Permitting Authorities / Municipality of Monroeville - Building & Engineering Department

Do you need a permit to replace a roof in Municipality of Monroeville, PA?

Adopted code

Municipality of Monroeville - Building & Engineering Department

The Municipality of Monroeville's Building & Engineering Department, at the municipal building, 2700 Monroeville Boulevard, administers the Uniform Construction Code for the Municipality and takes building permit applications, including for roof work, online, in person or by mail. The Pennsylvania Uniform Construction Code applies statewide, but the Pennsylvania Construction Code Act (Act 45 of 1999) says the Act "shall not apply to" "Repairs to residential buildings, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" (section 104(b)(6)).

Roof code checklist: Municipality of Monroeville, PA

ItemAnswerCode citeSourceVerified
Permit to replace a roofNot published
Repair permit thresholdPublishedpacodeandbulletin.gov2026-10-06
Layer limit / roof-overPublishedR908.3.1.1pacodeandbulletin.gov2026-10-06
Deck & sheathingPublishedR905.2.1pacodeandbulletin.gov2026-10-06
Drip edgeNot published
Ice & water shieldNot published
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNot published
Wind design criteriaNot published
Adopted codePublishedSec. 176-1pacodeandbulletin.gov2026-10-06
Contractor license / registrationYespalegis.us2026-10-06
Sales & use taxPublishedpa.gov2026-10-06

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Municipality of Monroeville, Pennsylvania
Jurisdiction type
city
Address
2700 Monroeville Boulevard, Monroeville, PA 15146
Contact
  • url: https://www.monroeville.pa.us/159/Building-Engineering
  • phone: 412-856-3340
Permit portal
Contractor registration required
Required
Permit process note
Read October 6, 2026: the Building & Engineering Department's page lists, under "Building & Fire Code Permits Are Required For:", "Roof Replacements/Solar Panels," offers a "Residential Roof" permit with its own list of requirements and forms, and lists "Roof/Solar Panels" among the permits that can be applied for online. It says "A Building permit application is required to be completed submitted and approved prior to the start of ANY job." The Municipality's building permit application lists "REPAIR OR REPLACEMENT (ROOF/POOL)" as a type of improvement. The Municipality's 2026 fee ordinance (Ordinance No. 2812, enacted December 9, 2025), in its Section 2, "Roof Replacement, Repair and Alteration," says "The permit fee for replacement, repair or alteration of the roof of an existing structure shall be as follows:" and adds "Permit not required for residential shingle replacement only," then sets $50.00 for "Structures classified in residential use group categories." The Department's building permit requirements sheet (updated 7/2021) heads its roof list "Roof (COMMERCIAL MUST APPLY IN ALL CASES)." So the Department's page names roof replacement as permit work without qualification, while the fee ordinance says no permit is required for residential shingle replacement only; this record does not decide which the Department applies to a given house. This record does not answer whether an ordinary house reroof needs a permit in Monroeville: it does not decide which of the Municipality's statements applies to an ordinary house reroof, or what "shingle replacement only" covers. Under state law, Act 45 says the Act "shall not apply to" "Alterations to residential buildings which do not make structural changes or changes to means of egress, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" or to "Repairs to residential buildings, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" (section 104(b)(5) and (6)). The Department of Labor and Industry's register of municipal code change ordinances lists one Monroeville ordinance, which "Requires a building permit for residential utility and miscellaneous use structures larger than 120 sq. ft. or for such structures that are 120 sq. ft. or less, when served by electrical, gas or plumbing systems," with an approval letter mailed March 28, 2005, and enacted May 10, 2005; it names no roof work. In practice, get the Building & Engineering Department's answer in writing (412-856-3340) before starting a residential reroof. Applications go in through the Municipality's online permit portal or in person or by mail to the Building & Engineering Department, 2700 Monroeville Boulevard, Monroeville, PA 15146; the roof list on the requirements sheet asks for the building permit application, the zoning application, two sets of drawings with material lists or specification sheets, and workers' compensation. The page says "Applications can take between 15 and 30 business days for review and processing" and that inspections should be scheduled at least 24 hours in advance. The municipal building is open Monday through Friday, 8:30 a.m. to 4 p.m.
Adopted code
The 2021 International Residential Code, as adopted by the State in the Pennsylvania Uniform Construction Code (UCC). 34 Pa. Code 403.21(a)(7) adopts "The 'International Residential Code of 2021,' except that:" followed by the State's list of exclusions and modifications, effective January 1, 2026 (55 Pa.B. 7701). None of the State's changes touches Chapter 9, Roof Assemblies, or Section R803, Roof Sheathing, so those apply as the International Code Council publishes them. Work on existing buildings is also pointed to the State's existing-building code: "The repair, alteration, change of occupancy, addition and relocation of existing buildings must comply with Chapter 34 of the 'International Building Code of 2021' or with the 'International Existing Building Code of 2021'" (34 Pa. Code 403.21(f)). The UCC is the minimum everywhere in the state: "no municipality may propose or enact any ordinance which is less than the minimum requirement of the Uniform Construction Code" (Pennsylvania Construction Code Act, Act 45 of 1999, section 503(b)). The Act also lists work it "shall not apply to", including "Alterations to residential buildings which do not make structural changes or changes to means of egress" or to "Repairs to residential buildings," in each case "except as might be required by ordinances" kept in force under section 303(b)(1) or adopted under section 503 (Act 45 section 104(b)(5) and (6); 34 Pa. Code 403.1(b)(8) and (9)). The Act defines a repair as "The reconstruction or renewal of any part of an existing building for the purpose of its maintenance." So whether the code's roofing rules reach a given house reroof depends on the municipality's own ordinances. Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 of the Municipal Code, Construction Codes, Uniform (Sections 176-1 to 176-8, Ord. No. 2300 as amended), read in full, adopts the Uniform Construction Code "as amended from time to time" as the Municipal Building Code; its only amendment, Section 176-8, concerns accessory utility and miscellaneous structures, and it names no roof work. Section 176-5 affirms building code ordinances adopted "on or before July 1, 1999, and which equal or exceed the requirements of the code," and Chapter 162 of the Municipal Code, Building Construction, read in full, still adopts the "BOCA National Building Code/1996, Thirteenth Edition" (Section 162-1) and the "CABO One and Two Family Dwelling Code, 1995 Edition" (Section 162-7); its amendments to those codes name no roof work. The Department's pages name no code edition, and this record has not read the 1996 BOCA or 1995 CABO text, including their permit and roofing provisions. Chapter 267, Occupancy Permits (Ord. No. 2818, 2026), read in full, names the 2021 International Residential Code among the standards for inspecting a dwelling before a change of occupant and says nothing on roof permits. A search of the whole Municipal Code for "roof" found no provision naming roof work as permit work or as exempt. The Municipality's statements on roof permits are quoted in the permit entries of this record.
Repair permit threshold
No square-footage or percentage threshold for roof work was found in Monroeville, and the Municipality's statements on roof permits differ. Read October 6, 2026: the Building & Engineering Department's page lists, under "Building & Fire Code Permits Are Required For:", "Roof Replacements/Solar Panels," offers a "Residential Roof" permit with its own list of requirements and forms, and lists "Roof/Solar Panels" among the permits that can be applied for online. It says "A Building permit application is required to be completed submitted and approved prior to the start of ANY job." The Municipality's building permit application lists "REPAIR OR REPLACEMENT (ROOF/POOL)" as a type of improvement. The Municipality's 2026 fee ordinance (Ordinance No. 2812, enacted December 9, 2025), in its Section 2, "Roof Replacement, Repair and Alteration," says "The permit fee for replacement, repair or alteration of the roof of an existing structure shall be as follows:" and adds "Permit not required for residential shingle replacement only," then sets $50.00 for "Structures classified in residential use group categories." The Department's building permit requirements sheet (updated 7/2021) heads its roof list "Roof (COMMERCIAL MUST APPLY IN ALL CASES)." So the Department's page names roof replacement as permit work without qualification, while the fee ordinance says no permit is required for residential shingle replacement only; this record does not decide which the Department applies to a given house. This record does not answer whether an ordinary house reroof needs a permit in Monroeville: it does not decide which of the Municipality's statements applies to an ordinary house reroof, or what "shingle replacement only" covers. Under state law, Act 45 says the Act "shall not apply to" "Alterations to residential buildings which do not make structural changes or changes to means of egress, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" or to "Repairs to residential buildings, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" (section 104(b)(5) and (6)). The Department of Labor and Industry's register of municipal code change ordinances lists one Monroeville ordinance, which "Requires a building permit for residential utility and miscellaneous use structures larger than 120 sq. ft. or for such structures that are 120 sq. ft. or less, when served by electrical, gas or plumbing systems," with an approval letter mailed March 28, 2005, and enacted May 10, 2005; it names no roof work. State law sets no square-footage or percentage threshold for roof work; any threshold is set locally. The Uniform Construction Code "does not apply to" "Alterations to residential buildings which do not make structural changes or changes to means of egress, except as required by ordinances in effect under sections 303(b)(1) or 503 of the act" or to "Repairs to residential buildings, except as required by ordinances in effect under sections 303(b)(1) and 503 of the act" (34 Pa. Code 403.1(b)(8) and (9)), and "A permit is not required for the exceptions listed in § 403.1(b) (relating to scope) and the following, if the work does not violate a law or ordinance" (34 Pa. Code 403.62(c)). For houses the regulation adds: "An ordinary repair does not require a permit." Its list of work that is not an ordinary repair names cutting away a load-bearing wall, "The removal or cutting of any structural beam or load-bearing support," changes to a required means of egress, and new or relocated piping, wiring or mechanical work (34 Pa. Code 403.62(d)); roofing is not named. A municipality may require more: under Act 45 section 503(c) it "may enact ordinances pursuant to this section which adopt additional code requirements for alterations or repairs to residential buildings," after a public hearing and after filing the proposed ordinance with the Department of Labor and Industry. These rules concern a "Residential building," which the regulation defines as "Detached one-family and two-family dwellings and townhouses which are not more than three stories above grade plane in height with a separate means of egress and their accessory structures" (34 Pa. Code 401.1). Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 (Sections 176-1 to 176-8), Chapter 162 and Chapter 267 of the Municipal Code, read in full, name no roof work as permit work or as exempt; Chapter 162 still adopts the 1996 BOCA and 1995 CABO codes, which Section 176-5 keeps where they "equal or exceed the requirements of the code," and this record has not read their text.
Roof layer limit / recover
Two layers at most where the state code reaches the job. Pennsylvania adopts the 2021 International Residential Code without changing its reroofing section, R908 (34 Pa. Code 403.21(a)(7); the State's list of changes names no Chapter 9 section). Section R908.3.1.1 says "A roof recover shall not be permitted where any of the following conditions occur," and the third condition is "Where the existing roof has two or more applications of any type of roof covering." So one existing layer may be covered once, and a roof that already has two layers is torn off to the deck. The same section also bars a recover "Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing" and "Where the existing roof covering is slate, clay, cement or asbestos-cement tile." The existing-building code the State also adopts, the 2021 International Existing Building Code (34 Pa. Code 403.21(f)), carries the same three conditions in Section 705.2.1.1. These rules bind work the Uniform Construction Code reaches. The Act does not apply to "Repairs to residential buildings" or to alterations that make no structural change, "except as might be required by ordinances" (Act 45 section 104(b)(5) and (6)), so whether R908 binds a particular house reroof turns on that exclusion and on the municipality's own ordinances. Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 of the Municipal Code, Construction Codes, Uniform (Sections 176-1 to 176-8, Ord. No. 2300 as amended), read in full, adopts the Uniform Construction Code "as amended from time to time" as the Municipal Building Code; its only amendment, Section 176-8, concerns accessory utility and miscellaneous structures, and it names no roof work. Section 176-5 affirms building code ordinances adopted "on or before July 1, 1999, and which equal or exceed the requirements of the code," and Chapter 162 of the Municipal Code, Building Construction, read in full, still adopts the "BOCA National Building Code/1996, Thirteenth Edition" (Section 162-1) and the "CABO One and Two Family Dwelling Code, 1995 Edition" (Section 162-7); its amendments to those codes name no roof work. The Department's pages name no code edition, and this record has not read the 1996 BOCA or 1995 CABO text, including their permit and roofing provisions. Chapter 267, Occupancy Permits (Ord. No. 2818, 2026), read in full, names the 2021 International Residential Code among the standards for inspecting a dwelling before a change of occupant and says nothing on roof permits. A search of the whole Municipal Code for "roof" found no provision naming roof work as permit work or as exempt. The Department's pages say nothing on roof layers.
Deck & sheathing requirements
State rules from the base code, where the state code reaches the job. Pennsylvania adopts the 2021 International Residential Code without changing Section R803, Roof Sheathing (34 Pa. Code 403.21(a)(7); the State's changes to Chapter 8 are to ridge framing and attic ventilation). Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels "shall be identified for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans "shall not exceed the values set forth in Table R503.2.1.1(1) or APA E30." For shingles, "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system and the material and equipment loads that will be encountered during installation of the roof covering system" (R908.2). These rules bind work the Uniform Construction Code reaches; the Act does not apply to "Repairs to residential buildings" or to alterations that make no structural change, "except as might be required by ordinances" (Act 45 section 104(b)(5) and (6)). Act 45 section 104(b)(5) excludes alterations "which do not make structural changes or changes to means of egress" and says only that "a structural change does not include a minor framing change needed to replace existing windows or doors"; 34 Pa. Code 403.62(d)(2) lists "The removal or cutting of any structural beam or load-bearing support" as not an ordinary repair. Neither names roof sheathing; this record does not decide whether replacing it is either. Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 of the Municipal Code, Construction Codes, Uniform (Sections 176-1 to 176-8, Ord. No. 2300 as amended), read in full, adopts the Uniform Construction Code "as amended from time to time" as the Municipal Building Code; its only amendment, Section 176-8, concerns accessory utility and miscellaneous structures, and it names no roof work. Section 176-5 affirms building code ordinances adopted "on or before July 1, 1999, and which equal or exceed the requirements of the code," and Chapter 162 of the Municipal Code, Building Construction, read in full, still adopts the "BOCA National Building Code/1996, Thirteenth Edition" (Section 162-1) and the "CABO One and Two Family Dwelling Code, 1995 Edition" (Section 162-7); its amendments to those codes name no roof work. The Department's pages name no code edition, and this record has not read the 1996 BOCA or 1995 CABO text, including their permit and roofing provisions. Chapter 267, Occupancy Permits (Ord. No. 2818, 2026), read in full, names the 2021 International Residential Code among the standards for inspecting a dwelling before a change of occupant and says nothing on roof permits. A search of the whole Municipal Code for "roof" found no provision naming roof work as permit work or as exempt. The Department's pages draw no line for roof sheathing.
Sales & use tax
6% Pennsylvania sales and use tax, with a local tax added on purchases made in Allegheny County (1%) and Philadelphia (2%). On a reroof the roofer pays the tax on the materials and does not add it to the homeowner's bill. The Department of Revenue says: "The Pennsylvania sales tax rate is 6 percent. By law, a 1 percent local tax is added to purchases made in Allegheny County, and 2 percent local tax is added to purchases made in Philadelphia." Roof work is a construction activity: the rule's list of items "presumed to become a permanent part of real estate" includes "Roofing (repairs)" (61 Pa. Code 31.11). For construction activities, "A contractor shall pay tax upon the purchase price ... of all property, including materials, equipment, components and supplies, which he furnishes and installs" (61 Pa. Code 31.12(a)(1)), and the rule's example says the contractor "does not charge sales tax on this transaction to his customer. The contractor may include the tax he must pay in his bid proposal but not as a separately stated item." Apart from limited exceptions set out in the rule, the same holds on jobs for tax-exempt owners: "a contractor erecting a building, repairing a roof, replacing a door for a governmental agency, ... school district, charitable or religious organization, and the like, shall pay tax upon the property which he consumes" (61 Pa. Code 31.13(a)). Everything above is Pennsylvania state law, the same in every municipality. Monroeville is in Allegheny County, where the 1 percent local tax described above is added to purchases made in the county. Its Building & Engineering Department, which administers the Uniform Construction Code there, states nothing on sales tax on the permit pages and fee ordinance read for this record.

Working an insurance claim in Municipality of Monroeville, PA? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Buy this jurisdiction's pack: $12 Delivered by email within minutes.

Questions about the Municipality of Monroeville, PA pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Municipality of Monroeville, PA

When does a roof repair need a permit in Municipality of Monroeville, PA?

No square-footage or percentage threshold for roof work was found in Monroeville, and the Municipality's statements on roof permits differ. Read October 6, 2026: the Building & Engineering Department's page lists, under "Building & Fire Code Permits Are Required For:", "Roof Replacements/Solar Panels," offers a "Residential Roof" permit with its own list of requirements and forms, and lists "Roof/Solar Panels" among the permits that can be applied for online. It says "A Building permit application is required to be completed submitted and approved prior to the start of ANY job." The Municipality's building permit application lists "REPAIR OR REPLACEMENT (ROOF/POOL)" as a type of improvement. The Municipality's 2026 fee ordinance (Ordinance No. 2812, enacted December 9, 2025), in its Section 2, "Roof Replacement, Repair and Alteration," says "The permit fee for replacement, repair or alteration of the roof of an existing structure shall be as follows:" and adds "Permit not required for residential shingle replacement only," then sets $50.00 for "Structures classified in residential use group categories." The Department's building permit requirements sheet (updated 7/2021) heads its roof list "Roof (COMMERCIAL MUST APPLY IN ALL CASES)." So the Department's page names roof replacement as permit work without qualification, while the fee ordinance says no permit is required for residential shingle replacement only; this record does not decide which the Department applies to a given house. This record does not answer whether an ordinary house reroof needs a permit in Monroeville: it does not decide which of the Municipality's statements applies to an ordinary house reroof, or what "shingle replacement only" covers. Under state law, Act 45 says the Act "shall not apply to" "Alterations to residential buildings which do not make structural changes or changes to means of egress, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" or to "Repairs to residential buildings, except as might be required by ordinances in effect pursuant to section 303(b)(1) or adopted pursuant to section 503" (section 104(b)(5) and (6)). The Department of Labor and Industry's register of municipal code change ordinances lists one Monroeville ordinance, which "Requires a building permit for residential utility and miscellaneous use structures larger than 120 sq. ft. or for such structures that are 120 sq. ft. or less, when served by electrical, gas or plumbing systems," with an approval letter mailed March 28, 2005, and enacted May 10, 2005; it names no roof work. State law sets no square-footage or percentage threshold for roof work; any threshold is set locally. The Uniform Construction Code "does not apply to" "Alterations to residential buildings which do not make structural changes or changes to means of egress, except as required by ordinances in effect under sections 303(b)(1) or 503 of the act" or to "Repairs to residential buildings, except as required by ordinances in effect under sections 303(b)(1) and 503 of the act" (34 Pa. Code 403.1(b)(8) and (9)), and "A permit is not required for the exceptions listed in § 403.1(b) (relating to scope) and the following, if the work does not violate a law or ordinance" (34 Pa. Code 403.62(c)). For houses the regulation adds: "An ordinary repair does not require a permit." Its list of work that is not an ordinary repair names cutting away a load-bearing wall, "The removal or cutting of any structural beam or load-bearing support," changes to a required means of egress, and new or relocated piping, wiring or mechanical work (34 Pa. Code 403.62(d)); roofing is not named. A municipality may require more: under Act 45 section 503(c) it "may enact ordinances pursuant to this section which adopt additional code requirements for alterations or repairs to residential buildings," after a public hearing and after filing the proposed ordinance with the Department of Labor and Industry. These rules concern a "Residential building," which the regulation defines as "Detached one-family and two-family dwellings and townhouses which are not more than three stories above grade plane in height with a separate means of egress and their accessory structures" (34 Pa. Code 401.1). Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 (Sections 176-1 to 176-8), Chapter 162 and Chapter 267 of the Municipal Code, read in full, name no roof work as permit work or as exempt; Chapter 162 still adopts the 1996 BOCA and 1995 CABO codes, which Section 176-5 keeps where they "equal or exceed the requirements of the code," and this record has not read their text.

Can you roof over an existing roof in Municipality of Monroeville, PA?

Two layers at most where the state code reaches the job. Pennsylvania adopts the 2021 International Residential Code without changing its reroofing section, R908 (34 Pa. Code 403.21(a)(7); the State's list of changes names no Chapter 9 section). Section R908.3.1.1 says "A roof recover shall not be permitted where any of the following conditions occur," and the third condition is "Where the existing roof has two or more applications of any type of roof covering." So one existing layer may be covered once, and a roof that already has two layers is torn off to the deck. The same section also bars a recover "Where the existing roof or roof covering is water soaked or has deteriorated to the point that the existing roof or roof covering is not adequate as a base for additional roofing" and "Where the existing roof covering is slate, clay, cement or asbestos-cement tile." The existing-building code the State also adopts, the 2021 International Existing Building Code (34 Pa. Code 403.21(f)), carries the same three conditions in Section 705.2.1.1. These rules bind work the Uniform Construction Code reaches. The Act does not apply to "Repairs to residential buildings" or to alterations that make no structural change, "except as might be required by ordinances" (Act 45 section 104(b)(5) and (6)), so whether R908 binds a particular house reroof turns on that exclusion and on the municipality's own ordinances. Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 of the Municipal Code, Construction Codes, Uniform (Sections 176-1 to 176-8, Ord. No. 2300 as amended), read in full, adopts the Uniform Construction Code "as amended from time to time" as the Municipal Building Code; its only amendment, Section 176-8, concerns accessory utility and miscellaneous structures, and it names no roof work. Section 176-5 affirms building code ordinances adopted "on or before July 1, 1999, and which equal or exceed the requirements of the code," and Chapter 162 of the Municipal Code, Building Construction, read in full, still adopts the "BOCA National Building Code/1996, Thirteenth Edition" (Section 162-1) and the "CABO One and Two Family Dwelling Code, 1995 Edition" (Section 162-7); its amendments to those codes name no roof work. The Department's pages name no code edition, and this record has not read the 1996 BOCA or 1995 CABO text, including their permit and roofing provisions. Chapter 267, Occupancy Permits (Ord. No. 2818, 2026), read in full, names the 2021 International Residential Code among the standards for inspecting a dwelling before a change of occupant and says nothing on roof permits. A search of the whole Municipal Code for "roof" found no provision naming roof work as permit work or as exempt. The Department's pages say nothing on roof layers.

Do roofing contractors need a license or registration in Municipality of Monroeville, PA?

Yes.

What building code does Municipality of Monroeville, PA use?

The 2021 International Residential Code, as adopted by the State in the Pennsylvania Uniform Construction Code (UCC). 34 Pa. Code 403.21(a)(7) adopts "The 'International Residential Code of 2021,' except that:" followed by the State's list of exclusions and modifications, effective January 1, 2026 (55 Pa.B. 7701). None of the State's changes touches Chapter 9, Roof Assemblies, or Section R803, Roof Sheathing, so those apply as the International Code Council publishes them. Work on existing buildings is also pointed to the State's existing-building code: "The repair, alteration, change of occupancy, addition and relocation of existing buildings must comply with Chapter 34 of the 'International Building Code of 2021' or with the 'International Existing Building Code of 2021'" (34 Pa. Code 403.21(f)). The UCC is the minimum everywhere in the state: "no municipality may propose or enact any ordinance which is less than the minimum requirement of the Uniform Construction Code" (Pennsylvania Construction Code Act, Act 45 of 1999, section 503(b)). The Act also lists work it "shall not apply to", including "Alterations to residential buildings which do not make structural changes or changes to means of egress" or to "Repairs to residential buildings," in each case "except as might be required by ordinances" kept in force under section 303(b)(1) or adopted under section 503 (Act 45 section 104(b)(5) and (6); 34 Pa. Code 403.1(b)(8) and (9)). The Act defines a repair as "The reconstruction or renewal of any part of an existing building for the purpose of its maintenance." So whether the code's roofing rules reach a given house reroof depends on the municipality's own ordinances. Everything above is Pennsylvania state law, the same in every municipality. Locally, The Municipality of Monroeville administers the code itself: Section 176-1 of the Municipal Code says "This Municipality hereby elects to administer and enforce the provisions of the Pennsylvania Construction Code Act," Section 176-3 provides for "the designation of an employee of the Municipality to serve as the Municipal Code Official," and the Municipality's Building & Engineering Department takes the permit applications. Chapter 176 of the Municipal Code, Construction Codes, Uniform (Sections 176-1 to 176-8, Ord. No. 2300 as amended), read in full, adopts the Uniform Construction Code "as amended from time to time" as the Municipal Building Code; its only amendment, Section 176-8, concerns accessory utility and miscellaneous structures, and it names no roof work. Section 176-5 affirms building code ordinances adopted "on or before July 1, 1999, and which equal or exceed the requirements of the code," and Chapter 162 of the Municipal Code, Building Construction, read in full, still adopts the "BOCA National Building Code/1996, Thirteenth Edition" (Section 162-1) and the "CABO One and Two Family Dwelling Code, 1995 Edition" (Section 162-7); its amendments to those codes name no roof work. The Department's pages name no code edition, and this record has not read the 1996 BOCA or 1995 CABO text, including their permit and roofing provisions. Chapter 267, Occupancy Permits (Ord. No. 2818, 2026), read in full, names the 2021 International Residential Code among the standards for inspecting a dwelling before a change of occupant and says nothing on roof permits. A search of the whole Municipal Code for "roof" found no provision naming roof work as permit work or as exempt. The Municipality's statements on roof permits are quoted in the permit entries of this record.