Permitting Authorities / Tennessee / City of Medina - Building Codes & Permits (Building Permits)
Do you need a permit to replace a roof in Medina, TN?
Adopted code
City of Medina - Building Codes & Permits (Building Permits)
The City of Medina's Building Codes & Permits office, which posts the City's residential and commercial building permit applications, serves the City of Medina, Tennessee (Gibson County), from 201 Highway 45 E North. The City's code adopts the 2018 International Residential Code. This listing covers the office's contact details, the Tennessee contractor licence rule, the state code statements, and the code facts quoted below; it does not cover every local permit rule.
Roof code checklist: Medina, TN
Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.
Jurisdiction
City of Medina, Tennessee
Address
201 Highway 45 E North, Medina, TN 38355
Contact
- url: https://cityofmedinatn.org/departments/building-codes-permits/
- phone: 731-783-3913
Contractor registration required
Required
Registration details
- state_level: STATEWIDE AT $25,000 AND UP: THE LICENCE IS REQUIRED BEFORE BIDDING. Tennessee licenses roofing through the Board for Licensing Contractors. Tennessee Code 62-6-102 defines "Roofing work" as "the act of removing, installing, repairing or otherwise maintaining any covering to any at- or above-grade structure for the purpose of providing weather proof protection or ornamental enhancement to such structure." It defines "Contractor" to include a "roofing subcontractor where the total cost of the roofing portion of the construction project is twenty-five thousand dollars ($25,000) or more". Rule 0680-01-.24(1) provides: "a subcontractor is required to be licensed in order to perform electrical, plumbing, heating ventilation, air conditioning, and roofing work when the amount is twenty-five thousand dollars ($25,000.00) or more". The Department of Commerce and Insurance states: "A Tennessee contractor's license is required BEFORE bidding or offering a price, for projects $25,000 and up (includes materials and labor), as a prime (general) contractor". Separately, Tennessee Code 62-6-501 excludes from "home improvement" any job "for which the contract price is three thousand dollars ($3,000) or less". Whether the home improvement licence law reaches a particular county or a job under $25,000 was not established here: the Board for Licensing Contractors can say whether it applies. Statute text is the FindLaw copy of the Tennessee Code marked "Current as of January 02, 2024"; rule text is the Cornell LII copy of the Tennessee Compilation of Rules and Regulations, read on Nov 13, 2026. This record did not read later session laws or rule amendments.
Adopted code
STATE FRAME (Tennessee Code 68-120-101 and Rule 0780-02-23). Tennessee has no single residential code for every roof in every town. Section 68-120-101(b)(1)(A) provides: "The standards established pursuant to subsection (a) apply to municipal, county, state and private buildings, including one-family and two-family dwellings, unless otherwise provided by statute." Rule 0780-02-23-.02(1) sets the state minimum for "the construction of one (1) and two (2) family dwellings, townhouses, and additions thereto of thirty (30) square feet or more of interior space in the State of Tennessee" as "International Residential Code (IRC), 2018 edition". Two provisions take a roof replacement on an existing one- or two-family dwelling outside that state minimum. First, section 68-120-101(c) provides that the standards "do not apply to: (1) Renovations of existing one-family and two-family dwellings". Second, rule 0780-02-23-.01(1)(b) provides: "The term 'construction' shall not be construed to include excavation, site preparation or renovation.", and rule 0780-02-23-.01(1)(j) lists "reroofing" among the work it defines as renovation. Separately, section 68-120-101(b)(1)(B)(i) lets a county or municipality vote itself out of the state one- and two-family standards "by a two-thirds" vote; a county's vote reaches only areas outside its cities. Where a local government certifies to the state fire marshal that it adopts and enforces its own building construction and fire safety codes, section 68-120-101(b)(2) provides that "Such standards do not apply" to most buildings within its jurisdiction (not state buildings, educational occupancies, or occupancies the fire marshal inspects for licensure), and section 68-120-101(b)(5)(A) restores the state standards if the local publications "are not current within seven (7) years of the date of the latest editions of the publications, unless otherwise approved by the state fire marshal in writing; provided, however, that nothing in this subdivision (b)(5)(A) shall require a local government to adopt a standard more stringent than the standards enforced by the state fire marshal, pursuant to this section, or to adopt a mandatory sprinkler requirement for one-family and two-family dwellings". So under these provisions the state standards, including the 2018 IRC minimum, do not apply to a re-roof of an existing one- or two-family house. These provisions do not say whether a town's own code reaches a re-roof. Tennessee Code 6-54-502(a) lets a municipality "adopt by reference any code or portions of any code", so the answer turns on what the town itself adopted and amended. For new one- and two-family construction and additions of 30 square feet or more of interior space, the 2018 IRC is the state minimum, and section 68-120-101(b) sets where the state standards apply and where they do not. The renovation exemption does not reach apartment or commercial buildings. Statute text is the FindLaw copy of the Tennessee Code marked "Current as of January 02, 2024"; rule text is the Cornell LII copy of the Tennessee Compilation of Rules and Regulations, read on Nov 13, 2026. This record did not read later session laws or rule amendments. Section 12-101 of the Medina City Code, in the compilation the City publishes, adopts the International Residential Code, "2018 edition, including Appendices A, B, C, G, and J, as prepared and adopted by the International Code Council, is hereby adopted and incorporated by reference as part of Medina City Code". The section's history note lists Ord. #20-01, May 2020 as the latest ordinance. Section 12-102 lists nine modifications.
Drip edge
Required — Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). The City adopted the 2018 International Residential Code via Chapter 1 of Title 12 of the Medina City Code; that instrument, read in full in the compilation the City publishes (sections 12-101 through 12-104, including the nine modifications in 12-102), does not amend R905.2.8.5, so the code's drip-edge requirement stands as enacted local law.
About drip edge
Ice & water shield
Not required — Section 12-102(4) of the Medina City Code, modifying the 2018 International Residential Code, inserts in Table R301.2(1): "Ice Barrier Underlayment Required - No".
About ice & water barrier
Impact-resistant roofing
Not required — Chapter 1 of Title 12 of the Medina City Code (sections 12-101 through 12-104), adopting the 2018 International Residential Code, was read in full. The terms UL 2218, Class 4, impact and hail appear zero times in it, and its nine modifications in section 12-102 do not address roof coverings.
Wind design criteria
Table R301.2(1) as filled in by section 12-102(4) of the Medina City Code: ground snow load 10; wind speed 90; wind topographic effects no; seismic design category D1; subject to damage from weathering moderate; frost line depth 12 inches; subject to damage from termites very heavy.
Roof layer limit / recover
The City adopted the 2018 International Residential Code via Chapter 1 of Title 12 of the Medina City Code, which, read in full (sections 12-101 through 12-104), does not amend Chapter 9 sections R907 or R908. Base-code rule, read at 2018 International Residential Code Section R908.3.1.1, Roof recover not allowed, and quoted here rather than left behind the ICC paywall: a roof recover "shall not be permitted" where "the existing roof has two or more applications of any type of roof covering." One existing layer may be recovered; a second existing layer means a tear-off to the deck.
Local roofing hub
More roof permit pages in Tennessee
Related guides
Working an insurance claim in Medina, TN? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).
Code items like drip edge and ice & water shield are what adjusters ask you to document.
Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.
Questions about the Medina, TN pack?
Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.
Roofing questions: Medina, TN
Is ice & water shield required in Medina, TN?
No. Section 12-102(4) of the Medina City Code, modifying the 2018 International Residential Code, inserts in Table R301.2(1): "Ice Barrier Underlayment Required - No".
Is drip edge required in Medina, TN?
Yes. Drip edge is required at eaves and rake edges of shingle roofs (IRC R905.2.8.5). The City adopted the 2018 International Residential Code via Chapter 1 of Title 12 of the Medina City Code; that instrument, read in full in the compilation the City publishes (sections 12-101 through 12-104, including the nine modifications in 12-102), does not amend R905.2.8.5, so the code's drip-edge requirement stands as enacted local law.
Can you roof over an existing roof in Medina, TN?
The City adopted the 2018 International Residential Code via Chapter 1 of Title 12 of the Medina City Code, which, read in full (sections 12-101 through 12-104), does not amend Chapter 9 sections R907 or R908. Base-code rule, read at 2018 International Residential Code Section R908.3.1.1, Roof recover not allowed, and quoted here rather than left behind the ICC paywall: a roof recover "shall not be permitted" where "the existing roof has two or more applications of any type of roof covering." One existing layer may be recovered; a second existing layer means a tear-off to the deck.
Do roofing contractors need a license or registration in Medina, TN?
Yes.
What building code does Medina, TN use?
STATE FRAME (Tennessee Code 68-120-101 and Rule 0780-02-23). Tennessee has no single residential code for every roof in every town. Section 68-120-101(b)(1)(A) provides: "The standards established pursuant to subsection (a) apply to municipal, county, state and private buildings, including one-family and two-family dwellings, unless otherwise provided by statute." Rule 0780-02-23-.02(1) sets the state minimum for "the construction of one (1) and two (2) family dwellings, townhouses, and additions thereto of thirty (30) square feet or more of interior space in the State of Tennessee" as "International Residential Code (IRC), 2018 edition". Two provisions take a roof replacement on an existing one- or two-family dwelling outside that state minimum. First, section 68-120-101(c) provides that the standards "do not apply to: (1) Renovations of existing one-family and two-family dwellings". Second, rule 0780-02-23-.01(1)(b) provides: "The term 'construction' shall not be construed to include excavation, site preparation or renovation.", and rule 0780-02-23-.01(1)(j) lists "reroofing" among the work it defines as renovation. Separately, section 68-120-101(b)(1)(B)(i) lets a county or municipality vote itself out of the state one- and two-family standards "by a two-thirds" vote; a county's vote reaches only areas outside its cities. Where a local government certifies to the state fire marshal that it adopts and enforces its own building construction and fire safety codes, section 68-120-101(b)(2) provides that "Such standards do not apply" to most buildings within its jurisdiction (not state buildings, educational occupancies, or occupancies the fire marshal inspects for licensure), and section 68-120-101(b)(5)(A) restores the state standards if the local publications "are not current within seven (7) years of the date of the latest editions of the publications, unless otherwise approved by the state fire marshal in writing; provided, however, that nothing in this subdivision (b)(5)(A) shall require a local government to adopt a standard more stringent than the standards enforced by the state fire marshal, pursuant to this section, or to adopt a mandatory sprinkler requirement for one-family and two-family dwellings". So under these provisions the state standards, including the 2018 IRC minimum, do not apply to a re-roof of an existing one- or two-family house. These provisions do not say whether a town's own code reaches a re-roof. Tennessee Code 6-54-502(a) lets a municipality "adopt by reference any code or portions of any code", so the answer turns on what the town itself adopted and amended. For new one- and two-family construction and additions of 30 square feet or more of interior space, the 2018 IRC is the state minimum, and section 68-120-101(b) sets where the state standards apply and where they do not. The renovation exemption does not reach apartment or commercial buildings. Statute text is the FindLaw copy of the Tennessee Code marked "Current as of January 02, 2024"; rule text is the Cornell LII copy of the Tennessee Compilation of Rules and Regulations, read on Nov 13, 2026. This record did not read later session laws or rule amendments. Section 12-101 of the Medina City Code, in the compilation the City publishes, adopts the International Residential Code, "2018 edition, including Appendices A, B, C, G, and J, as prepared and adopted by the International Code Council, is hereby adopted and incorporated by reference as part of Medina City Code". The section's history note lists Ord. #20-01, May 2020 as the latest ordinance. Section 12-102 lists nine modifications.