Permitting Authorities / Town of Vail Building Department - Community Development

Do you need a permit to replace a roof in Vail, CO?

Adopted code

Town of Vail Building Department - Community Development

Yes — a permit is required to replace a roof in Vail, CO, issued by Town of Vail Building Department - Community Development. Any exterior work on a structure, including reroofing, must first obtain Design Review Board approval before a permit is submitted. The Design Review Board must find the proposed roofing material satisfactory in general appearance, quality over time, architectural style, design, color and texture, and compatible with the structure, site, surrounding structures, and overall character of the Town of Vail.

Jurisdiction
Town of Vail, Colorado
Jurisdiction type
city
Address
Vail, CO
Contact
  • url: https://www.vail.gov/government/departments/community-development/building-department
Roofing permit required
Required
Contractor registration required
Required
Registration details
  • license: All contractors engaged in construction work, including repairs, alterations, and renovations of any building or structure, must be registered under Section 4-7-2 of the Vail Town Code prior to undertaking any construction work or applying for any type of permit. Contractors must provide proof of competency through a passing score on an ICC trade-specific national exam or an accepted equivalent (B.E.S.T. certification, Denver Supervisor Certification, or a state exam or license from another state).
Permit process note
Any exterior work on a structure, including reroofing, must first obtain Design Review Board approval before a permit is submitted. The Design Review Board must find the proposed roofing material satisfactory in general appearance, quality over time, architectural style, design, color and texture, and compatible with the structure, site, surrounding structures, and overall character of the Town of Vail.
Adopted code
2024 ICC editions, adopted by reference at Vail Town Code Title 10, Chapter 1, Sec. 10-1-1, read from the codified Town Code (current through Ord. 5, Series 2026, passed May 5, 2026): the 2024 International Building Code (Appendices B, E, G, J, K and O), 2024 International Residential Code (Appendices BE, BO and AA), 2024 International Fire Code, 2024 International Energy Conservation Code (Appendices CA and RA), 2024 International Plumbing Code, 2024 International Fuel Gas Code, 2024 International Mechanical Code, 2024 International Existing Building Code, the 2023 National Electrical Code, and the 1997 Uniform Code for the Abatement of Dangerous Buildings. The section's credit line "(Ord. 8(2022) Sec. 1; Ord. 13(2024) Sec. 1)" records the history: Ord. 8 (2022) adopted the 2021 editions and Ord. 13 (2024) moved the adoptions to the 2024 editions, which Town materials list as effective January 1, 2026. Older Town pages still describing the 2021 adoption are superseded.
Impact-resistant roofing
Not required — The Vail Town Code, Title 10, Chapter 1, Building Codes, was read in full. Section 10-1-1, enacted by Ordinance 8 of 2022 and Ordinance 13 of 2024, adopts by reference the 2024 editions of the International Building, Residential, Fire, Energy Conservation, Plumbing, Fuel Gas, Mechanical and Existing Building Codes, the 2023 National Electrical Code and the 1997 Uniform Code for the Abatement of Dangerous Buildings, and Sections 10-1-2 through 10-1-11 carry the Town's amendments to each, all read. The roofing amendments are extensive and are directed at fire and snow: Building Code Section 1505.1 and Residential Code Section R902.1 as amended require every roof covering and roof assembly to be Class A and prohibit wood shakes and shingles, a nonconforming roof may be repaired or replaced only once and only up to 25 percent of its area before the whole covering must be brought into conformance, a new Chapter 7A imposes ignition-resistant construction in the Town's wildland-urban interface areas, ice barriers must cover all roof surfaces, snow-retention devices are required on new roof assemblies, and roof snow loads are set at 100 and 80 pounds per square foot. A Class A rating is a fire classification tested to ASTM E108 or UL 790 and is independent of impact rating; neither the adopted codes nor any Town amendment requires impact-resistant roof coverings or names a UL 2218 or Class 4 standard. The only statewide instrument reaching reroofing is the Colorado Wildfire Resiliency Code, 8 CCR 1507-39, effective July 1, 2026 in areas designated wildland-urban interface under that code, which requires a Class A roof covering tested to ASTM E108 or UL 790 where 25 percent or more of the roof surface is replaced, at Sections 101.6 and 403.2; that is a fire classification independent of impact rating, and the code sets no impact-resistance requirement.
Sales & use tax
9.4% combined effective 1/1/2023 (state 2.9% + Eagle County 1.0% + Eagle County Transportation 0.5% + Regional Transportation Authority 0.5% + Town of Vail 4.5%). Home-rule, self-collected by the Town. The Town separately imposes a 4% use tax on construction and/or building materials, collected at the time of building-permit issuance: 50% of the construction valuation is deemed construction/building materials subject to the 4% use tax, the first $10,000 of construction valuation is exempt, and the use-tax charge is separately stated on the building permit.

The building permit authority for the Town of Vail, Colorado. Reroofing is exterior work that requires Design Review Board approval of the roofing material before a building permit application may be submitted, and all contractors must be registered with the town before undertaking any construction work or applying for any type of permit.

Working an insurance claim in Vail, CO? Everything on this page — drip edge, ice & water shield, inspections, Class 4 rules — formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF) — one page, free.

Buy this jurisdiction's pack — $12 Delivered by email within minutes.

Questions about the Vail, CO pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Free instant roof estimate — Vail, CO

Ballpark your replacement in 20 seconds. No phone call required to see the number.

Roofing questions — Vail, CO

Do you need a permit to replace a roof in Vail, CO?

Required.

Do roofing contractors need a license or registration in Vail, CO?

Required. All contractors engaged in construction work, including repairs, alterations, and renovations of any building or structure, must be registered under Section 4-7-2 of the Vail Town Code prior to undertaking any construction work or applying for any type of permit. Contractors must provide proof of competency through a passing score on an ICC trade-specific national exam or an accepted equivalent (B.E.S.T. certification, Denver Supervisor Certification, or a state exam or license from another state)..

What building code does Vail, CO use?

2024 ICC editions, adopted by reference at Vail Town Code Title 10, Chapter 1, Sec. 10-1-1, read from the codified Town Code (current through Ord. 5, Series 2026, passed May 5, 2026): the 2024 International Building Code (Appendices B, E, G, J, K and O), 2024 International Residential Code (Appendices BE, BO and AA), 2024 International Fire Code, 2024 International Energy Conservation Code (Appendices CA and RA), 2024 International Plumbing Code, 2024 International Fuel Gas Code, 2024 International Mechanical Code, 2024 International Existing Building Code, the 2023 National Electrical Code, and the 1997 Uniform Code for the Abatement of Dangerous Buildings. The section's credit line "(Ord. 8(2022) Sec. 1; Ord. 13(2024) Sec. 1)" records the history: Ord. 8 (2022) adopted the 2021 editions and Ord. 13 (2024) moved the adoptions to the 2024 editions, which Town materials list as effective January 1, 2026. Older Town pages still describing the 2021 adoption are superseded.