Permitting Authorities / Wyoming / City of Laramie - Building Department (Code Administration)

Do you need a permit to replace a roof in Laramie, WY?

Adopted code

City of Laramie - Building Department (Code Administration)

Yes, a permit is required to replace a roof in Laramie, WY, issued by City of Laramie - Building Department (Code Administration). Laramie Municipal Code Section 15.24.000.D requires a permit before any work begins on a permitted project, and Section 15.24.000.E requires the contractor performing that work to hold the license required under Chapter 15.24 (see contractor_registration_required). The City's Building Permits and Informational Bulletins page lists the residential permit exceptions in full -- detached accessory sheds under 200 square feet, fences 7 feet or under, retaining walls 4 feet or under, small unattached decks, and painting or papering -- and roofing is not among them. All permit applications, including for roofing, are submitted through the City of Laramie's Civic Access web portal; estimated plan review is three weeks from submittal. Building permit fees are set by the valuation-based schedule in Informational Bulletin #25 (effective January 1, 2006), which carries no minimum-valuation exemption for residential repair work.

Roof code checklist: Laramie, WY

ItemAnswerCode citeSourceVerified
Permit to replace a roofYescityoflaramie.org2026-09-18
Repair permit thresholdNot published
Layer limit / roof-overPublishedcodes.iccsafe.org2026-09-18
Deck & sheathingPublishedcityoflaramie.org2026-09-18
Drip edgeYesR905.2.8.5cityoflaramie.org2026-09-18
Ice & water shieldYesR905.1.2cityoflaramie.org2026-09-18
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNolibrary.municode.com2026-09-18
Wind design criteriaPublishedlibrary.municode.com2026-09-18
Adopted codePublishedSec. 15.24.010cityoflaramie.org2026-09-18
Contractor license / registrationYeslibrary.municode.com2026-09-18
Sales & use taxPublishedexcise-tax-div.wyo.gov2026-09-18

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
City of Laramie, Wyoming
Jurisdiction type
city
Address
Laramie, WY
Contact
  • url: https://www.cityoflaramie.org/211/Building-Department-Code-Administration
  • telephone: 307-721-5271
Permit portal
Roofing permit required
Required
Contractor registration required
Required
Registration details
  • license: Laramie Municipal Code Section 15.24.015 requires a City-issued General Contractor license and a City-issued Qualified Supervisor of Record (QSOR) license to obtain a building permit or perform construction in the city. Four contractor classes exist; Class C (GC-C) is defined to cover "roof assemblies (new, repair, removal and replacement, re-shingle of existing)," siding, egress windows, and permitted fencing and signs. A GC-C applicant must employ a QSOR licensed at the Class C level, who must show at least three years of roofing, siding, window or fencing experience. Class C requires general liability insurance of $300,000 per occurrence / $600,000 aggregate. Fees are $300 new / $75 renewal for the GC-C license and $100 new / $50 renewal for the QSOR-C license; both expire December 31 each year. Working without the required license carries escalating fines of $250, $500 and $750 for repeat violations within a rolling twelve months.
Permit process note
Laramie Municipal Code Section 15.24.000.D requires a permit before any work begins on a permitted project, and Section 15.24.000.E requires the contractor performing that work to hold the license required under Chapter 15.24 (see contractor_registration_required). The City's Building Permits and Informational Bulletins page lists the residential permit exceptions in full -- detached accessory sheds under 200 square feet, fences 7 feet or under, retaining walls 4 feet or under, small unattached decks, and painting or papering -- and roofing is not among them. All permit applications, including for roofing, are submitted through the City of Laramie's Civic Access web portal; estimated plan review is three weeks from submittal. Building permit fees are set by the valuation-based schedule in Informational Bulletin #25 (effective January 1, 2006), which carries no minimum-valuation exemption for residential repair work.
Adopted code
Laramie Municipal Code Section 15.24.010 adopts the International Residential, Building, Existing Building, Mechanical, Plumbing, Fuel Gas and Energy Conservation Codes by a floating clause covering "the most recently issued editions ... as published by the International Code Council," together with the most recently issued National Electrical Code, codified through Ordinance No. 1881 (May 19, 2026). The City's own Informational Bulletin #30 (Roof Assemblies), dated May 2026, states that roof assemblies comply with the "International Residential Code (2024)" and the "International Building Code (2024)," and the City's "ICC 2024 Building Codes" page links the same 2024-cycle texts (IRC, IBC, IPC, IEBC, IFGC, IPMC, IFC, IECC) plus the 2023 NEC as the codes it references. That page's own wording ("all 2024 Codes that will be adopted by the City") is disclosed here because it reads as future tense; the City's dated bulletin and its own currently codified, floating-adoption ordinance text resolve it in favor of the 2024 suite being the code the City currently enforces.
Drip edge
Required — The City's Informational Bulletin #30 (Roof Assemblies, May 2026) states plainly that "Drip edge is required on the eave and the rake" and quotes IRC Section R905.2.8.5 in full. The City's enacted IRC amendment list (Section 15.24.010.A) does not amend Section R905.2.8.5, so the base 2024 IRC drip-edge requirement is in force as written and confirmed by the City's own bulletin. About drip edge
Ice & water shield
Required — Laramie Municipal Code Section 15.24.010.A.3 amends IRC Table R301.2 to state "Ice shield underlayment required = Yes" for the City of Laramie, alongside "Weathering = Severe" and a winter design temperature of -10 degrees F. The City's Informational Bulletin #30 confirms: "Ice barrier is required," citing IRC Section R905.1.2. About ice & water barrier
Impact-resistant roofing
Not required — Chapter 15.24 of the Laramie Municipal Code (Buildings and Construction), which contains the City's complete, currently codified list of amendments to the adopted International Residential and International Building Codes, was read in full: no provision amends IRC Section R905.2.4 or imposes a Class 4, UL 2218 or other impact-resistant roof-covering requirement. The City's own Informational Bulletins on roof assemblies and on adopted codes and design criteria likewise contain no impact-resistance, hail-rating or Class 4 language.
Wind design criteria
Laramie Municipal Code Section 15.24.010.A.3 amends IRC Table R301.2 to set "Wind speed = 115 mph (3-second gust)," "Topographic effects = Exposure C," "Special wind region = No" and "Wind-borne debris zone = No," alongside a ground and roof snow load of 30 psf. Section 15.24.010.B.10-11 separately amends IBC Sections 1608.1 and 1608.2 to set the same 30 psf minimum roof and ground snow load for commercial construction.
Roof layer limit / recover
Laramie Municipal Code Section 15.24.010.A adopts the International Residential Code by a floating clause ("the most recently issued editions ... adopted as published"), and the City's own numbered list of IRC amendments (items 1 through 8) touches only Section R101.1, the administration sections generally, Table R301.2, Sections R309.1, R309.2, R310.3, R325.5 and R608.8.2 -- none of it reaches Chapter 9. The 2024 IRC's R908.4 Roof recover Exceptions therefore governs unmodified: a new roof covering over an existing one is barred where "the existing roof has two or more applications of any type of roof covering," so one existing layer of asphalt shingles may be recovered but a second existing layer forces a tear-off. The City's own Informational Bulletin #30 (Roof Assemblies, dated May 2026) states the same governing edition ("International Residential Code (2024) Chapter 9 Roof Assemblies"), quotes this same Exceptions condition verbatim, and separately states "Maximum layers of asphalt shingles: one" -- confirming rather than contradicting the base-code reading.
Deck & sheathing requirements
The City's enacted IRC amendment list (Laramie Municipal Code Section 15.24.010.A) does not amend any provision of IRC Chapter 8, Roof-Ceiling Construction, so the base 2024 IRC roof-sheathing requirements apply unmodified in Laramie. The City's own Informational Bulletin #30 (Roof Assemblies, May 2026) states that asphalt shingles are fastened to wood structural panels or solid lumber sheathing and specifies minimum fastener penetration into the sheathing, consistent with that unmodified base code.
Sales & use tax
5% total sales/use tax in Albany County (4% state + 1% general purpose county option), per the Wyoming Department of Revenue Excise Tax Division's rate chart effective 07/01/2026. That rate is set to rise to 6% (adding a 1% specific purpose county option) effective 10/01/2026, per the Department's own next-effective chart, which shades the Albany County row as a rate change from the prior chart. Wyoming has no municipal sales-tax add-on, so the Albany County rate applies uniformly within Laramie.

The building permitting authority for the City of Laramie, Wyoming (Albany County). The Code Administration Division of the Community and Economic Development Department issues building, plumbing, mechanical, electrical and fire permits and provides plan review and inspection inside the city limits; permit applications and contractor license applications are submitted through the city's Civic Access web portal.

Hail reports near Laramie, WY

Reports, last 24 months
2
Largest, last 24 months
2.00 in Jun 17, 2025
Most recent
Jun 17, 2025 2.00 in
Reports, last 5 years
9
5 most recent reports, last 5 years
DateHail sizeDistance
Jun 17, 20252.00 in8 mi E
Jun 17, 20251.00 in4 mi ESE
Aug 8, 20241.00 in6 mi W
Jun 29, 20231.75 in1 mi NNE
Jun 29, 20231.25 in2 mi NE

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Laramie, WY (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.

Working an insurance claim in Laramie, WY? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Laramie, WY pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

The cheat sheet is free; the box above is optional. How we use your address: Privacy Policy.

Sources

Roofing questions: Laramie, WY

Do you need a permit to replace a roof in Laramie, WY?

Yes, a permit is required to replace a roof in Laramie, WY.

Is ice & water shield required in Laramie, WY?

Yes. Laramie Municipal Code Section 15.24.010.A.3 amends IRC Table R301.2 to state "Ice shield underlayment required = Yes" for the City of Laramie, alongside "Weathering = Severe" and a winter design temperature of -10 degrees F. The City's Informational Bulletin #30 confirms: "Ice barrier is required," citing IRC Section R905.1.2.

Is drip edge required in Laramie, WY?

Yes. The City's Informational Bulletin #30 (Roof Assemblies, May 2026) states plainly that "Drip edge is required on the eave and the rake" and quotes IRC Section R905.2.8.5 in full. The City's enacted IRC amendment list (Section 15.24.010.A) does not amend Section R905.2.8.5, so the base 2024 IRC drip-edge requirement is in force as written and confirmed by the City's own bulletin.

Can you roof over an existing roof in Laramie, WY?

Laramie Municipal Code Section 15.24.010.A adopts the International Residential Code by a floating clause ("the most recently issued editions ... adopted as published"), and the City's own numbered list of IRC amendments (items 1 through 8) touches only Section R101.1, the administration sections generally, Table R301.2, Sections R309.1, R309.2, R310.3, R325.5 and R608.8.2 -- none of it reaches Chapter 9. The 2024 IRC's R908.4 Roof recover Exceptions therefore governs unmodified: a new roof covering over an existing one is barred where "the existing roof has two or more applications of any type of roof covering," so one existing layer of asphalt shingles may be recovered but a second existing layer forces a tear-off. The City's own Informational Bulletin #30 (Roof Assemblies, dated May 2026) states the same governing edition ("International Residential Code (2024) Chapter 9 Roof Assemblies"), quotes this same Exceptions condition verbatim, and separately states "Maximum layers of asphalt shingles: one" -- confirming rather than contradicting the base-code reading.

Do roofing contractors need a license or registration in Laramie, WY?

Yes. Laramie Municipal Code Section 15.24.015 requires a City-issued General Contractor license and a City-issued Qualified Supervisor of Record (QSOR) license to obtain a building permit or perform construction in the city. Four contractor classes exist; Class C (GC-C) is defined to cover "roof assemblies (new, repair, removal and replacement, re-shingle of existing)," siding, egress windows, and permitted fencing and signs. A GC-C applicant must employ a QSOR licensed at the Class C level, who must show at least three years of roofing, siding, window or fencing experience. Class C requires general liability insurance of $300,000 per occurrence / $600,000 aggregate. Fees are $300 new / $75 renewal for the GC-C license and $100 new / $50 renewal for the QSOR-C license; both expire December 31 each year. Working without the required license carries escalating fines of $250, $500 and $750 for repeat violations within a rolling twelve months.

What building code does Laramie, WY use?

Laramie Municipal Code Section 15.24.010 adopts the International Residential, Building, Existing Building, Mechanical, Plumbing, Fuel Gas and Energy Conservation Codes by a floating clause covering "the most recently issued editions ... as published by the International Code Council," together with the most recently issued National Electrical Code, codified through Ordinance No. 1881 (May 19, 2026). The City's own Informational Bulletin #30 (Roof Assemblies), dated May 2026, states that roof assemblies comply with the "International Residential Code (2024)" and the "International Building Code (2024)," and the City's "ICC 2024 Building Codes" page links the same 2024-cycle texts (IRC, IBC, IPC, IEBC, IFGC, IPMC, IFC, IECC) plus the 2023 NEC as the codes it references. That page's own wording ("all 2024 Codes that will be adopted by the City") is disclosed here because it reads as future tense; the City's dated bulletin and its own currently codified, floating-adoption ordinance text resolve it in favor of the 2024 suite being the code the City currently enforces.