Permitting Authorities / City of Norton Shores - Building Division
Do you need a permit to replace a roof in Norton Shores, MI?
Adopted code
City of Norton Shores - Building Division
Yes, a permit is required to replace a roof in Norton Shores, MI, issued by City of Norton Shores - Building Division. Plan on a building permit for a re-roof in Norton Shores. The Building Division's Roofing Handout lists the "Steps for shingling projects": "1. Get a Permit. 2. Follow the Manufacturer's Specifications. 3. Inspections: A. Provide Photos of Sheathing and Ice Barrier. B. Call for a Final Inspection." In place of the first inspection "the installer may provide photographs that show sheathing and properly-installed ice barrier (showing full perimeter)," e-mailed to the department with the address in the subject line; when the job is done, "call the Building Division at 799-6801 for the required final inspection of the work." The handout adds that roofing contractors "must be licensed with the State of Michigan & registered with the City of Norton Shores." Contractors "need to register when applying for a permit for the first time" with the registration form, a copy of the license and liability insurance, and "We do not charge for Contractor Registrations." The building permit fee schedule ("EFFECTIVE 9/3/2019") prices a permit by total valuation, with a "$50.00 Minimum" for $1.00 to $1,000. The Building Division is at 4814 Henry Street, Norton Shores; call 231-799-6801 or email [email protected].
Roof code checklist: Norton Shores, MI
Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.
Jurisdiction
City of Norton Shores, Michigan
Address
4814 Henry Street, Norton Shores, MI 49441
Roofing permit required
Required
Contractor registration required
Required
Registration details
- state_level: Michigan licenses residential maintenance and alteration contractors under the Occupational Code, and that licence "includes the following crafts and trades" among which it names roofing (MCL 339.2404(3)); "A person shall not engage in or attempt to engage in the practice of an occupation regulated under this act" without the licence (MCL 339.601(1)). MCL 339.2403 lists who may work without one, including a project whose "aggregate contract price for the labor, material, and any other items for the undertaking or project is less than $600.00". This record does not decide whether a given roofer falls inside an exemption.
- city_level: Norton Shores registers contractors but sets no roofing licence of its own. Its Roofing Handout says roofing contractors "must be licensed with the State of Michigan & registered with the City of Norton Shores," and the city says "Contractors need to register when applying for a permit for the first time" and "We do not charge for Contractor Registrations." City Code Chapter 8 (read in full) sets no roofing contractor licence.
Permit process note
Plan on a building permit for a re-roof in Norton Shores. The Building Division's Roofing Handout lists the "Steps for shingling projects": "1. Get a Permit. 2. Follow the Manufacturer's Specifications. 3. Inspections: A. Provide Photos of Sheathing and Ice Barrier. B. Call for a Final Inspection." In place of the first inspection "the installer may provide photographs that show sheathing and properly-installed ice barrier (showing full perimeter)," e-mailed to the department with the address in the subject line; when the job is done, "call the Building Division at 799-6801 for the required final inspection of the work." The handout adds that roofing contractors "must be licensed with the State of Michigan & registered with the City of Norton Shores." Contractors "need to register when applying for a permit for the first time" with the registration form, a copy of the license and liability insurance, and "We do not charge for Contractor Registrations." The building permit fee schedule ("EFFECTIVE 9/3/2019") prices a permit by total valuation, with a "$50.00 Minimum" for $1.00 to $1,000. The Building Division is at 4814 Henry Street, Norton Shores; call 231-799-6801 or email
[email protected].
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the City of Norton Shores as its own building code enforcer. City Code Chapter 8 says "the fire department shall act as the building official of the city" and designates it the enforcing agency under the state construction code act, without naming an edition; the city's Roofing Handout is headed "MICHIGAN RESIDENTIAL CODE 2015". Chapter 8 (Buildings and Building Regulations) was read in full; its only residential code text supplies flood hazard content for Table R301.2(1) of the Michigan Residential Code.
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Norton Shores's building ordinance, City Code Chapter 8 (read in full), states nothing further on drip edge.
About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Norton Shores's building ordinance, City Code Chapter 8 (read in full), states nothing further on ice barrier.
About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." Norton Shores's building ordinance, City Code Chapter 8 (read in full), adds no roof-covering rule; no UL 2218 or Class 4 impact requirement appears in it.
Repair permit threshold
Norton Shores treats re-roofing as permit work with no size or cost threshold. Its Building FAQs say "Permits are usually required for the following:" and list "Renovations (garage conversions, basement furnishings, kitchen expansions, re-roofing, etc.)", and among the jobs needing a permit name the work to "apply roofing materials". The Roofing Handout says "The Michigan State Building Code requires a Building Permit for roofing work. R105.1" Under state law "A building permit is not required for ordinary repairs of a building or structure", and the act does not define ordinary repairs; for a small patch, call the Building Division (231-799-6801) before starting.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." The city's Roofing Handout says "New roof coverings shall not be installed without first removing existing roof coverings for the 4 conditions," citing the code's reroofing section, and states no different layer count. Norton Shores's own building ordinance, City Code Chapter 8 (Buildings and Building Regulations), was read in full: it designates the enforcing agency and covers electrical work, flood damage prevention, swimming pools and rental property, and it touches nothing in the reroofing section, so the state limit applies unchanged.
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). Norton Shores's building ordinance, City Code Chapter 8 (read in full), states nothing further on roof sheathing.
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." The City of Norton Shores adds no sales tax of its own, so 6% is the whole rate on a job there.
Local roofing hub
More roof permit pages in Michigan
Related guides
The City of Norton Shores Building Division, at 4814 Henry Street, issues building permits in the city and inspects the work; its Roofing Handout tells permit holders to "Get a Permit" for shingling projects. Michigan applies one residential code statewide, so the roofing rules below are state law; the city enforces them and sets its own permit fees.
Working an insurance claim in Norton Shores, MI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).
Code items like drip edge and ice & water shield are what adjusters ask you to document.
Buy this jurisdiction's pack: $12 Delivered by email within minutes.
Questions about the Norton Shores, MI pack?
Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.
Roofing questions: Norton Shores, MI
Do you need a permit to replace a roof in Norton Shores, MI?
Yes, a permit is required to replace a roof in Norton Shores, MI. Norton Shores treats re-roofing as permit work with no size or cost threshold. Its Building FAQs say "Permits are usually required for the following:" and list "Renovations (garage conversions, basement furnishings, kitchen expansions, re-roofing, etc.)", and among the jobs needing a permit name the work to "apply roofing materials". The Roofing Handout says "The Michigan State Building Code requires a Building Permit for roofing work. R105.1" Under state law "A building permit is not required for ordinary repairs of a building or structure", and the act does not define ordinary repairs; for a small patch, call the Building Division (231-799-6801) before starting.
Is ice & water shield required in Norton Shores, MI?
Yes. Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Norton Shores's building ordinance, City Code Chapter 8 (read in full), states nothing further on ice barrier.
Is drip edge required in Norton Shores, MI?
Yes. Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Norton Shores's building ordinance, City Code Chapter 8 (read in full), states nothing further on drip edge.
Can you roof over an existing roof in Norton Shores, MI?
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." The city's Roofing Handout says "New roof coverings shall not be installed without first removing existing roof coverings for the 4 conditions," citing the code's reroofing section, and states no different layer count. Norton Shores's own building ordinance, City Code Chapter 8 (Buildings and Building Regulations), was read in full: it designates the enforcing agency and covers electrical work, flood damage prevention, swimming pools and rental property, and it touches nothing in the reroofing section, so the state limit applies unchanged.
Do roofing contractors need a license or registration in Norton Shores, MI?
Yes.
What building code does Norton Shores, MI use?
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the City of Norton Shores as its own building code enforcer. City Code Chapter 8 says "the fire department shall act as the building official of the city" and designates it the enforcing agency under the state construction code act, without naming an edition; the city's Roofing Handout is headed "MICHIGAN RESIDENTIAL CODE 2015". Chapter 8 (Buildings and Building Regulations) was read in full; its only residential code text supplies flood hazard content for Table R301.2(1) of the Michigan Residential Code.