Permitting Authorities / Colorado / City of Longmont - Building Inspection Division
Do you need a permit to replace a roof in Longmont, CO?
Adopted code
City of Longmont - Building Inspection Division
Yes, a permit is required to replace a roof in Longmont, CO, issued by City of Longmont - Building Inspection Division. A permit is required to reroof a house; repairs replacing less than 100 square feet of the total roof area do not require a permit.
Roof code checklist: Longmont, CO
Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.
Jurisdiction
City of Longmont, Colorado
Contact
- url: https://longmontcolorado.gov/building-inspection/
- telephone: 303-651-8332
Roofing permit required
Required
Contractor registration required
Required
Registration details
- license: A City of Longmont contractor's license is required; roof covering and waterproofing work falls under a Class D-2 specialty contractor's license.
Permit process note
A permit is required to reroof a house; repairs replacing less than 100 square feet of the total roof area do not require a permit.
Adopted code
The City of Longmont has adopted the International Residential Code for One- and Two-Family Dwellings, 2024 Edition, including Appendices BB, BE, BF, BG, BO, CA, CB and CF, and the International Building Code, 2024 edition, including Appendix I, both by reference at Longmont Municipal Code Chapter 16.06 (Secs. 16.06.010 and 16.06.030), with local amendments. The current chapter is new law rather than a revision: Ordinance No. O-2026-24, Section 1, adopted June 9, 2026, REPEALED the former Chapter 16.06 (Secs. 16.06.010 through 16.06.580) in its entirety and enacted a new Chapter 16.06 in its place. The repealed chapter derived from Ord. No. O-2021-65 (November 30, 2021) and Ord. No. O-2022-08 (March 29, 2022), which is why a 2021-edition answer was correct until June 2026 and is not correct now. Sec. 16.06.010 closes: "All references in this Code to the International Residential Code are to the edition referenced above."
Ice & water shield
Required — THE CITY'S OWN CODE AND THE CITY'S OWN ROOFING GUIDANCE POINT OPPOSITE WAYS ON THIS, AND A ROOFER NEEDS BOTH. Longmont's roofing guidelines page states: "The City of Longmont does require Ice & Water Shield. Manufacturer's installation instructions and code must be followed; where in conflict the more restrictive applies. Roof slopes between 1/12 and 2/12, above non-habitable space, are permitted to use a bituminous membrane (ice and water guard) then asphalt shingles." That page was read again on 2026-09-10 and still says so. But Longmont Municipal Code Sec. 16.06.160, enacted by Ord. No. O-2026-24 on June 9, 2026, amends Table R301.2 of the International Residential Code and its ICE SHIELD column reads "No" - the row also giving 30 psf ground snow, 110 mph nominal / 142 mph ultimate wind, seismic category B, severe weathering, a 30-inch frost line and a -2 degrees F winter design temperature. So the codified table does not trigger the model code's ice-barrier provision, while the Division that inspects the work says in writing that it requires the membrane. This record publishes true because the City's operational guidance is what an inspector applies and because the City's own conflict rule points to the more restrictive requirement, but it does not decide which of the two governs. Confirm with Building Inspection before pricing a roof without it.
About ice & water barrier
Mid-roof inspection
Required — Flat roofs only: "Ladders and mid-roof inspections are not required unless flat roof" (residential guidance) — no mid-roof for pitched asphalt-shingle re-roofs.
Impact-resistant roofing
Not required — Longmont does not require impact-resistant (UL 2218 Class 4) roofing. Ordinance No. O-2026-24, which repealed and reenacted Longmont Municipal Code chapter 16.06 to adopt the 2024 International Residential Code effective July 1, 2026, was reviewed in full, including its complete list of local amendments; the only roof-covering amendments are to IRC R908.1 (a roof with cumulative damage of 100 square feet or more must be replaced in its entirety) and R908.4 (roof recover), and no provision addresses impact resistance. The city's wind amendment sets a basic wind speed of 110 mph nominal / 142 mph ultimate, and its separately adopted Colorado Wildfire Resiliency Code (chapter 16.54) is a Class A fire-rating requirement; neither is an impact-resistance requirement.
Repair permit threshold
Repair of less than 10x10 (100 sq. ft.) is okay and no permit needed. The City of Longmont has a "1 square" rule (as of 2012): if more than 100 square feet of roofing requires repair or replacement, then the entire roof must be replaced, not just the affected roof area or plane (Longmont Municipal Code Amendment 16.06.300, IRC Section R908.1).
Wind design criteria
Longmont states the figure in both bases on the face of its own ordinance, so there is nothing to reconcile. Longmont Municipal Code Section 16.06.150, "Section R301.2.1.1 amended; wind limitation and wind design required", replaces that section of the International Residential Code in full with: "The basic wind speed for determining design wind pressure shall be 110 mph nominal or 142 mph ultimate." The City amended Table R301.2 to match at Section 16.06.160, where the WIND SPEED cell reads "110 mph nominal 142 mph ultimate". Both provisions were enacted by Ordinance No. O-2026-24, Section 1, adopted June 9, 2026, the ordinance that repealed and reenacted Chapter 16.06 and adopted the 2024 International Residential Code. The 110 and the 142 are the same loading expressed two ways -- do not apply the ultimate figure to a method that expects the nominal one, or the other way about. The codified table carries no exposure category, no topographic-effects entry, no special-wind-region entry and no windborne-debris entry; the same table gives a ground snow load of 30 psf and seismic design category B. Separately, the Building Inspection Division re-roofing guide imposes a product requirement rather than a design one: "ALL SHINGLES USED IN THE CITY OF LONGMONT MUST HAVE A MANUFACTURER'S WIND WARRANTY OF 110 MPH SUSTAINED WIND." That 110 is a sustained-wind warranty rating on the shingle and is not the code basic wind speed, even though the number matches.
Roof layer limit / recover
"How many layers of roofing are allowed? Roofs are allowed to have only 1 layer of shingles." (Single Family Residential Re-roofs guide; commercial roofs are handled separately and allow up to two layers on low-slope built-up roofing.)
Deck & sheathing requirements
"Roof Sheathing Preparation (for complete tear offs): The roof sheathing must provide a rigid surface. Repair or replace all boards or sheathing which are warped, cracked or delaminated between supports."
Sales & use tax
8.865% combined (state 2.9% + Boulder County 1.335% + RTD/CD 1.1% + Longmont city 3.53%; parts of Longmont in Weld County have a different county component). Home-rule self-collected. Longmont collects use tax on construction materials at building permit issuance, at a combined city+county rate of 4.715% (3.53% city + 1.335% Boulder County use tax) applied to an estimated 50% of project valuation; contractors who always pull permits and pay use tax this way need not hold a separate city sales tax license.
Local roofing hub
Roof permits nearby: Boulder County
Related guides
The building permitting authority for the City of Longmont, spanning Boulder and Weld counties. The Building Inspection Division issues reroofing permits, enforces the adopted building codes, and licenses building contractors.
Hail reports near Longmont, CO
- Reports, last 24 months
- 21
- Largest, last 24 months
- 1.75 in Jun 24, 2026
- Most recent
- Jul 28, 2026 1.00 in
- Reports, last 5 years
- 60
Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Longmont, CO (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.
Working an insurance claim in Longmont, CO? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).
Code items like drip edge and ice & water shield are what adjusters ask you to document.
Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.
Questions about the Longmont, CO pack?
Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.