Permitting Authorities / Township of White Oak - Building, Planning, & Zoning

Do you need a permit to replace a roof in Township of White Oak, MI?

Adopted code

Township of White Oak - Building, Planning, & Zoning

Yes, a permit is required to replace a roof in Township of White Oak, MI, issued by Township of White Oak - Building, Planning, & Zoning. In White Oak Township a reroof has its own entry on the Forms & Documents page, "Re-Roof Application", which opens the Township's Application for a Building Permit; the same form serves the remodel, deck and pole barn entries. The Building, Planning, & Zoning page says "The White Oak Township Zoning Administrator is the first point of contact for all new construction, address assignment, structural renovation or alteration, zoning issues and questions, or a land division in White Oak Township" and "The Zoning Administrator issues all permits except electrical." The form says "Once the Building Application and plans are approved, the Township Zoning Administrator will contact you with the total fee. Once the Township receives the fee, your building permit can be issued." It also says "All fees must be paid prior to issuance of zoning or building permit" and "All permits are valid for 12 months." Its requirements list asks for "A detailed description of work to be performed" and "The total value of the work to be performed", and says "Unless you own the home, a State of Michigan Residential Builders License is required for work on any residential structure." Send the application to the White Oak Township Building Department, 1002 S. M-52, Webberville, MI 48892; the Zoning & Building line is (517) 204-4458, the Township Hall line is (517) 851-8764, and the hall is open Tuesday and Thursday, 9:00 AM to 12:00 PM, or by appointment. For an inspection, call the building inspector at least 24 hours in advance.

Roof code checklist: Township of White Oak, MI

ItemAnswerCode citeSourceVerified
Permit to replace a roofYeswhiteoaktwpmi.gov2026-10-15
Repair permit thresholdPublishedwhiteoaktwpmi.gov2026-10-15
Layer limit / roof-overPublishedR908.3.1.1codes.iccsafe.org2026-10-15
Deck & sheathingPublishedR905.2.1codes.iccsafe.org2026-10-15
Drip edgeYesR905.2.8.5codes.iccsafe.org2026-10-15
Ice & water shieldYesR905.1.2ars.apps.lara.state.mi.us2026-10-15
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNoars.apps.lara.state.mi.us2026-10-15
Wind design criteriaNot published
Adopted codePublishedars.apps.lara.state.mi.us2026-10-15
Contractor license / registrationYeslegislature.mi.gov2026-10-15
Sales & use taxPublishedlegislature.mi.gov2026-10-15

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Township of White Oak, Ingham County, Michigan
Jurisdiction type
city
Address
1002 S. M-52, Webberville, MI 48892
Contact
  • url: https://whiteoaktwpmi.gov/building-planning-zoning/
  • phone: 517-204-4458
Roofing permit required
Required
Contractor registration required
Required
Permit process note
In White Oak Township a reroof has its own entry on the Forms & Documents page, "Re-Roof Application", which opens the Township's Application for a Building Permit; the same form serves the remodel, deck and pole barn entries. The Building, Planning, & Zoning page says "The White Oak Township Zoning Administrator is the first point of contact for all new construction, address assignment, structural renovation or alteration, zoning issues and questions, or a land division in White Oak Township" and "The Zoning Administrator issues all permits except electrical." The form says "Once the Building Application and plans are approved, the Township Zoning Administrator will contact you with the total fee. Once the Township receives the fee, your building permit can be issued." It also says "All fees must be paid prior to issuance of zoning or building permit" and "All permits are valid for 12 months." Its requirements list asks for "A detailed description of work to be performed" and "The total value of the work to be performed", and says "Unless you own the home, a State of Michigan Residential Builders License is required for work on any residential structure." Send the application to the White Oak Township Building Department, 1002 S. M-52, Webberville, MI 48892; the Zoning & Building line is (517) 204-4458, the Township Hall line is (517) 851-8764, and the hall is open Tuesday and Thursday, 9:00 AM to 12:00 PM, or by appointment. For an inspection, call the building inspector at least 24 hours in advance.
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Township of White Oak as its own building code enforcer. White Oak Township's Ordinance No. 10, Section 1 (Adopted: FEBRUARY 14, 1994) adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this directory has not read that text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. White Oak Township has published no statement naming the edition it enforces; its Ordinance No. 16 (adopted May 8, 2000) designates "the Building, Mechanical, and Plumbing Official of the Township of White Oak" as the enforcing agency "Pursuant to the provisions of the Michigan Building, Mechanical and Plumbing Codes", and its Ordinance No. 18 (adopted January 11, 2010) refers to "the current Michigan Mechanical, Plumbing, Building, Residential Electrical and Rehabilitation for Existing Buildings Code". The Township's Application for a Building Permit names no code edition.
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on drip edge. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code). About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on ice barrier. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code). About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on impact resistance.
Repair permit threshold
No size or cost threshold is published for roof work. The Township's Forms & Documents page lists a "Re-Roof Application" under "Building & Zoning", beside "Remodel Application", "Deck Application" and "Pole Barn Application", and the Building, Planning, & Zoning page says "The Zoning Administrator issues all permits except electrical." The Re-Roof Application link opens the same Application for a Building Permit that the remodel, deck and pole barn links open. Under state law, "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs. The Township sets no size or cost limit below which a reroof skips the permit.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." The Township's Ordinances No. 10, No. 16 and No. 18 and its building permit application were read and state no layer limit; the text of the BOCA code that Ordinance No. 10 adopts was not read, so this record sets no layer classification. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code).
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on roof sheathing. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code).
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." Nothing in the Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 changes this.

White Oak Township, in Ingham County, runs a Building, Planning, & Zoning department from the Township Hall at 1002 S. M-52 in Webberville, where the Zoning Administrator issues every permit except electrical. The Township's Forms & Documents page lists a Re-Roof Application beside its remodel, deck and pole barn applications. Michigan's single state construction code applies, and for houses that is the 2015 Michigan Residential Code.

Working an insurance claim in Township of White Oak, MI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Township of White Oak, MI pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Township of White Oak, MI

Do you need a permit to replace a roof in Township of White Oak, MI?

Yes, a permit is required to replace a roof in Township of White Oak, MI. No size or cost threshold is published for roof work. The Township's Forms & Documents page lists a "Re-Roof Application" under "Building & Zoning", beside "Remodel Application", "Deck Application" and "Pole Barn Application", and the Building, Planning, & Zoning page says "The Zoning Administrator issues all permits except electrical." The Re-Roof Application link opens the same Application for a Building Permit that the remodel, deck and pole barn links open. Under state law, "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs. The Township sets no size or cost limit below which a reroof skips the permit.

Is ice & water shield required in Township of White Oak, MI?

Yes. Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on ice barrier. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code).

Is drip edge required in Township of White Oak, MI?

Yes. Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). The Township's Building, Planning, & Zoning page, its Forms & Documents page, its Application for a Building Permit and its Ordinances No. 10, No. 16 and No. 18 were read for a local rule and state nothing further on drip edge. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code).

Can you roof over an existing roof in Township of White Oak, MI?

Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." The Township's Ordinances No. 10, No. 16 and No. 18 and its building permit application were read and state no layer limit; the text of the BOCA code that Ordinance No. 10 adopts was not read, so this record sets no layer classification. White Oak Township's Ordinance No. 10 adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state; White Oak Township has published no statement naming the edition it enforces; the BOCA National Building Code, Twelfth Edition, 1993 text was not read (see adopted_code).

Do roofing contractors need a license or registration in Township of White Oak, MI?

Yes.

What building code does Township of White Oak, MI use?

2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Township of White Oak as its own building code enforcer. White Oak Township's Ordinance No. 10, Section 1 (Adopted: FEBRUARY 14, 1994) adopts "The BOCA National Building Code, Twelfth Edition, 1993"; this directory has not read that text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. White Oak Township has published no statement naming the edition it enforces; its Ordinance No. 16 (adopted May 8, 2000) designates "the Building, Mechanical, and Plumbing Official of the Township of White Oak" as the enforcing agency "Pursuant to the provisions of the Michigan Building, Mechanical and Plumbing Codes", and its Ordinance No. 18 (adopted January 11, 2010) refers to "the current Michigan Mechanical, Plumbing, Building, Residential Electrical and Rehabilitation for Existing Buildings Code". The Township's Application for a Building Permit names no code edition.