R908 provision appears anywhere in its amendment list -- so the OUBCC's 2015 IRC Permanent Rule (Title 748, Chapter 20, Subchapter 5, Sec. 748:20-5-11.1(3) -- the statewide minimum code for residential construction pursuant to 59 O.S. Sec. 1000.23 that governs Del City's own 2015 IRC vintage, as distinct from the 2018 IRC Permanent Rule that governs Oklahoma jurisdictions on the 2018 edition) governs directly: "R908.3.1.1. Roof re-cover. A roof re-cover shall not be permitted where any of the following conditions occur: (A) Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. (B) Where the existing roof covering is slate, clay, cement or asbestos-cement tile. (C) Where the existing roof has two or more applications of any type of roof covering. (D) Where the existing roof has one or more application of asphalt shingles additional applications of asphalt shingles shall not be permitted."
Deck & sheathing requirements
Del City's own Code of Ordinances Sec. 5-21 (Ord. No. 1388, Sec. 2, 2-6-17) does not amend R905.2.1 -- no R905 provision of any kind appears in its amendment list -- so the OUBCC's 2015 IRC Permanent Rule (Sec. 748:20-5-11.1(1), the statewide minimum code for Del City's own 2015 IRC vintage pursuant to 59 O.S. Sec. 1000.23) governs directly: "R905.2.1 Sheathing requirements. Asphalt shingles shall be fastened to solidly sheathed decks in accordance with Section R803 or to the asphalt shingles manufacturer's installation instructions."
Sales & use tax
Combined rate 9% inside Del City limits (state 4.5% + City of Del City 4.50% + Oklahoma County 0% -- Oklahoma County levies no county sales tax). The OTC rate chart lists only one jurisdiction code for Del City (COPO 5505, Oklahoma County), so the combined rate does not vary by address within the city. Oklahoma taxes roofing contractors as consumers/users: they pay sales tax on materials, supplies, and equipment at the point of purchase from the vendor, and do not separately charge the homeowner sales tax on labor or the finished job (Oklahoma Tax Commission Rule OAC 710:65-7-13(a): "Contractors are defined by statute as consumer/users and must pay sales tax on all taxable services and tangible personal property, including materials, supplies, and equipment purchased to develop, repair, alter, remodel, and improve real property."). No construction use tax collected at building-permit issuance was found in OTC or city sources -- Oklahoma's local sales tax is OTC-administered and collected by material vendors at the point of sale, not assessed by the permitting authority at permit issuance.

The permitting authority for the City of Del City. The Community Development Department's Permits & Inspections division issues residential and commercial building, plumbing, electrical, and mechanical permits for construction within the city and enforces the city's adopted 2015 International Codes.

Working an insurance claim in Del City, OK? Everything on this page — drip edge, ice & water shield, inspections, Class 4 rules — formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF) — one page, free.

Buy this jurisdiction's pack — $12 Delivered by email within minutes.

Questions about the Del City, OK pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions — Del City, OK

Do you need a permit to replace a roof in Del City, OK?

Required.

Is drip edge required?

Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Del City's adopted codes and its Code of Ordinances Sec. 5-21 (Ord. No. 1388, Sec. 2, 2-6-17) put the city on the 2015 IRC family, NOT the 2018 IRC -- a materially different vintage from Broken Arrow, Mustang, Jenks, and Oklahoma County, which are all 2018-IRC jurisdictions governed by the OUBCC's 2018 IRC Permanent Rule. The Oklahoma Uniform Building Code Commission issued a SEPARATE, distinct Permanent Rule specific to the 2015 IRC vintage (Title 748, Chapter 20, Subchapter 5 -- "the statewide minimum code for residential construction... pursuant to 59 O.S. Sec. 1000.23," which "may only be amended or altered by other jurisdictions pursuant to Oklahoma law"). That 2015-vintage rule, Sec. 748:20-5-11.1(2), amends R905.2.8.5 to read: "A drip edge shall be provided at eaves and rake edges of shingle roofs. Adjacent segments of drip edge shall be overlapped not less than 2 inches (51 mm). Drip edges shall extend not less than 1/4 inch (6.4 mm) below the roof sheathing and extend up back onto the roof deck not less than 2 inches (51 mm)... Exception: If a nominal 1 inch by 2 inch (25 mm by 51 mm) shingle mold is used, attached to the fascia and the starter course of shingles is extended a minimum of 1/4 inch (6.35 mm) and not more than 1 inch (25 mm) then a metal drip edge is not required." Del City's own Sec. 5-21 (all seven numbered amendment items enacted by Ord. No. 1388) does not touch Chapter 9 Roof Assemblies at all -- no R905 provision of any kind appears in its amendment list -- so this state-minimum requirement stands unamended in Del City..

Do roofing contractors need a license or registration in Del City, OK?

Required.

What building code does Del City, OK use?

The Miscellaneous Building Permit Application Instructions state: "The City's current Adopted codes and standards include: 2015 International Residential Code, 2015 International Property Maintenance Code, 2015 International Mechanical Code, 2015 International Plumbing Code, 2015 International Fuel Gas Code, 2015 International Existing Building Code, 2015 International Private Sewage Disposal Code, 2015 International Pool and Spa Code, 2014 NFPA 70: The National Electrical Code, 2015 International Energy Conservation Code, 2015 International Fire Code, 2015 International Wildland-Urban Interface Code, 2015 NFPA 101 Life Safety Code, 2015 NFPA 13/13D/13R & NFPA 72." The document adds: "Additional requirements can be found in Chapter 5 of the Del City Code of Ordinances, accessible at http://www.municode.com."