Permitting Authorities / City of Moore - Building Permits & Inspections (Community Development Department)

Do you need a permit to replace a roof in Moore, OK?

Adopted code

City of Moore - Building Permits & Inspections (Community Development Department)

Yes — a permit is required to replace a roof in Moore, OK, issued by City of Moore - Building Permits & Inspections (Community Development Department). The city's Building Permits & Inspections page states that permits are required for "most commercial and residential remodels, additions or improvements, as well as all new construction," and directs applicants to contact the Inspections Department if uncertain whether a permit is needed. Same-day inspections are available by calling the department or messaging through the GovBuilt portal before 9am. The city's GovBuilt permitting portal publishes a dedicated "Roofing Permit Application" among its Building Inspections forms.

Jurisdiction
City of Moore, Oklahoma
Jurisdiction type
city
Address
301 N. Broadway, Moore, OK 73160
Contact
  • url: https://www.cityofmoore.com/departments/planning-development/building-permits-inspections
  • phone: 405-793-5051
Permit portal
Roofing permit required
Required
Contractor registration required
Registration details
  • license: Moore Municipal Code Chapter 5-10 "Roofing Contractors" (Sec. 5-1001 -- 5-1013; Ord. No. 689(10), 12-6-2010) creates a CITY registration for roofing contractors that is layered on top of, not a substitute for, state licensing. Sec. 5-1002 "Registration; Fine": "A person may not engage in the business nor act in the capacity of a roofing contractor within the city ... without a valid registration as provided in this chapter," punishable on conviction by a fine of up to $500.00. Sec. 5-1004 requires the applicant to attach "a valid approved state registration" to the city application, plus a certificate of liability insurance of "not less than $500,000.00" and proof of workers' compensation coverage (or an exemption affidavit). Registration expires annually on June 30 (Sec. 5-1007/5-1009), with a 30-day grace period, suspension for non-renewal by August 30, and revocation the following January 1 if still unrenewed. Sec. 5-1008 exempts: a property owner physically performing roofing work on his own residential/farm dwelling without a registered contractor's help; government employees acting in that capacity; and material/product suppliers who do not install. Sec. 5-1001's definitions separately exempt a "handyman ... who does not perform more than two roofing jobs per year." Sec. 5-1013 requires the roofing contractor's registration number to be disclosed on every permit application and displayed on vehicles, signage, and contracts.
Permit process note
The city's Building Permits & Inspections page states that permits are required for "most commercial and residential remodels, additions or improvements, as well as all new construction," and directs applicants to contact the Inspections Department if uncertain whether a permit is needed. Same-day inspections are available by calling the department or messaging through the GovBuilt portal before 9am. The city's GovBuilt permitting portal publishes a dedicated "Roofing Permit Application" among its Building Inspections forms.
Adopted code
The city's Building Permits & Inspections page lists 2018 editions of the International Residential Code, International Building Code, International Fire Code, International Mechanical Code, International Plumbing Code, International Fuel Gas Code, International Existing Building Code, and International Property Maintenance Code, plus the 2020 National Electrical Code, the 2018 NFPA Life Safety Code, and the 2017 ICC A117.1 Accessibility Standard, "adopted as amended by the City and Oklahoma Uniform Building Code Commission."
Drip edge
Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Oklahoma's operative text is the OUBCC 2018 IRC Permanent Rule -- "the statewide minimum code for residential building construction for one- and two-family dwellings and townhouses in Oklahoma pursuant to 59 O.S. Sec. 1000.23" -- whose amended R905.2.8.5 requires a drip edge at eaves and rake edges (with a shingle-mold exception). The City of Moore's own IRC-adoption ordinance, Municipal Code Sec. 5-204 (Adoption of the International Residential Code; most recently amended by Ord. No. 1039.23, 12-18-2023, tracing back through Ord. Nos. 724(12), 768(14), 857(17)), read in full, lists its section-by-section amendments to the adopted 2018 IRC exhaustively and does not touch R905.2 or R905.2.8.5 anywhere in that list (its only Chapter 9 amendment is to R905.1.2, ice barriers), so the state-minimum drip-edge requirement stands unamended in Moore. About drip edge
Ice & water shield
Required — Required -- and, unusually among Oklahoma jurisdictions, set by the City of Moore's OWN local amendments rather than by the state minimum. Moore's own amended IRC Table R301.2(1) (Municipal Code Sec. 5-204, table amendment codified as an image reproduction of Ord. No. 1039.23, 12-18-2023) answers the "Ice Barrier Underlayment Required" cell "Yes" (alongside: ground snow load 10 lb/ft2, wind design speed 135 mph, topographic/special-wind-region/windborne-debris all "No," seismic design category C, winter design temp 13 F, air freezing index 300, mean annual temp 60.9 F). Separately and more specifically, Moore's Sec. 5-204 directly rewrites IRC R905.1.2 itself (not merely silence/adopt-unamended): "R905.1.2 Ice barriers. In the roof valleys an ice barrier shall be installed for asphalt shingles, metal roof shingles, mineral surface roll roofing, s[l]ate and slate-type shingles, wood shingles and wood shakes. The ice barrier shall consist of not fewer than two layers of underlayment cemented together, or a self-adhering polymer modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edge of the roof surface. Exception: Detached accessory structures not containing conditioned floor area." That local text sets the valley trigger and specifies the underlayment method (two cemented layers, or a self-adhering membrane) but does not separately restate a roof-pitch-change trigger. Oklahoma's OUBCC 2018 IRC Permanent Rule -- the statewide minimum code Moore's Sec. 5-201/5-204 explicitly adopts "as amended and modified by the Oklahoma uniform building code commission pursuant to 59 O.S. Sec. 1000.23" -- additionally and unconditionally requires a 36-inch-wide ice barrier "at all change in roof pitch in which the lower roof has a lower pitch than the upper roof," a trigger Moore's own local amendment neither restates nor contradicts. Net effect in Moore: ice barrier required at eaves (per the city's own Table R301.2(1) "Yes"), in all roof valleys (per the city's own R905.1.2 text and method), and at pitch changes (per the state minimum, which Moore's own amendment does not address). About ice & water barrier
Impact-resistant roofing
Not required — City of Moore Ordinance No. 1039.23, "AN ORDINANCE AMENDING PART 5, CHAPTER 2, ARTICLE A, SECTIONS 5-201, 5-202, 5-204, 5-206, 5-207 AND 5-210; AND ARTICLE D, SECTIONS 5-251 THROUGH 5-253," passed and approved December 18, 2023, is the city's current codified building- and residential-code adoption ordinance and was read in full (23 pages, Sections 5-201 through 5-210 and 5-251 through 5-253). Section 5-204 adopts the 2018 International Residential Code as amended and modified by the Oklahoma Uniform Building Code Commission, then lists the city's own IRC amendments as 58 numbered items; of those, only one, item 27, touches Chapter 9 Roof Assemblies, amending R905.1.2 Ice barriers. No other R9-series section is amended. Section 5-204 separately adds a 12-item "adoption of residential wind code for one-to-two family dwelling," covering roof and wall sheathing fastening schedules, framing connections, hurricane clips or framing anchors at rafter-to-wall connections, and a requirement that garage doors be rated to 135 mph wind or greater -- structural wind-resistance measures, not a roof-covering material or impact-resistance standard. Section 5-202's 40-plus item amendment list to the International Building Code does not touch IBC Chapter 15 (Roof Assemblies) either. No UL 2218, Class 4, or impact-resistance provision appears anywhere in the ordinance; its only appearance of the word "hail" is in Section 5-251's definition of awnings, carports, and patio covers as structures providing shelter "from the sun, rain, snow, sleet or hail," which does not concern roof covering material. Oklahoma's OUBCC 2018 IRC Permanent Rule (OAC 748:20-6-14, "IRC (R) 2018 Chapter 9 Roof Assemblies"), the statewide floor that Section 5-204 explicitly adopts "as amended and modified by" and which Moore may exceed but not fall below, was independently confirmed to contain zero UL 2218, Class 4, or hail provisions across its 13 Chapter 9 modifications.
Wind design criteria
City of Moore Municipal Code Sec. 5-204 amends IRC Table R301.2(1) via an image reproduction embedded in the codified ordinance text (Ord. No. 1039.23, 12-18-2023): Ground Snow Load = 10 lb/ft2; Wind Design Speed = 135 mph; Wind Design Topographic effects = No; Wind Design Special Wind Region = No; Wind Design Windborne Debris Zone = No; Seismic Design Category = C; Subject to Damage From, Weathering = Moderate; Subject to Damage From, Frost Line Depth = 18 inches; Subject to Damage From, Termite = Moderate to heavy; Winter Design Temp = 13 F; Ice Barrier Underlayment Required = Yes; Flood Hazards = "Land Development Code"; Air Freezing Index = 300; Mean Annual Temp = 60.9 F. The same amendment adds a "Manual J Design Criteria" table not present in the base IRC table: Elevation 451-3,266 ft; Latitude 33.909N-36.605N; Winter Heating 11.8-25.0 F; Summer Cooling 95.0-101.8 F; Altitude Correction Factor 0.99-0.78; Indoor Design Temperature Cooling 68-70 F; Design Temperature Difference Cooling 72-75 F; Heating Temperature Difference 58.2-45.0 F; Cooling Temperature Difference 23.0-26.8 F; Wind Velocity Heating 15 mph; Wind Velocity Cooling 7.5 mph; Coincident Wet Bulb 67.5-77.4 F; Daily Range M; Winter Humidity 30%; Summer Humidity 50%-65%.
Roof layer limit / recover
City of Moore Municipal Code Sec. 5-204 (Adoption of the International Residential Code; Ord. No. 1039.23, 12-18-2023, and predecessor amending ordinances back to 1990), read in full, does not amend Chapter 9 (Roof Assemblies) of the adopted 2018 IRC beyond its one Chapter 9 amendment to R905.1.2 (ice barriers) -- no R908 provision appears anywhere in its amendment list. The operative text for roof re-cover is therefore the Oklahoma Uniform Building Code Commission's 2018 IRC Permanent Rule (OAC 748:20-6-14(13)), which amends R908.3.1.1 Roof re-cover to read: "A roof re-cover shall not be permitted where any of the following conditions occur: 1. Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing. 2. Where the existing roof covering is slate, clay, cement or asbestos-cement tile. 3. Where the existing roof has two or more applications of any type of roof covering. 4. Where the existing roof has one or more application of asphalt shingles additional applications of asphalt shingles shall not be permitted."
Deck & sheathing requirements
City of Moore Municipal Code Sec. 5-204, read in full, does not amend R905.2.1 (its only Chapter 9 amendment touches R905.1.2, ice barriers), so the operative sheathing text is the Oklahoma Uniform Building Code Commission's 2018 IRC Permanent Rule (OAC 748:20-6-14(2)), which amends R905.2.1 Sheathing requirements to read: "Asphalt shingles shall be fastened to solidly sheathed decks. Solidly sheathed decks shall be defined as sawn lumber boards or structural panels that provide a solid holding power for fasteners that do not have deficit conditions (gaps greater than those allowed by the roof covering manufacturer's installation instructions, warped, split, cracked, deteriorated or rotten boards)."
Sales & use tax
Combined rate 8.5% inside Moore city limits (state 4.5% + City of Moore 3.875% + Cleveland County 0.125%). The OTC rate chart lists only one jurisdiction code for Moore (COPO 1404, Cleveland County), so the combined rate does not vary by address within the city. Oklahoma taxes roofing contractors as consumers/users: they pay sales tax on materials, supplies, and equipment at the point of purchase from the vendor, and do not separately charge the homeowner sales tax on labor or the finished job (Oklahoma Tax Commission Rule OAC 710:65-7-13(a): "Contractors are defined by statute as consumer/users and must pay sales tax on all taxable services and tangible personal property, including materials, supplies, and equipment purchased to develop, repair, alter, remodel, and improve real property."). No construction use tax collected at building-permit issuance was found in OTC or city sources -- Oklahoma's local sales tax is OTC-administered and collected by material vendors at the point of sale, not assessed by the permitting authority at permit issuance.

The permitting authority for the City of Moore, Oklahoma. The Community Development Department's Building Permits & Inspections division issues building permits for new construction, remodels, additions and improvements, and provides inspection services, with applications and payments handled through the city's GovBuilt online portal.

Working an insurance claim in Moore, OK? Everything on this page — drip edge, ice & water shield, inspections, Class 4 rules — formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF) — one page, free.

Buy this jurisdiction's pack — $12 Delivered by email within minutes.

Questions about the Moore, OK pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions — Moore, OK

Do you need a permit to replace a roof in Moore, OK?

Required.

Is ice & water shield required in Moore, OK?

Required — Required -- and, unusually among Oklahoma jurisdictions, set by the City of Moore's OWN local amendments rather than by the state minimum. Moore's own amended IRC Table R301.2(1) (Municipal Code Sec. 5-204, table amendment codified as an image reproduction of Ord. No. 1039.23, 12-18-2023) answers the "Ice Barrier Underlayment Required" cell "Yes" (alongside: ground snow load 10 lb/ft2, wind design speed 135 mph, topographic/special-wind-region/windborne-debris all "No," seismic design category C, winter design temp 13 F, air freezing index 300, mean annual temp 60.9 F). Separately and more specifically, Moore's Sec. 5-204 directly rewrites IRC R905.1.2 itself (not merely silence/adopt-unamended): "R905.1.2 Ice barriers. In the roof valleys an ice barrier shall be installed for asphalt shingles, metal roof shingles, mineral surface roll roofing, s[l]ate and slate-type shingles, wood shingles and wood shakes. The ice barrier shall consist of not fewer than two layers of underlayment cemented together, or a self-adhering polymer modified bitumen sheet shall be used in place of normal underlayment and extend from the lowest edge of the roof surface. Exception: Detached accessory structures not containing conditioned floor area." That local text sets the valley trigger and specifies the underlayment method (two cemented layers, or a self-adhering membrane) but does not separately restate a roof-pitch-change trigger. Oklahoma's OUBCC 2018 IRC Permanent Rule -- the statewide minimum code Moore's Sec. 5-201/5-204 explicitly adopts "as amended and modified by the Oklahoma uniform building code commission pursuant to 59 O.S. Sec. 1000.23" -- additionally and unconditionally requires a 36-inch-wide ice barrier "at all change in roof pitch in which the lower roof has a lower pitch than the upper roof," a trigger Moore's own local amendment neither restates nor contradicts. Net effect in Moore: ice barrier required at eaves (per the city's own Table R301.2(1) "Yes"), in all roof valleys (per the city's own R905.1.2 text and method), and at pitch changes (per the state minimum, which Moore's own amendment does not address)..

Is drip edge required?

Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). Oklahoma's operative text is the OUBCC 2018 IRC Permanent Rule -- "the statewide minimum code for residential building construction for one- and two-family dwellings and townhouses in Oklahoma pursuant to 59 O.S. Sec. 1000.23" -- whose amended R905.2.8.5 requires a drip edge at eaves and rake edges (with a shingle-mold exception). The City of Moore's own IRC-adoption ordinance, Municipal Code Sec. 5-204 (Adoption of the International Residential Code; most recently amended by Ord. No. 1039.23, 12-18-2023, tracing back through Ord. Nos. 724(12), 768(14), 857(17)), read in full, lists its section-by-section amendments to the adopted 2018 IRC exhaustively and does not touch R905.2 or R905.2.8.5 anywhere in that list (its only Chapter 9 amendment is to R905.1.2, ice barriers), so the state-minimum drip-edge requirement stands unamended in Moore..

Do roofing contractors need a license or registration in Moore, OK?

Required. Moore Municipal Code Chapter 5-10 "Roofing Contractors" (Sec. 5-1001 -- 5-1013; Ord. No. 689(10), 12-6-2010) creates a CITY registration for roofing contractors that is layered on top of, not a substitute for, state licensing. Sec. 5-1002 "Registration; Fine": "A person may not engage in the business nor act in the capacity of a roofing contractor within the city ... without a valid registration as provided in this chapter," punishable on conviction by a fine of up to $500.00. Sec. 5-1004 requires the applicant to attach "a valid approved state registration" to the city application, plus a certificate of liability insurance of "not less than $500,000.00" and proof of workers' compensation coverage (or an exemption affidavit). Registration expires annually on June 30 (Sec. 5-1007/5-1009), with a 30-day grace period, suspension for non-renewal by August 30, and revocation the following January 1 if still unrenewed. Sec. 5-1008 exempts: a property owner physically performing roofing work on his own residential/farm dwelling without a registered contractor's help; government employees acting in that capacity; and material/product suppliers who do not install. Sec. 5-1001's definitions separately exempt a "handyman ... who does not perform more than two roofing jobs per year." Sec. 5-1013 requires the roofing contractor's registration number to be disclosed on every permit application and displayed on vehicles, signage, and contracts..

What building code does Moore, OK use?

The city's Building Permits & Inspections page lists 2018 editions of the International Residential Code, International Building Code, International Fire Code, International Mechanical Code, International Plumbing Code, International Fuel Gas Code, International Existing Building Code, and International Property Maintenance Code, plus the 2020 National Electrical Code, the 2018 NFPA Life Safety Code, and the 2017 ICC A117.1 Accessibility Standard, "adopted as amended by the City and Oklahoma Uniform Building Code Commission."