Permitting Authorities / Colorado / Town of Avon - Community Development Department (Building Division)

Do you need a permit to replace a roof in Avon, CO?

Adopted code

Town of Avon - Community Development Department (Building Division)

Yes, a permit is required to replace a roof in Avon, CO, issued by Town of Avon - Community Development Department (Building Division). A replacement/new roof permit is required anytime a roof is repaired or replaced; depending on the extent of work, the permit may also need to go through planning review. Applications are submitted through the Cloudpermit portal.

Roof code checklist: Avon, CO

ItemAnswerCode citeSourceVerified
Permit to replace a roofYesavon.org2026-10-06
Repair permit thresholdNot published
Layer limit / roof-overNot published
Deck & sheathingNot published
Drip edgeYesR905.2.8.5library.municode.com2026-07-31
Ice & water shieldYeslibrary.municode.com2026-07-31
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNolibrary.municode.com2026-07-31
Wind design criteriaPublishedlibrary.municode.com2026-07-31
Adopted codePublishedavon.org2026-07-15
Contractor license / registrationYesavon.org2026-07-15
Sales & use taxPublishedavon.org2026-07-31

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Town of Avon, Colorado
Jurisdiction type
city
Address
Avon, CO
Contact
  • url: https://www.avon.org/151/Building
  • phone: 970-748-4030
Permit portal
Roofing permit required
Required
Contractor registration required
Required
Registration details
  • license: Contractors must be licensed with the Town of Avon to operate within town limits. Licenses are valid for one year and are managed through the Cloudpermit portal; applicants without employees must complete a Workers Compensation Insurance Waiver form.
Permit process note
A replacement/new roof permit is required anytime a roof is repaired or replaced; depending on the extent of work, the permit may also need to go through planning review. Applications are submitted through the Cloudpermit portal.
Adopted code
The Town of Avon has adopted the 2021 International Building Code, 2021 International Residential Code, 2021 International Energy Conservation Code, 2021 International Plumbing Code, 2021 International Fuel Gas Code, 2021 International Mechanical Code, 2021 International Fire Code (with local amendments), 2021 International Swimming Pool and Spa Code, 2021 International Property Maintenance Code, 2021 International Wildland-Urban Interface Code, the 2023 National Electric Code, and ICC A117.1-2017 for accessible and useable buildings.
Drip edge
Required — Not separately amended by the Town of Avon. Sec. 15.10.020 states: "The 2021 International Residential Code is amended and changed as described in Sections 15.10.030 through 15.10.110 of this Chapter" -- a closed, self-declared list of nine amended sections (R101, R104, R108, R109, R110, R112, R114, Table R301.2, Appendix AT), none of which touch R905.2.8.5, so the base IRC drip-edge requirement stands as adopted code. About drip edge
Ice & water shield
Required — Town of Avon Municipal Code Sec. 15.10.100, the amended Table R301.2, lists "Ice Barrier Underlayment Required = YES, 100%" as the townwide determination. About ice & water barrier
Impact-resistant roofing
Not required — Town of Avon Municipal Code Chapter 15.10, the town's complete amendment chapter to the 2021 International Residential Code, was read in full (all 16 sections; Sec. 15.10.020 confirms the amendment scope is closed to Sections 15.10.030-15.10.110) and contains no provision addressing impact-resistant roofing, UL 2218, Class 4 shingles, or hail.
Wind design criteria
Town of Avon Municipal Code Sec. 15.10.100 amends Table R301.2 of the 2021 International Residential Code to read: "Ground and Snow Loads (psf) = <= 8,200 ft.: 75; > 8,200 ft.: 90; Wind Design Speed (mph) = 115; Topographical effects = No; Special wind region = No; Wind borne debris zone = No; Seismic Design Category = B; Weathering = SEVERE; Frost line depth = 48''; Termite = None to Slight; Flood Hazards = Slight; Air Freezing Index = 2500; Mean Annual Temp = 37.4." Ground snow load is elevation-tiered rather than a single town-wide figure.
Sales & use tax
9.69% combined (state 2.9% + Eagle County 1.5% + Eagle Valley RTA (Rural Transit Authority) 0.5% + Eagle River Fire Protection District 0.79% + Town of Avon 4%). Home-rule, self-collected by the Town (via MuniRevs). The Town separately imposes its own 4% use tax on construction materials: "All materials delivered to a job site located within the Town of Avon will be subject to the Town's 4% use tax," administered directly by the Town, distinct from and additional to the sales-tax mechanism.

The building permit authority for the Town of Avon, Eagle County. Requires a permit for roof repair or replacement, requires contractors to be licensed with the Town, and has adopted the 2021 editions of the International Building, Residential, and related codes.

No NOAA hail reports within 10 miles of Avon, CO in the last 5 years (data through Oct 7, 2026).

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Avon, CO (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.

Working an insurance claim in Avon, CO? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Avon, CO pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Free instant roof estimate — Avon, CO

Ballpark your replacement in 20 seconds. No phone call required to see the number.

Roofing questions: Avon, CO

Do you need a permit to replace a roof in Avon, CO?

Yes, a permit is required to replace a roof in Avon, CO.

Is ice & water shield required in Avon, CO?

Yes. Town of Avon Municipal Code Sec. 15.10.100, the amended Table R301.2, lists "Ice Barrier Underlayment Required = YES, 100%" as the townwide determination.

Is drip edge required in Avon, CO?

Yes. Not separately amended by the Town of Avon. Sec. 15.10.020 states: "The 2021 International Residential Code is amended and changed as described in Sections 15.10.030 through 15.10.110 of this Chapter" -- a closed, self-declared list of nine amended sections (R101, R104, R108, R109, R110, R112, R114, Table R301.2, Appendix AT), none of which touch R905.2.8.5, so the base IRC drip-edge requirement stands as adopted code.

Do roofing contractors need a license or registration in Avon, CO?

Yes. Contractors must be licensed with the Town of Avon to operate within town limits. Licenses are valid for one year and are managed through the Cloudpermit portal; applicants without employees must complete a Workers Compensation Insurance Waiver form.

What building code does Avon, CO use?

The Town of Avon has adopted the 2021 International Building Code, 2021 International Residential Code, 2021 International Energy Conservation Code, 2021 International Plumbing Code, 2021 International Fuel Gas Code, 2021 International Mechanical Code, 2021 International Fire Code (with local amendments), 2021 International Swimming Pool and Spa Code, 2021 International Property Maintenance Code, 2021 International Wildland-Urban Interface Code, the 2023 National Electric Code, and ICC A117.1-2017 for accessible and useable buildings.