Permitting Authorities / City of Pompano Beach - Building Department

Do you need a permit to replace a roof in Pompano Beach, FL?

Adopted code

City of Pompano Beach - Building Department

Yes, a permit is required to replace a roof in Pompano Beach, FL, issued by City of Pompano Beach - Building Department. The Building Department's Reroof permit checklist states: "The installation, replacement, or major repair of a roofing system requires a Building Permit. A permit is not required for minor repairs that do not affect approval or safety." The City's fee schedule has its own line, "Roofing Minimum: $75.00 (Roofing Permits)". Pompano Beach is in Broward County, part of the Florida Building Code's High-Velocity Hurricane Zone (HVHZ), where Florida Building Code, Building, Section 1512.3 states: "Permits within the HVHZ shall be required for all work in connection with the application, repair or maintenance of any roofing component or any roofing assembly and/or any of its components except as otherwise permitted in Section 105 of this code." The countywide Broward County amendments to the Florida Building Code (Section 105.3.1.4.10) require a permit for "The application, construction, or repair of any roof covering, as provided in Chapter 15, for work exceeding fifteen hundred dollars ($1,500.00)." The checklist calls for the Broward County Uniform Building Permit Application; the High Velocity Hurricane Zone Uniform Permit Application "with required attachments", which include the product approval pages and the Section 1524 owner's notification for roofing considerations (reroofing only), initialled by the owner and signed by the owner and the contractor; a Roofing Affidavit for Windstorm Loss Mitigation, "Required for single-family homes and duplexes"; a Rooftop Equipment Affidavit; "Miami-Dade NOA or Florida Product Approval for roofing materials, underlayments, fasteners, adhesives, and Fire Directory listing pages"; a Broward County Asbestos Certificate (Certificate of Submittal); and wind load verification. Where applicable, an HOA or condo approval letter is required, and a Notice of Commencement must be recorded with Broward County; "a recorded NOC is required prior to your first inspection." Applications are started in the City's Click2Gov portal or at the Building Department counter, and plans and documents are uploaded and reviewed electronically in ePlan; "Work may not begin until the permit has been issued.".

Roof code checklist: Pompano Beach, FL

ItemAnswerCode citeSourceVerified
Permit to replace a roofYespompanobeachfl.gov2026-09-26
Repair permit thresholdPublishedlibrary.municode.com2026-09-26
Layer limit / roof-overPublishedcodes.iccsafe.org2026-09-26
Deck & sheathingPublishedcodes.iccsafe.org2026-09-26
Drip edgeYescodes.iccsafe.org2026-09-26
Ice & water shieldNot published
Mid-roof inspectionYesSec. 1512.4.1pompanobeachfl.gov2026-09-26
Impact-resistant (Class 4) roofingNot published
Wind design criteriaPublishedcodes.iccsafe.org2026-09-26
Adopted codePublishedlibrary.municode.com2026-09-26
Contractor license / registrationYesleg.state.fl.us2026-09-26
Sales & use taxPublisheddr15dss_26.pdf2026-09-26

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
City of Pompano Beach, Florida
Jurisdiction type
city
Address
100 West Atlantic Boulevard, City Hall 3rd Floor, Pompano Beach, FL 33060
Contact
  • url: https://www.pompanobeachfl.gov/government/building-inspections/contact-information
  • phone: 954-786-4669
  • email: [email protected]
Permit portal
Roofing permit required
Required
Contractor registration required
Required
Registration details
  • state_level: Roofing is a separately licensed trade in Florida. Section 489.105(3)(e), Florida Statutes, defines a "Roofing contractor" as "a contractor whose services are unlimited in the roofing trade"; section 489.113(2) states that "A person must be certified or registered in order to engage in the business of contracting in this state." A state-certified contractor may work anywhere in Florida; under section 489.117(1)(b), "Registration allows the registrant to engage in contracting only in the counties, municipalities, or development districts where he or she has complied with all local licensing requirements, if any, and only for the type of work covered by the registration." Section 489.103(7) provides an owner-builder exemption for owners acting as their own contractor when building or improving a one-family or two-family residence "for the occupancy or use of such owners and not offered for sale or lease".
  • county_level: The countywide Broward County amendments to the Florida Building Code (Section 105.3.0.1.1) state that persons or firms applying for permits "shall be qualified in accordance with the rules of the Broward County Central Examining Board, Ordinance No. 78-9, and Chapter 9 of the Broward County Codes; the State of Florida, Department of Professional Regulation by authority of Florida Statute, Chapter 489, Parts One and Two; or other Examining Boards as specifically approved by BORA." The City accepts a Broward County Certificate of Competency for contractor registration.
  • city_level: The City's Contractor Registration page states: "To obtain a permit for any licensed construction or alteration work within the City of Pompano Beach, all contractors must submit their license and insurance information online." State-certified contractors provide the state licence and general liability and workers' compensation insurance certificates naming the City of Pompano Beach as certificate holder (or a workers' compensation exemption); holders of a Broward County Certificate of Competency provide that certificate and the same insurance. The Building Department's notice on contractor licensing changes states: "If the work is regulated under the Florida Building Code, a valid State of Florida contractor license is still required." Florida Building Code, Building, Section 1512.3.1 (High-Velocity Hurricane Zone) states that the HVHZ Uniform Roofing Permit Application is to be "completed and executed by a licensed contractor". The City publishes an Owner Builder Statement/Affidavit for owners applying under section 489.103(7), Florida Statutes, whose disclosure statement reads: "I understand that state law requires construction to be done by a licensed contractor and have applied for an owner-builder permit under an exemption from the law." A City Business Tax Receipt is required for businesses located in Pompano Beach; the City states this "is separate from contractor registration", and it is not a contractor credential.
Permit process note
The Building Department's Reroof permit checklist states: "The installation, replacement, or major repair of a roofing system requires a Building Permit. A permit is not required for minor repairs that do not affect approval or safety." The City's fee schedule has its own line, "Roofing Minimum: $75.00 (Roofing Permits)". Pompano Beach is in Broward County, part of the Florida Building Code's High-Velocity Hurricane Zone (HVHZ), where Florida Building Code, Building, Section 1512.3 states: "Permits within the HVHZ shall be required for all work in connection with the application, repair or maintenance of any roofing component or any roofing assembly and/or any of its components except as otherwise permitted in Section 105 of this code." The countywide Broward County amendments to the Florida Building Code (Section 105.3.1.4.10) require a permit for "The application, construction, or repair of any roof covering, as provided in Chapter 15, for work exceeding fifteen hundred dollars ($1,500.00)." The checklist calls for the Broward County Uniform Building Permit Application; the High Velocity Hurricane Zone Uniform Permit Application "with required attachments", which include the product approval pages and the Section 1524 owner's notification for roofing considerations (reroofing only), initialled by the owner and signed by the owner and the contractor; a Roofing Affidavit for Windstorm Loss Mitigation, "Required for single-family homes and duplexes"; a Rooftop Equipment Affidavit; "Miami-Dade NOA or Florida Product Approval for roofing materials, underlayments, fasteners, adhesives, and Fire Directory listing pages"; a Broward County Asbestos Certificate (Certificate of Submittal); and wind load verification. Where applicable, an HOA or condo approval letter is required, and a Notice of Commencement must be recorded with Broward County; "a recorded NOC is required prior to your first inspection." Applications are started in the City's Click2Gov portal or at the Building Department counter, and plans and documents are uploaded and reviewed electronically in ePlan; "Work may not begin until the permit has been issued."
Inspection requirements
The City's Reroof permit checklist lists the roofing inspections "BLDG TIN TAG", "BLDG MOP-IN PROGRESS", "BLDG TILE/SHINGLE-IN PROGRESS" and "BLDG FINAL STRUCTURAL", plus a Fire Department final where applicable. Inspections are scheduled online through the City's permitting portal and are conducted Monday through Thursday; requests submitted by midnight are scheduled for the next available business day. The countywide Broward County amendments to the Florida Building Code (Section 110.3) require inspections "by BORA certified inspectors within their specific disciplines", including a roof sheathing inspection and a roofing inspection "in accordance with Chapter 15 of the FBC, and Section 706 of the FBC, Existing Building"; work for which a permit is required "shall remain accessible and exposed for inspection purposes until approved" (Section 110.1). Under Florida Building Code, Building, Section 1512.4 (High-Velocity Hurricane Zone), shingle, tile and other discontinuous roofs are inspected during or after the base sheet, anchor sheet or underlayment, during installation of any cap sheet and of the roof covering, with a TAS 106 uplift test for adhesive-set and mortar-set tile before the final inspection. A recorded Notice of Commencement is required before the first inspection.
Adopted code
Florida Building Code, 8th Edition (2023), effective December 31, 2023 (Rule 61G20-1.001, F.A.C.), including its High-Velocity Hurricane Zone (HVHZ) provisions; the Residential volume defines the HVHZ as consisting "of Broward and Miami-Dade counties". The Building Department states that it is committed to "enforcing the standards of the Florida Building Code". The Broward County Board of Rules and Appeals publishes the Broward County Amendments to the Florida Building Code 8th Edition (2023), adopted December 14, 2023, with amendments effective through March 30, 2026, whose Chapter 1 (Administration) states that its provisions "shall apply countywide in both incorporated and unincorporated areas of Broward County, Florida." Because Pompano Beach is in the HVHZ, roofing on houses follows Florida Building Code, Building, Sections 1512 through 1525 rather than Chapter 9 of the Residential volume, whose Section R901.1 states: "Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44." The City's own Code of Ordinances is published by American Legal Publishing and could not be opened for this record, so any City building-code provisions in it are not reflected here.
Drip edge
Required — In the High-Velocity Hurricane Zone, which includes all of Broward County, Florida Building Code, Building, Section 1518.7.3.4 requires for asphalt shingle roofs that "All perimeter termination and valleys shall be fabricated from metal. Minimum metal requirements are set forth in Section 1517.6 and RAS 111." Section 1517.6.2.1 sets the gravel stop or drip edge profile: "The vertical face shall be a minimum of 1 1/2 inches (38 mm) and shall extend down not less than 1/2 inch (12.7 mm) below the sheathing or other member immediately contiguous thereto. In all cases, the deck flange shall be not less than 2 inches (51 mm) in width. Gravel stop or drip edge shall be sized, designed and installed in compliance with RAS 111." Section 1517.6.2.6 requires the deck flange to be "nailed with an approved minimum 12 gage annular ring shank nail at 4 inches (102 mm) o.c." The HVHZ Uniform Permit Application the City requires for reroofs asks, for steep-sloped roofs, for the "Type & Size Drip Edge". About drip edge
Mid-roof inspection
Required — The City's Reroof permit checklist lists these roofing inspections: "BLDG TIN TAG", "BLDG MOP-IN PROGRESS", "BLDG TILE/SHINGLE-IN PROGRESS" and "BLDG FINAL STRUCTURAL". Florida Building Code, Building, Section 1512.4.1 (High-Velocity Hurricane Zone) states that "Certain roofing inspections shall be performed during specific phases of the applications"; for shingle, tile and other discontinuous roofs these include "During or after application of the base sheet, anchor sheet or underlayment of any roofing system" (1512.4.2.1) and "During the installation of any prepared roof covering, such as shingles, tiles, slates, shakes and similar" (1512.4.2.3). The countywide Broward County amendments to the Florida Building Code (Section 110.3) also list a "Roof Sheathing" inspection, "To be made after placement of panels or planking and sheathing fasteners, prior to application of base or anchor coat of roofing."
Repair permit threshold
City Reroof checklist: "A permit is not required for minor repairs that do not affect approval or safety." Broward County's countywide amendments to the Florida Building Code (Section 105.2, Work exempt from permit): "Roofing. 1. No permit will be required for maintenance or repair of any roof covering, as provided in Chapter 15, for work not exceeding fifteen hundred dollars ($1,500.00) as determined by the Building Official." The same section exempts "general maintenance or repairs which do not change the occupancy and the value of which does not exceed fifteen hundred dollars ($1,500.00) in labor and material as determined by the Building Official", and Section 105.3.1.4.10 requires a permit for roof covering work "exceeding fifteen hundred dollars ($1,500.00)". State exemption since July 1, 2026, section 553.79(1)(g), Florida Statutes: "A local government that issues building permits shall exempt an owner of a single-family dwelling or the owner's contractor from the requirement to obtain a building permit to perform any work valued at less than $7,500 on the owner's property." It does not apply to "Work on a property that is partially or entirely located in a flood hazard area as defined by the Florida Building Code" or to "Any electrical, plumbing, structural, mechanical, or gas work performed on property containing a single-family dwelling"; "A construction project may not be divided into more than one project for the purpose of evading the requirements of this paragraph"; and the owner or contractor "must submit a written request for exemption to the local enforcement agency with a copy of the contract or other documentation demonstrating the nature and the value of the work to be performed." The City's Building Permit Exemption Request form (revised July 1, 2026) states that "Properties in Zones A, AE, AH, AO, AR, A99, V, and VE are not eligible", requires that "The property is a single-family residence only and is not a duplex, condominium, townhouse, multifamily, or commercial property" and that the Building work "is valued at less than $7,500, including applicable labor and materials, does not include structural work", and is submitted and processed like a permit application. The City's notice on the exemption describes structural work as "anything affecting load-bearing walls, roof framing, or foundations"; its list of qualifying work does not mention reroofing either way. Separately, the HVHZ 25 percent rule (Florida Building Code, Building, Section 1521.4): "Not more than 25 percent of the total roof area or roof section of any existing building or structure shall be repaired, replaced or recovered in any 12-month period unless the roof covering on the entire existing roof system or roof section is replaced or recovered to conform to the requirements of this code." Its exception: where the existing roof was built, repaired or replaced under the 2007 Florida Building Code or later, "only the repaired, replaced, or recovered portion is required to be constructed in accordance with the Florida Building Code in effect, as applicable."
Wind design criteria
Pompano Beach is in Broward County, part of the Florida Building Code's High-Velocity Hurricane Zone (HVHZ). Florida Building Code, Building, Section 1620.2 sets the wind velocity (3-second gust) used in structural calculations for Broward County at 156 mph for Risk Category I, 170 mph for Risk Category II, 180 mph for Risk Category III and 185 mph for Risk Category IV buildings and structures, and Section 1620.3 states: "All buildings and structures shall be considered to be in Exposure Category C, unless Exposure Category D applies, as defined in Section 26.7 of ASCE 7." The City's Reroof permit checklist requires wind load verification "demonstrating compliance with required design pressures for the proposed roofing system" and states that "One- and two-family dwellings or townhomes may use the Fenestration Wind Load and Roof Uplift Chart, while multi-family, commercial, or non-prescriptive projects must provide engineer-sealed wind pressure calculations." The HVHZ Uniform Roofing Permit Application must include calculations under Chapter 16 (High-Velocity Hurricane Zones) "unless the roofing assembly is less than the height/pressure threshold allowed in the applicable protocols herein" (Section 1512.3.2). Asphalt shingles in the HVHZ are limited to "a roof mean height of 33 feet (10 m), unless otherwise specifically noted in the product approval" (Section 1518.7.2).
Roof layer limit / recover
Pompano Beach is in the High-Velocity Hurricane Zone, where reroofing follows Florida Building Code, Building, Section 1521 rather than the Residential code's reroofing section; the Broward County amendments to the Florida Building Code (Chapter 1, Administration) do not amend Section 1521. Section 1521.9: "One additional roofing system may be applied over an original roofing assembly, providing the existing roofing assembly complies with the requirements of Section 1521." Section 1521.17: "Asphalt shingle assemblies may be applied over one existing layer of asphalt shingles having not more than 1/8-inch (3.2 mm) difference in level in the existing shingle material." Section 1521.16: "No recover application shall take place over existing wood shingles, shakes, slate, tile or metal shingles." Section 1521.19: "Roof coverings or roofing components, such as tile, slate or similar, shall not be applied over an existing roofing system." Section 1521.5 also bars a roofing system "over an existing roof or over an existing roof deck where the roof sheathing has not been fastened in compliance with this code or where the roof sheathing will not permit effective fastening or where sheathing is water soaked or deteriorated so that effective attachment is not possible." The City's own Code of Ordinances could not be opened for this record.
Deck & sheathing requirements
High-Velocity Hurricane Zone rules (Florida Building Code, Building): "All roofing systems and prepared roof coverings shall be installed over solid decks, unless otherwise specifically allowed in other sections of this code" (1515.2.1). On a reroof, no new roofing system may go over a deck "where the roof sheathing has not been fastened in compliance with this code"; "All areas of deteriorated sheathing shall be removed and replaced", and "The building official shall not be required to inspect the renailing of the sheathing under this section" (1521.5). Where an existing sloped roof has spaced sheathing, the existing prepared roof covering must be removed and "New sheathing shall be applied in compliance with Chapter 16 (High-Velocity Hurricane Zones), or open spacing shall be filled with dimensional lumber to create solid wood sheathing"; "Spaced sheathing is approved for use with wood shakes and wood shingles only" (1521.15). For houses with wood roof decks built before the Florida Building Code, Florida Building Code, Existing Building, Section 706.7 provides that when the roof covering is removed and replaced, "Roof-decking attachment shall be as required by Section 706.7.1" and "A secondary water barrier shall be provided as required by Section 706.7.2", with the exception that "Structures permitted subject to the Florida Building Code are not required to comply with this section." The HVHZ owner's notification the City requires with a reroof permit states: "When replacing roofing, the existing wood roof deck may have to be renailed in accordance with the current provisions of Chapter 16 (High-Velocity Hurricane Zones) of the Florida Building Code, Building." The Broward County amendments list a roof sheathing inspection "after placement of panels or planking and sheathing fasteners, prior to application of base or anchor coat of roofing."
Sales & use tax
7% combined: the 6% Florida state sales and use tax plus Broward County's 1% discretionary sales surtax, which Florida Department of Revenue Form DR-15DSS for Calendar Year 2026 lists as effective January 1, 2019 with an expiration date of December 31, 2048. DR-15DSS lists no separate Pompano Beach rate. For roofing, Rule 12A-1.051, F.A.C., lists "Roofing work" among real property contracts and states that "Contractors are the ultimate consumers of materials and supplies they use to perform real property contracts and must pay tax on their costs of those materials and supplies, unless the contractor has entered a retail sale plus installation contract", and that such contractors "should charge no tax to their customers". The rule's definition of a real property contract covers work to "Erect, construct, alter, repair, or maintain" a building, so repairs and full replacements are treated alike.

The City of Pompano Beach Building Department issues building permits, including reroof permits, for properties in the City of Pompano Beach and enforces the Florida Building Code. Applications are made on the Broward County Uniform Building Permit Application through the City's Click2Gov portal or in person at City Hall, and plans are reviewed electronically in the City's ePlan system.

Hail reports near Pompano Beach, FL

Reports, last 24 months
2
Largest, last 24 months
1.00 in Jul 12, 2025
Most recent
Jul 12, 2025 1.00 in
Reports, last 5 years
4
4 most recent reports, last 5 years
DateHail sizeDistance
Jul 12, 20251.00 in8 mi WSW
Jul 12, 20251.00 in7 mi W
Jul 17, 20231.00 in9 mi NW
Apr 17, 20230.75 in5 mi SW

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Pompano Beach, FL (Census point). Data through Sep 30, 2026. A report is an observation, not a damage record.

Working an insurance claim in Pompano Beach, FL? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes.

Questions about the Pompano Beach, FL pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Pompano Beach, FL

Do you need a permit to replace a roof in Pompano Beach, FL?

Yes, a permit is required to replace a roof in Pompano Beach, FL. City Reroof checklist: "A permit is not required for minor repairs that do not affect approval or safety." Broward County's countywide amendments to the Florida Building Code (Section 105.2, Work exempt from permit): "Roofing. 1. No permit will be required for maintenance or repair of any roof covering, as provided in Chapter 15, for work not exceeding fifteen hundred dollars ($1,500.00) as determined by the Building Official." The same section exempts "general maintenance or repairs which do not change the occupancy and the value of which does not exceed fifteen hundred dollars ($1,500.00) in labor and material as determined by the Building Official", and Section 105.3.1.4.10 requires a permit for roof covering work "exceeding fifteen hundred dollars ($1,500.00)". State exemption since July 1, 2026, section 553.79(1)(g), Florida Statutes: "A local government that issues building permits shall exempt an owner of a single-family dwelling or the owner's contractor from the requirement to obtain a building permit to perform any work valued at less than $7,500 on the owner's property." It does not apply to "Work on a property that is partially or entirely located in a flood hazard area as defined by the Florida Building Code" or to "Any electrical, plumbing, structural, mechanical, or gas work performed on property containing a single-family dwelling"; "A construction project may not be divided into more than one project for the purpose of evading the requirements of this paragraph"; and the owner or contractor "must submit a written request for exemption to the local enforcement agency with a copy of the contract or other documentation demonstrating the nature and the value of the work to be performed." The City's Building Permit Exemption Request form (revised July 1, 2026) states that "Properties in Zones A, AE, AH, AO, AR, A99, V, and VE are not eligible", requires that "The property is a single-family residence only and is not a duplex, condominium, townhouse, multifamily, or commercial property" and that the Building work "is valued at less than $7,500, including applicable labor and materials, does not include structural work", and is submitted and processed like a permit application. The City's notice on the exemption describes structural work as "anything affecting load-bearing walls, roof framing, or foundations"; its list of qualifying work does not mention reroofing either way. Separately, the HVHZ 25 percent rule (Florida Building Code, Building, Section 1521.4): "Not more than 25 percent of the total roof area or roof section of any existing building or structure shall be repaired, replaced or recovered in any 12-month period unless the roof covering on the entire existing roof system or roof section is replaced or recovered to conform to the requirements of this code." Its exception: where the existing roof was built, repaired or replaced under the 2007 Florida Building Code or later, "only the repaired, replaced, or recovered portion is required to be constructed in accordance with the Florida Building Code in effect, as applicable."

Is drip edge required in Pompano Beach, FL?

Yes. In the High-Velocity Hurricane Zone, which includes all of Broward County, Florida Building Code, Building, Section 1518.7.3.4 requires for asphalt shingle roofs that "All perimeter termination and valleys shall be fabricated from metal. Minimum metal requirements are set forth in Section 1517.6 and RAS 111." Section 1517.6.2.1 sets the gravel stop or drip edge profile: "The vertical face shall be a minimum of 1 1/2 inches (38 mm) and shall extend down not less than 1/2 inch (12.7 mm) below the sheathing or other member immediately contiguous thereto. In all cases, the deck flange shall be not less than 2 inches (51 mm) in width. Gravel stop or drip edge shall be sized, designed and installed in compliance with RAS 111." Section 1517.6.2.6 requires the deck flange to be "nailed with an approved minimum 12 gage annular ring shank nail at 4 inches (102 mm) o.c." The HVHZ Uniform Permit Application the City requires for reroofs asks, for steep-sloped roofs, for the "Type & Size Drip Edge".

Can you roof over an existing roof in Pompano Beach, FL?

Pompano Beach is in the High-Velocity Hurricane Zone, where reroofing follows Florida Building Code, Building, Section 1521 rather than the Residential code's reroofing section; the Broward County amendments to the Florida Building Code (Chapter 1, Administration) do not amend Section 1521. Section 1521.9: "One additional roofing system may be applied over an original roofing assembly, providing the existing roofing assembly complies with the requirements of Section 1521." Section 1521.17: "Asphalt shingle assemblies may be applied over one existing layer of asphalt shingles having not more than 1/8-inch (3.2 mm) difference in level in the existing shingle material." Section 1521.16: "No recover application shall take place over existing wood shingles, shakes, slate, tile or metal shingles." Section 1521.19: "Roof coverings or roofing components, such as tile, slate or similar, shall not be applied over an existing roofing system." Section 1521.5 also bars a roofing system "over an existing roof or over an existing roof deck where the roof sheathing has not been fastened in compliance with this code or where the roof sheathing will not permit effective fastening or where sheathing is water soaked or deteriorated so that effective attachment is not possible." The City's own Code of Ordinances could not be opened for this record.

Do roofing contractors need a license or registration in Pompano Beach, FL?

Yes.

What building code does Pompano Beach, FL use?

Florida Building Code, 8th Edition (2023), effective December 31, 2023 (Rule 61G20-1.001, F.A.C.), including its High-Velocity Hurricane Zone (HVHZ) provisions; the Residential volume defines the HVHZ as consisting "of Broward and Miami-Dade counties". The Building Department states that it is committed to "enforcing the standards of the Florida Building Code". The Broward County Board of Rules and Appeals publishes the Broward County Amendments to the Florida Building Code 8th Edition (2023), adopted December 14, 2023, with amendments effective through March 30, 2026, whose Chapter 1 (Administration) states that its provisions "shall apply countywide in both incorporated and unincorporated areas of Broward County, Florida." Because Pompano Beach is in the HVHZ, roofing on houses follows Florida Building Code, Building, Sections 1512 through 1525 rather than Chapter 9 of the Residential volume, whose Section R901.1 states: "Exception: Buildings and structures located within the High-Velocity Hurricane Zone shall comply with the provisions of Chapter 44." The City's own Code of Ordinances is published by American Legal Publishing and could not be opened for this record, so any City building-code provisions in it are not reflected here.

Is a mid-roof inspection required in Pompano Beach, FL?

Yes. The City's Reroof permit checklist lists these roofing inspections: "BLDG TIN TAG", "BLDG MOP-IN PROGRESS", "BLDG TILE/SHINGLE-IN PROGRESS" and "BLDG FINAL STRUCTURAL". Florida Building Code, Building, Section 1512.4.1 (High-Velocity Hurricane Zone) states that "Certain roofing inspections shall be performed during specific phases of the applications"; for shingle, tile and other discontinuous roofs these include "During or after application of the base sheet, anchor sheet or underlayment of any roofing system" (1512.4.2.1) and "During the installation of any prepared roof covering, such as shingles, tiles, slates, shakes and similar" (1512.4.2.3). The countywide Broward County amendments to the Florida Building Code (Section 110.3) also list a "Roof Sheathing" inspection, "To be made after placement of panels or planking and sheathing fasteners, prior to application of base or anchor coat of roofing."