Permitting Authorities / Colorado / Town of Basalt Building Department

Do you need a permit to replace a roof in Basalt, CO?

Adopted code

Town of Basalt Building Department

The building permit authority for the Town of Basalt, Colorado, which spans Eagle and Pitkin counties. Roofing contractors must hold a B.E.S.T. Card roofing credential or an approved reciprocal credential, and any person or business performing construction work within town limits must obtain a Town of Basalt Contractor License. Building permit applications are processed through the CloudPermit online portal.

Roof code checklist: Basalt, CO

ItemAnswerCode citeSourceVerified
Permit to replace a roofNot published
Repair permit thresholdNot published
Layer limit / roof-overNot published
Deck & sheathingNot published
Drip edgeYesR905.2.8.5library.municode.com2026-08-03
Ice & water shieldYeslibrary.municode.com2026-08-03
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNolibrary.municode.com2026-08-03
Wind design criteriaPublishedlibrary.municode.com2026-08-03
Adopted codePublishedbasalt.net2026-07-15
Contractor license / registrationYesbasalt.net2026-07-15
Sales & use taxPublishedtax.colorado.gov2026-08-27

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Town of Basalt, Colorado
Jurisdiction type
city
Address
101 Midland Avenue, Basalt, CO 81621
Contact
  • url: https://www.basalt.net/132/Building
  • phone: 970-927-4702
Permit portal
Contractor registration required
Required
Registration details
  • license: Any person or business performing construction work within the Town of Basalt must obtain a Town of Basalt Contractor License. Roofing contractors must hold a B.E.S.T. Card roofing credential (or an approved reciprocal credential), issued to the individual test-taker rather than the company. B.E.S.T. testing is not currently offered in Basalt; roofing contractors may test through the City of Aspen, Town of Snowmass Village, City of Glenwood Springs, or Town of Silt.
Permit process note
Building permit applications are submitted through the CloudPermit online portal. As of May 2017 the Building Department does not conduct inspections or site visits on Mondays or Fridays.
Adopted code
The Town of Basalt has adopted the 2021 ICC codes (IBC/IRC), the 2023 National Electrical Code, and the 2024 Sustainable Building Regulations I and II amendments.
Drip edge
Required — Not separately amended by the Town of Basalt. Municipal Code § 18-22's IRC amendment list is a single continuously-numbered sequence, items (1) through at least (24), running from R101.1 through E3401.1 (Electrical); it jumps directly from item (13) (Section R506.2.3, concrete floor vapor retarder) to item (14) (Section R1001.1, masonry fireplaces), with nothing addressing Chapters 7-9 (walls, roof-ceiling construction, roof assemblies) in between -- confirming R905, R907, and R908, including R905.2.8.5, are untouched. § 18-22 states adoption of the IRC "is subject to the following deletions, amendments, additions, and modifications," so the base 2021 IRC drip-edge requirement stands as adopted code where not listed. About drip edge
Ice & water shield
Required — Basalt's amended Table R301.2(1) (Municipal Code § 18-22, item (7)) prints "Ice Barrier Underlayment Required: Yes." About ice & water barrier
Impact-resistant roofing
Not required — Municipal Code § 18-22's IRC amendment list, items (1) through at least (24) (a single continuously-numbered, exhaustive sequence), was read in full and contains no UL 2218, Class 4, or impact-resistance provision anywhere; the full Chapter 18 Municode content (Building, Residential, Fuel Gas, Fire, and related articles) was also grepped for "UL 2218" and "Class 4" with no hits.
Wind design criteria
Basalt Municipal Code § 18-22 (Adoption of the International Residential Code, 2021 edition, subject to amendments), item (7), amends and prints Table R301.2(1) Climatic and Geographic Design Criteria: Ground Snow Load "55 psf"; Wind Design Speed "115" mph; Topographic effects "No"; Special wind region "No"; Windborne debris zone "No"; Seismic Design Category "B"; Weathering "Severe"; Frost line depth "36""; Termite "None to Slight"; Ice Barrier Underlayment Required "Yes"; Flood Hazards "Ord# 25 series 2000"; Air Freezing Index "2500 Deg Day (F)"; Mean Annual Temp "44°." (Verified against the Town's own June 2023 first-reading ordinance exhibit, rendered at 300dpi and read directly from the table image; the Town's Building page confirms these 2023 amendments "were approved at second reading on June 27, 2023," and the identical table is reproduced verbatim in the current Municode-codified text, Supp. No. 28, codified through Ordinance No. 08-2025.)
Sales & use tax
Basalt spans Eagle and Pitkin Counties, and the combined rate differs by which county a given address sits in: Eagle County portion, 8.20% (state 2.9% + Eagle County 1.50% + Town of Basalt 3% + Roaring Fork Regional Transportation Authority (RFTA) 0.80%). Pitkin County portion, 9.30% (state 2.9% + Pitkin County 2.60% + Town of Basalt 3% + RFTA 0.80%). Per CO DOR DR 1002 (a 2019/2020-vintage publication), Basalt is state-collected: its "State-Collected City Sales Taxes" table prints Basalt's row as "Basalt / Eagle, Pitkin / 3% / 3.33% [service fee] / None [use tax]," Eagle County's rate as "1.50%1" (footnote 1: "Rate includes 0.5% Mass Transit System (MTS) in Eagle and Pitkin Counties"), and a Pitkin-County row specifically labeled "Pitkin (in Basalt) / 2.60%1" -- lower than Pitkin County's general 3.60%1 rate elsewhere in the county. DR 1002's Regional Transportation Authority (RTA) table separately lists "Roaring Fork / Basalt and New Castle city limits / 0.80%," applicable countywide-boundary-independent since it is keyed to Town limits, not county. Re-verified 2026-08-27 against the January 2026 edition of Colorado Department of Revenue form DR 1002, read from a rendered image of its tables rather than from extracted text: the state, county and city figures above match that edition exactly. Where the text above names the June 19, 2019 revision of DR 1002, that describes the edition the figure was originally taken from and is not a current citation.

Hail reports near Basalt, CO

Reports, last 24 months
0
Largest, last 24 months
None
Most recent
None in 24 months
Reports, last 5 years
1
Most recent report, last 5 years
DateHail sizeDistance
Aug 1, 20231.00 in9 mi WNW

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Basalt, CO (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.

Working an insurance claim in Basalt, CO? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Basalt, CO pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Free instant roof estimate — Basalt, CO

Ballpark your replacement in 20 seconds. No phone call required to see the number.

Roofing questions: Basalt, CO

Is ice & water shield required in Basalt, CO?

Yes. Basalt's amended Table R301.2(1) (Municipal Code § 18-22, item (7)) prints "Ice Barrier Underlayment Required: Yes."

Is drip edge required in Basalt, CO?

Yes. Not separately amended by the Town of Basalt. Municipal Code § 18-22's IRC amendment list is a single continuously-numbered sequence, items (1) through at least (24), running from R101.1 through E3401.1 (Electrical); it jumps directly from item (13) (Section R506.2.3, concrete floor vapor retarder) to item (14) (Section R1001.1, masonry fireplaces), with nothing addressing Chapters 7-9 (walls, roof-ceiling construction, roof assemblies) in between -- confirming R905, R907, and R908, including R905.2.8.5, are untouched. § 18-22 states adoption of the IRC "is subject to the following deletions, amendments, additions, and modifications," so the base 2021 IRC drip-edge requirement stands as adopted code where not listed.

Do roofing contractors need a license or registration in Basalt, CO?

Yes. Any person or business performing construction work within the Town of Basalt must obtain a Town of Basalt Contractor License. Roofing contractors must hold a B.E.S.T. Card roofing credential (or an approved reciprocal credential), issued to the individual test-taker rather than the company. B.E.S.T. testing is not currently offered in Basalt; roofing contractors may test through the City of Aspen, Town of Snowmass Village, City of Glenwood Springs, or Town of Silt.

What building code does Basalt, CO use?

The Town of Basalt has adopted the 2021 ICC codes (IBC/IRC), the 2023 National Electrical Code, and the 2024 Sustainable Building Regulations I and II amendments.