Permitting Authorities / Town of Yampa - Building Department

Do you need a permit to replace a roof in Yampa, CO?

Adopted code

Town of Yampa - Building Department

Yes — a permit is required to replace a roof in Yampa, CO, issued by Town of Yampa - Building Department. Title 15 of the Municipal Code states the Town has adopted codes "for the purpose of providing minimum standards to safeguard life or limb, health, property, and public welfare by regulating use and occupancy, location and maintenance of buildings ... regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, equipment, use, height, area and maintenance of all buildings or structures, and building service equipment; providing for the issuance of permits and collection of fees therefore." No roofing-specific permit language appears within Title 15 (the word "roof" appears in the 38-page posted PDF only as a structural-load or drainage term, never for a roof covering), so this note reflects the general building-permit requirement rather than a roofing-specific rule.

Jurisdiction
Town of Yampa, Colorado
Jurisdiction type
city
Address
101 Main Street, Yampa, CO 80483
Contact
Roofing permit required
Required
Permit process note
Title 15 of the Municipal Code states the Town has adopted codes "for the purpose of providing minimum standards to safeguard life or limb, health, property, and public welfare by regulating use and occupancy, location and maintenance of buildings ... regulating the erection, construction, enlargement, alteration, repair, moving, removal, demolition, conversion, occupancy, equipment, use, height, area and maintenance of all buildings or structures, and building service equipment; providing for the issuance of permits and collection of fees therefore." No roofing-specific permit language appears within Title 15 (the word "roof" appears in the 38-page posted PDF only as a structural-load or drainage term, never for a roof covering), so this note reflects the general building-permit requirement rather than a roofing-specific rule.
Adopted code
"There is hereby adopted by the Town of Yampa, Colorado ... to conform to the International Uniform Building Code (2003 Edition including Appendix Chapter C and J); International Residential Code (2003 Edition including Appendix Chapter E); International Existing Building Code (2003 Edition); Uniform Code for the Abatement of Dangerous Buildings (1997 Editions); National Electrical Code, Administrative Provisions (2003 Edition); International Uniform Mechanical Code (2003 Edition); International Plumbing Code (2003 Edition including Appendix Chapters B, D, E, F, G); International Fuel Gas Code (2003 Edition)." Section 15.01.03 states these codes were "amended and restated" from an earlier Ordinance No. 01-02; the posted Title 15 text itself does not show a later re-adoption to a newer ICC edition, so the 2003-edition codes are recorded as stated in the Town's own posted document.
Drip edge
Not required — The 2003 International Residential Code's Chapter 9, Roof Assemblies, contains no drip-edge requirement. Its flashing provisions for asphalt shingles (Section R905.2.8) cover base and cap flashing, valleys, crickets and saddles, sidewall flashing, and other penetration flashing only -- there is no drip-edge subsection, which first appears in a later IRC edition. No Town of Yampa amendment adds one. About drip edge
Ice & water shield
Required — The Town of Yampa's own completion of IRC Table R301.2(1), Climatic and Geographic Design Criteria, in Title 15 of its Municipal Code, states "Ice Shield Underlayment Required -- Yes." The same table also sets a 90 mph design wind speed and Seismic Design Category B. About ice & water barrier
Impact-resistant roofing
Not required — The Town of Yampa's Municipal Code, Title 15, Buildings and Construction, was read in full in its 38 pages. Chapter 15.01 adopts the Town's building codes by reference as restated from Ordinance 01-02, and Chapters 15.02 through 15.04 adopt the 2003 editions of the International Building Code, International Residential Code and International Existing Building Code, each amended section by section; no later edition is adopted anywhere in the title, so the adoption stands at the 2003 editions as amended. Every amendment was read. They address enforcement authority, permit fees and exemptions, fire-resistance of interior assemblies, sprinkler exceptions, stair and handrail dimensions, sound transmission, seismic design, frost protection and, at Sections R501.2, R601.2 and R801.2, a prohibition on using design tables based on roof live loads below 50 pounds per square foot or ground snow loads of 70 pounds per square foot or less, which is a structural loading rule. The Residential Code amendments proceed from Section R801.2 directly to Section N1101.1 and never reach Chapter 9, Roof Assemblies; the Building Code amendments never reach Chapter 15. Neither the adopted codes nor any Town amendment requires impact-resistant roof coverings or names a UL 2218 or Class 4 standard. The only statewide instrument reaching reroofing is the Colorado Wildfire Resiliency Code, 8 CCR 1507-39, effective July 1, 2026 in areas designated wildland-urban interface under that code, which requires a Class A roof covering tested to ASTM E108 or UL 790 where 25 percent or more of the roof surface is replaced, at Sections 101.6 and 403.2; that is a fire classification independent of impact rating, and the code sets no impact-resistance requirement.
Wind design criteria
The Town of Yampa's own completion of IRC Table R301.2(1) sets design wind speed at 90 MPH, Seismic Design Category B, ground snow load described as "Varies by site location and elevations (use actual roof snow load)" rather than a fixed number, weathering severe, frost line depth 48 inches, and winter design temperature 15 degrees F.
Roof layer limit / recover
The 2003 International Residential Code, Section R907.3, Recovering versus replacement, requires removal of the existing roof covering before a new one is installed if the existing roof has two or more applications of any type of roof covering (among other conditions -- water-soaked or deteriorated coverings, or existing wood shake, slate, clay, cement or asbestos-cement tile). Exceptions allow complete separate roofing systems (e.g. standing-seam metal) that do not rely on the existing roof for support, and metal panel, metal shingle, concrete or clay tile installed over an existing wood shake roof under Section R907.4. No Town of Yampa amendment touches Chapter 9.
Deck & sheathing requirements
The 2003 International Residential Code, Section R803, Roof Sheathing, sets two paths. Lumber sheathing (R803.1) must meet Table R803.1: minimum 5/8 inch net thickness at 24-inch rafter/beam spacing, 1-1/2 inch tongue-and-groove at wider spacings (48/60/72 inches, each with its own minimum bending-stress and stiffness value); spaced lumber sheathing is permitted only for wood shingle or shake roofing per Sections R905.7-R905.8 and is not allowed in Seismic Design Category D2. Wood structural panel sheathing (R803.2) must be identified or grade-marked to DOC PS1, PS2 or CSA O437 (R803.2.1), be of exterior exposure durability or Exposure 1 glue-bonded if used with interior- type panels on the underside (R803.2.1.1), meet the allowable spans of Table R503.2.1.1(1) (R803.2.2), and be installed with joints staggered or nonstaggered per Table R602.3(1) or APA E30 for wood roof framing (R803.2.3). No Town of Yampa amendment touches Chapter 8.
Sales & use tax
Town of Yampa combined sales tax rate is 7.9% (state 2.9% + Routt County 1% + Town of Yampa 4%). Both Routt County and the Town of Yampa are state-collected (neither carries a home-rule self-collecting asterisk on DR 1002), and Routt County is outside the RTD/SCFD special-district service area, so no district add-on applies.

The building permit authority for the Town of Yampa, a statutory town in Routt County. The Town administers its own building codes and permits under Title 15 (Buildings and Construction) of its Municipal Code, posted as a PDF from the Town's Municipal Code page. The Town Planner handles permit and zoning inquiries.

Working an insurance claim in Yampa, CO? Everything on this page — drip edge, ice & water shield, inspections, Class 4 rules — formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF) — one page, free.

Buy this jurisdiction's pack — $12 Delivered by email within minutes.

Questions about the Yampa, CO pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Free instant roof estimate — Yampa, CO

Ballpark your replacement in 20 seconds. No phone call required to see the number.

Roofing questions — Yampa, CO

Do you need a permit to replace a roof in Yampa, CO?

Required.

Is ice & water shield required in Yampa, CO?

Required — The Town of Yampa's own completion of IRC Table R301.2(1), Climatic and Geographic Design Criteria, in Title 15 of its Municipal Code, states "Ice Shield Underlayment Required -- Yes." The same table also sets a 90 mph design wind speed and Seismic Design Category B..

Is drip edge required?

Not required — The 2003 International Residential Code's Chapter 9, Roof Assemblies, contains no drip-edge requirement. Its flashing provisions for asphalt shingles (Section R905.2.8) cover base and cap flashing, valleys, crickets and saddles, sidewall flashing, and other penetration flashing only -- there is no drip-edge subsection, which first appears in a later IRC edition. No Town of Yampa amendment adds one..

What building code does Yampa, CO use?

"There is hereby adopted by the Town of Yampa, Colorado ... to conform to the International Uniform Building Code (2003 Edition including Appendix Chapter C and J); International Residential Code (2003 Edition including Appendix Chapter E); International Existing Building Code (2003 Edition); Uniform Code for the Abatement of Dangerous Buildings (1997 Editions); National Electrical Code, Administrative Provisions (2003 Edition); International Uniform Mechanical Code (2003 Edition); International Plumbing Code (2003 Edition including Appendix Chapters B, D, E, F, G); International Fuel Gas Code (2003 Edition)." Section 15.01.03 states these codes were "amended and restated" from an earlier Ordinance No. 01-02; the posted Title 15 text itself does not show a later re-adoption to a newer ICC edition, so the 2003-edition codes are recorded as stated in the Town's own posted document.