Permitting Authorities / Village of Schaumburg Community Development Department

Village of Schaumburg Community Development Department

Adopted code

The building permitting authority for the Village of Schaumburg, Illinois, which straddles Cook and DuPage counties. Illinois supplies no statewide residential building code reaching an existing house (the Capital Development Board says so in its own FAQ), so Schaumburg's roof-covering rules are entirely local. This record rests on the Village's own Municipal Code Chapter 153, Building Code, all 20 sections of which were read in full via Municode's public API this session.

Jurisdiction
Village of Schaumburg, Illinois
Jurisdiction type
city
Address
101 Schaumburg Court, Schaumburg, IL 60193
Contact
  • url: https://library.municode.com/il/schaumburg/codes/code_of_ordinances?nodeId=TIT15LAUS_CH153BUCO
Roofing permit required
Required
Contractor registration required
Required
Registration details
  • state_level: Illinois licenses roofing contractors statewide with no dollar threshold. 225 ILCS 335/9(2): "No work involving the construction, reconstruction, alteration, maintenance, or repair of any kind of roofing or waterproofing may be done except by a roofing contractor or a qualifying party licensed or credentialed under this Act." 225 ILCS 335/5(a-3): a municipality that requires a building permit may not issue one to a roofing contractor without proof of current state licensure, and 11(7) requires the permit-issuing official to verify it. The licence is held by the business entity, requires a continuous surety bond ($10,000 limited / $25,000 unlimited), liability and workers' compensation insurance, and a passed exam (225 ILCS 335/3(2)). The Act is scheduled to sunset January 1, 2031, a recurring legislative renewal date, not an expiry of current effect. The Village's own Business Regulations title (Chapters 110 through 129G, reviewed by table of contents this session) contains no separate roofing-contractor registration chapter of its own.
Adopted code
The Village adopts the 2021 International Codes (Building, Existing Building, Fire, Fuel Gas, Mechanical, named parts of the Plumbing Code, Property Maintenance, Residential, and Swimming Pool and Spa Codes) and the 2020 National Electrical Code by ordinance, per Schaumburg Municipal Code Section 153.02(a)-(b), all amendments to Chapter 153 effective December 1, 2022 (Ord. No. 18-032, passed 3-13-2018; Am. Ord. 22-084, passed 10-25-2022). Local amendments to the adopted ICC codes are cataloged in Section 153.03; none of the 20 sections comprising Chapter 153 (all read in full this session) amends the International Residential Code's Chapter 9, Roof Assemblies. Section 153.03(M) does fill in Table R301.2(1), Climatic and Geographic Design Criteria, for the 2021 IRC, and Section 153.03(Q) adds a local roof sheathing requirement at new Section R803.2.1.3.
Drip edge
Required — Not separately addressed by local amendment. Chapter 153 (all 20 sections read in full) amends roof sheathing and the climatic design table but does not amend the IRC's Chapter 9 roof-covering provisions, so the base 2021 IRC drip-edge requirement applies unmodified. About drip edge
Ice & water shield
Required — Section 153.03(M) fills in the 2021 IRC's Table R301.2(1), Climatic and Geographic Design Criteria, for Schaumburg and states outright: "Ice Barrier Underlayment Required?: Yes." About ice & water barrier
Impact-resistant roofing
Not required — Chapter 153 (all 20 sections read in full) contains no impact-resistance requirement for roof coverings: it has no occurrence of UL 2218, Class 4, Class IV, or hail. Its only "impact" provisions are vehicle impact protection devices (Section 153.12) and an impact insulation class rating for floor/ceiling sound transmission (Section 153.03(U)), neither of which concerns a roof covering.
Repair permit threshold
Section 153.03.4 exempts a repair or replacement from the permit requirement where either of two tests is met: the original material and labor value of the work is less than $500.00 (and it also complies with the size and location requirements of Chapter 154), or the area of repair or replacement is less than one hundred (100) square feet, an exemption the ordinance itself illustrates with the parenthetical "(i.e., siding or roofing)," provided in either case that the repairs are not life-safety related and involve no mechanical, electrical, plumbing, or fire-alarm work. An ordinary residential reroof, covering far more than 100 square feet, falls outside this exemption and needs a permit; Section 153.03.4.1(b) confirms this by listing "reroofs" among the single-family residential permit types valid for 180 days.
Wind design criteria
Section 153.03(M) fills in the 2021 IRC's Table R301.2(1), Climatic and Geographic Design Criteria, for Schaumburg: Ground Snow Load 25 pounds per square foot; Wind Speed 115 mph, 3-second gust (Topographic Effects: No; Special Wind Region: No; Wind-Borne Debris Zone: No); Seismic Design Category B; Weathering: Severe; Frost Line Depth 42 inches; Termite: Moderate to heavy; Winter Design Temperature -4 degrees Fahrenheit; Ice Barrier Underlayment Required: Yes; Air Freezing Index 2000; Mean Annual Temperature 50 degrees Fahrenheit.
Roof layer limit / recover
The Village's local amendments to the adopted 2021 IRC (Municipal Code Section 153.03, all 20 sections of Chapter 153 read in full) touch roof sheathing and the climatic design table but amend nothing in Chapter 9's reroofing provisions, so the unamended base 2021 IRC governs. 2021 IRC Section R908.3.1.1, Roof recover not allowed, bars a recover "where the existing roof has two or more applications of any type of roof covering," among other conditions, so a third or later layer over an existing two-layer roof is not permitted.
Deck & sheathing requirements
Section 153.03(Q) adds new Section R803.2.1.3 to the 2021 IRC: seven-sixteenths inch (7/16") or one-half inch (1/2") nominal wood structural panels are the minimum sheathing material for roof applications; on structures over 120 square feet, wood structural panels less than five-eighths inch (5/8") nominal, with rafter spacing greater than sixteen inches (16"), must have all sheathing edges blocked or galvanized metal ply clips installed, centered between roof truss systems, roof joists, or rafters, except where the sheathing is tongue and groove.
Sales & use tax
Illinois taxes the roofer, not the job, and the operative rate is not keyed to the Schaumburg job address. Under 86 Ill. Adm. Code 130.1940(c), a construction contractor "does not incur Retailers' Occupation Tax liability as to receipts from labor furnished and tangible personal property ... incorporated into a structure," but "incurs Use Tax on the cost price of the tangible personal property that is incorporated into real estate," with "roofing materials" named in the rule's own list of examples. Repair and replacement are taxed identically: 86 Ill. Adm. Code 130.1940(a)(3) defines "construct" to include "repair, renovate or remodel." The state rate has been 6.25% since January 1, 1990 (86 Ill. Adm. Code 130.101(c)(1)). The combined rate that actually lands on materials is the rate at the supply house's counter, or at the contractor's own place of business if self-assessed (86 Ill. Adm. Code 130.2075(b)(3)), which this record does not pin down. The authoritative lookup is the Illinois Department of Revenue's own MyTax Illinois Tax Rate Finder.

Working an insurance claim in Village of Schaumburg Community Development Department? Everything on this page — drip edge, ice & water shield, inspections, Class 4 rules — formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF) — one page, free.