Permitting Authorities / Wisconsin / City of Green Bay, Wisconsin - Department of Community & Economic Development, Inspection Division (Building Permits & Inspections)

Do you need a permit to replace a roof in Green Bay, WI?

Adopted code

City of Green Bay, Wisconsin - Department of Community & Economic Development, Inspection Division (Building Permits & Inspections)

No, Green Bay, WI does not require a permit for like-for-like roof replacement (City of Green Bay, Wisconsin - Department of Community & Economic Development, Inspection Division (Building Permits & Inspections)). Green Bay's Inspection Division states that building permits are required for most projects except purely cosmetic work such as painting and flooring, but its own roofing/siding FAQ carves re-roofing out for one- and two-family dwellings outside historic residential areas. Where a roofing permit IS required (three or more dwelling units, or a historic residential area), inspections are requested through the City's online Inspection Request Form or by calling 920-448-3300 during business hours, and a project number is required in order to schedule. Owners and contractors are directed to call 920-448-3300 or email inspmail@greenbaywi.gov to confirm whether a specific address is historic and whether a permit is required.

Roof code checklist: Green Bay, WI

ItemAnswerCode citeSourceVerified
Permit to replace a roofNogreenbaywi.gov2026-07-25
Repair permit thresholdPublishedgreenbaywi.gov2026-07-25
Layer limit / roof-overPublisheddocs.legis.wisconsin.gov2026-08-31
Deck & sheathingPublisheddocs.legis.wisconsin.gov2026-07-25
Drip edgeNoR905.2.8.5docs.legis.wisconsin.gov2026-07-25
Ice & water shieldYesdocs.legis.wisconsin.gov2026-08-31
Mid-roof inspectionNogreenbaywi.gov2026-07-25
Impact-resistant (Class 4) roofingNodocs.legis.wisconsin.gov2026-07-25
Wind design criteriaPublisheddocs.legis.wisconsin.gov2026-07-25
Adopted codePublished§ 101.65docs.legis.wisconsin.gov2026-07-25
Contractor license / registrationYesdocs.legis.wisconsin.gov2026-07-25
Sales & use taxPublished§ 77.70revenue.wi.gov2026-07-25

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
City of Green Bay, Wisconsin
Jurisdiction type
city
Address
Green Bay, WI
Contact
  • url: https://www.greenbaywi.gov/312/Building-Permits-Inspections
  • phone: 920-448-3300
  • email: inspmail@greenbaywi.gov
Roofing permit required
Not required
Contractor registration required
Required
Registration details
  • license: STATE credential, not a Green Bay one. Wis. Admin. Code § SPS 305.31(1) provides that no person may obtain a building permit for a one- or two-family dwelling unless that person either (a) holds a DSPS-issued Dwelling Contractor certification or Dwelling Contractor -- Restricted certification, or (b) "[h]olds or engages, as an employee, a person who holds a certification issued by the department as a dwelling contractor qualifier." Wis. Stat. § 101.65(1m) is the statutory hook that makes this a precondition local permit offices must check: a municipality "[m]ay not issue a building permit to a person who is required to be certified under s. 101.654 unless that person, on applying for a building permit, produces a certificate issued by the department or other evidence satisfactory to the department showing that the person is in compliance with s. 101.654." There is no separate Wisconsin roofing-contractor licence -- roofing is one of the subject areas covered by the single, general DSPS Dwelling Contractor / Dwelling Contractor Qualifier scheme. The DCQ credential requires at least 12 hours of an approved initial qualifier course in dwelling construction within one year before application (DSPS form fm3097). Green Bay administers this check but cannot substitute its own credential scheme (Wis. Stat. § 101.65(1c)). GREEN BAY-SPECIFIC WRINKLE: because Green Bay does not require a building permit for an ordinary one- or two-family re-roof (see repair_permit_threshold), the § 101.65(1m) permit-counter check never fires for that work -- but the DSPS credentialing obligation itself is independent of whether a local permit is pulled.
Permit process note
Green Bay's Inspection Division states that building permits are required for most projects except purely cosmetic work such as painting and flooring, but its own roofing/siding FAQ carves re-roofing out for one- and two-family dwellings outside historic residential areas. Where a roofing permit IS required (three or more dwelling units, or a historic residential area), inspections are requested through the City's online Inspection Request Form or by calling 920-448-3300 during business hours, and a project number is required in order to schedule. Owners and contractors are directed to call 920-448-3300 or email inspmail@greenbaywi.gov to confirm whether a specific address is historic and whether a permit is required.
Adopted code
STATE-GOVERNED, NOT CITY-SET. Green Bay has no authority to adopt or amend a different residential building code. Wisconsin's residential code is not a straight IRC adoption: it is the Wisconsin Uniform Dwelling Code (UDC), Wis. Admin. Code ch. SPS 321, drafted by Wisconsin and promulgated by the Department of Safety and Professional Services (DSPS) under Wis. Stat. ch. 101, subch. II. SPS 321.01 (Scope): "The provisions of this chapter shall apply to the design and construction of all one- and 2-family dwellings." The roof-coverings section, SPS 321.28 (Weather Protection for Roofs), was most recently amended by CR 15-041, effective 2016-01-01. Preemption: Wis. Stat. § 101.65(1)(a) lets a municipality "[s]ubject to sub. (1c), exercise jurisdiction over the construction and inspection of new dwellings by passage of ordinances," and § 101.65(1c) provides that a municipality "[m]ay not make or enforce an ordinance under sub. (1) that is applied to a dwelling and that does not conform to this subchapter and the uniform dwelling code adopted by the department under this subchapter." That is a conformity (match/non-match) test, not a minimum floor -- the section contains no "may be more restrictive" carve-out -- so Green Bay applies SPS 321 verbatim for one- and two-family dwellings. Note that SPS 321 governs one- and two-family dwellings only. Roofing on buildings of three or more units, and other commercial work, falls under the Wisconsin Commercial Building Code (Wis. Admin. Code chs. SPS 361-366, adopting the IBC), a different chapter that this record does not cover.
Drip edge
Not required — STATE-GOVERNED, NOT CITY-SET, and a genuine Wisconsin/IRC divergence rather than a research gap. Wis. Admin. Code § SPS 321.28 ("Weather Protection for Roofs"), subsections (1) through (7) read in full, contains no drip-edge-at-eaves-or-rakes requirement anywhere. Wisconsin's UDC is Wisconsin-drafted, not an IRC clone, and it has no counterpart to IRC R905.2.8.5. The only two occurrences of "drip edge" in all of ch. SPS 321 are inapplicable to roof edges: SPS 321.30(8), a chimney-cap detail ("Chimney caps shall have a minimum thickness of 2 inches, shall slope outwards away from the flue, and shall provide a one-inch overhang and drip edge on all sides"), and a deck ledger-board flashing detail in ch. SPS 325 Appendix B. Manufacturer instructions can still require drip edge as a condition of the shingle warranty, and SPS 321.28(3)(a) requires asphalt shingles to be installed per those instructions; but there is no code mandate as such, and Green Bay may not add one for a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). About drip edge
Ice & water shield
Required — STATE-GOVERNED, NOT CITY-SET, but SCOPE-LIMITED BY ROOF SLOPE -- read the trigger before pricing the job. Wis. Admin. Code § SPS 321.28(4)(a) requires ice dam protection on shingled or shake roofs that extend over a heated area of the dwelling or an attached garage AND that have a slope of 4:12 or less; the protection must be sheet metal or a product labeled as meeting ASTM D1970. Wisconsin's UDC therefore does not impose the IRC's across-the-board cold-climate ice barrier on steeper roofs -- it is a Wisconsin-drafted rule, not an IRC clone. Extent, verbatim, SPS 321.28(4)(b): the ice dam protection "shall extend at least 30 inches up the roof slope from the roof edge and at least 12 inches up the roof slope beyond the inner face of the exterior wall." That is a different measurement convention from the IRC's "24 inches inside the exterior wall line" -- do not substitute IRC ice-barrier language on a Wisconsin job. Green Bay may not impose a different ice-barrier rule on a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). The mandate genuinely exists in Wisconsin code, but it is the 4:12-or-less slope condition described here, not the bare yes-or-no answer, that governs a given roof. SCOPE -- the same Uniform Dwelling Code limits that govern the layer rule govern this one, because Wis. Admin. Code SPS 320.05 exempts work from the code as a whole rather than from any single section. SPS 320.05(1) excludes dwellings whose construction commenced before the code's effective date, and additions or alterations to such dwellings, unless the municipality has adopted chs. SPS 320 to 325 for that purpose -- whether Green Bay has done so is NOT established by this record. That date is June 1, 1980 for chs. SPS 320, 321, 323, 324 and 325 under SPS 320.03. Wis. Stat. 101.615 states December 1, 1978, but SPS 320.03 assigns that date to ch. SPS 322, the energy chapter; for a reroof, which is governed by chs. SPS 320 and 321, June 1, 1980 is the date that governs. SPS 320.05(3) further excludes "repairs or maintenance to dwellings or dwelling units," and SPS 320.07(61) defines "repair" to include "the replacement of existing fixtures, systems or equipment with the equivalent" fixture, system or equipment. On a dwelling built before 1980, confirm with the City of Green Bay Inspection Division that the ice dam rule applies before pricing it in or out. About ice & water barrier
Mid-roof inspection
Not required — CITY-SPECIFIC administrative practice (permit administration and inspection are the parts of the field Wis. Stat. § 101.65(1)(a), (1)(c) leaves to municipalities and § 101.65(1c) does not preempt). For an ordinary re-roof of a one- or two-family dwelling in Green Bay outside a historic residential area, the City requires no building permit at all (see repair_permit_threshold and roofing_permit_required), so there is no City permit under which any in-progress deck, underlayment, or mid-roof inspection could be called -- and therefore no mid-roof inspection to schedule. Where a permit IS triggered (a building of three or more units, or a property in a historic residential area), inspections are scheduled through the City's online Inspection Request Form or by calling the Inspection Division at 920-448-3300, and a project number is required to schedule; this record does not state which inspection stages the City calls for on those permitted jobs.
Impact-resistant roofing
Not required — No impact-resistance mandate applies in Green Bay. Wis. Admin. Code § SPS 321.28 ("Weather Protection for Roofs"), the UDC's roof-coverings section, contains no UL 2218 reference, no "Class 4 impact" reference, and no hail- or impact-rating requirement anywhere in subsections (1) through (7); its catch-all, SPS 321.28(5), reads "All roof coverings not otherwise addressed in this section shall be installed in accordance with the manufacturer's instructions or a national standard recognized by the department," which sets no impact class. Green Bay cannot add such a requirement for a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). Impact-resistant shingles remain a voluntary, insurer-driven upgrade in this market rather than a code obligation. (Note that any ASTM E108 / UL 790 "Class A/B/C" designation encountered on a Wisconsin job is a FIRE rating and is not evidence of an impact requirement.)
Repair permit threshold
CITY-SPECIFIC, and unusually permissive. The City of Green Bay's own published FAQ "Do I need a permit for roofing or siding?" answers that a permit is required for roofing and siding "only on a 3 or more unit building or within a historic residential area." So an ordinary re-roof of a one- or two-family dwelling outside a historic district needs no City of Green Bay building permit, at any square footage -- there is no area or bundle-count threshold to cross. The two triggers that DO require a permit are (1) the building having three or more dwelling units (which also moves the technical requirements out of the Uniform Dwelling Code and into the Wisconsin Commercial Building Code), and (2) the property being in a historic residential area. The FAQ directs owners to call the inspection department at 920-448-3300 to verify whether a specific property is historic and whether a building permit is required. NOTE: the absence of a City permit does not waive the substantive code -- SPS 321.28 still applies to the work as a matter of state law, and the state Dwelling Contractor credential requirement (see contractor_registration_required) is a DSPS licensing obligation independent of whether a local permit is pulled.
Wind design criteria
STATE-GOVERNED, NOT CITY-SET. Wisconsin's UDC uses a prescriptive pounds-per-square-foot system plus a statewide snow-load zone map, NOT the IRC's county-by-county "ultimate design wind speed (mph)" table -- do not translate it into an mph figure. Wis. Admin. Code § SPS 321.02(1)(c) requires dwellings to be designed to withstand "either a horizontal and uplift pressure of 20 pounds per square foot acting over the surface area or the wind loads determined in accordance with ASCE 7-05, Minimum Design Loads for Buildings and Other Structures." Snow: SPS 321.02(1)(b)2. -- "Roofs shall be designed and constructed to support the minimum snow loads listed on the zone map" (Figure 321.02), a statewide zone map rather than a single statewide number, so a Green Bay/Brown County ground snow load must be read off that figure; this record does not state a numeric value for Green Bay. Fastening: SPS 321.02(3)(h) -- "All building components shall be fastened to withstand the dead load, live load, snow load, and wind load," per the Table 321.02-2 fastener schedule, with engineered alternatives allowed.
Roof layer limit / recover
STATE-GOVERNED, NOT CITY-SET -- the rule is the same in Green Bay as everywhere else in Wisconsin, for the one- and two-family dwellings the Uniform Dwelling Code reaches -- which is not all of them; read SCOPE below before applying it to an older house. Wis. Admin. Code § SPS 321.28(6) prohibits re-covering (i.e., forces a full tear-off) when any of the following is true: the existing roof covering is water-soaked or has deteriorated to the point that it is not an adequate base for additional roofing; the existing roof covering is wood shake, slate, clay, cement, or asbestos-cement tile; or the existing roof already has two or more applications of roofing. Practical effect: at most one overlay over one existing layer, for a maximum of two total applications of roofing, and only when the existing covering is sound and is not shake, slate, clay, cement, or asbestos-cement tile. Green Bay cannot impose a different layer limit for a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). SCOPE -- the Uniform Dwelling Code does not reach every dwelling, and the rule above governs only the ones it does reach. Wis. Admin. Code SPS 320.05(1) provides that the code "shall not apply to dwellings and dwelling units, the construction of which was commenced prior to the effective date of this code, or to additions or alterations to such dwellings." SPS 320.03 fixes that effective date for chs. SPS 320, 321, 323, 324 and 325 at June 1, 1980. The enabling statute carries its own date: Wis. Stat. 101.615 applies the subchapter to "a dwelling the initial construction of which was commenced on or after December 1, 1978." Those two dates are assigned to different chapters rather than standing against one another: SPS 320.03 gives December 1, 1978 as the effective date of ch. SPS 322, the energy chapter, and June 1, 1980 as the effective date of chs. SPS 320 and 321, which carry these roofing rules. For a reroof, June 1, 1980 is the date that governs. A municipality may close the gap itself -- the note to SPS 320.05(1) states that chs. SPS 320 to 325 "may be adopted by a municipality to apply to any additions or alterations to existing dwellings" -- and whether Green Bay has done so is NOT established by this record. Separately, SPS 320.05(3) provides that the code does "not apply to repairs or maintenance to dwellings or dwelling units," and SPS 320.07(61) defines "repair" to include "the replacement of existing fixtures, systems or equipment with the equivalent" fixture, system or equipment, which is a fair description of a like-for-like tear-off and replacement -- while SPS 321.28(6) regulates reroofing by name. Those two provisions are in genuine tension; this record states both and does not adjudicate between them. On a dwelling built before 1980, or on a like-for-like replacement, confirm scope with the City of Green Bay Inspection Division before relying on the layer rule.
Deck & sheathing requirements
STATE-GOVERNED, NOT CITY-SET. Wis. Admin. Code § SPS 321.27(9) ("Roof Sheathing, Boards and Planking"): (a) structural sheathing -- "The allowable loads and spans for structural sheathing shall be in accordance with the grade stamp on the panel."; (b)1. where rafter spacing is 24 inches on center or less, "roof boards may be used that have a minimum thickness of 5/8-inch for solid sheathing and 3/4-inch for spaced sheathing."; (b)2. where rafter spacing exceeds 24 inches on center, "roof boards shall be tongue and groove, at least 1.5 inches thick."; (c) roof planks, as an alternative, shall be tongue-and-groove or splined and "at least 2 inches, nominal, in thickness," and "Planks shall terminate over beams unless the joints are end matched," "The planks shall be laid so that no continuous line of joints will occur except at points of support," and "Planks shall be nailed or fastened to each beam." Note that Wisconsin's UDC, unlike the IRC as amended in some states, does not state a blanket "solidly sheathed deck" mandate for asphalt shingles -- spaced sheathing at 3/4-inch is expressly contemplated at (9)(b)1 -- while SPS 321.28(3)(a) separately requires asphalt shingles to be installed per the manufacturer's instructions, which commonly do require a solid deck.
Sales & use tax
Green Bay's combined sales and use tax rate is 5.5% -- the 5.0% Wisconsin state rate plus the 0.5% Brown County sales and use tax. There is no City of Green Bay municipal sales tax and no special-district add-on: the 0.5% Brown County football stadium tax that formerly applied ended 2016-09-30 and is not part of the current rate. Brown County is one of the counties that has adopted the optional 0.5% county sales and use tax under Wis. Stat. § 77.70.

The permitting authority for the City of Green Bay, Wisconsin (Brown County). For one- and two-family dwellings, roofing technical requirements in Green Bay are set entirely by the Wisconsin Uniform Dwelling Code (UDC), Wis. Admin. Code ch. SPS 321, promulgated statewide by the Department of Safety and Professional Services; Wis. Stat. § 101.65(1c) bars a municipality from making or enforcing a dwelling ordinance that "does not conform to" the UDC, so Green Bay's own role is limited to permit administration, fees, inspections, and non-preempted overlays such as historic-district design review. Green Bay is notable for NOT requiring a building permit for ordinary one- and two-family re-roofing (see roofing_permit_required and repair_permit_threshold).

Hail reports near Green Bay, WI

Reports, last 24 months
14
Largest, last 24 months
1.75 in Jun 24, 2026
Most recent
Jun 24, 2026 1.75 in
Reports, last 5 years
24
5 most recent reports, last 5 years
DateHail sizeDistance
Jun 24, 20261.75 in6 mi WNW
Jun 24, 20261.50 in4 mi WNW
Jun 24, 20261.25 in4 mi W
Jun 24, 20261.00 in5 mi WNW
Apr 13, 20261.25 in2 mi W

Source: NOAA Storm Prediction Center severe weather database and daily storm reports (reports since the start of the current year are preliminary), within 10 miles of Green Bay, WI (Census point). Data through Oct 7, 2026, not updated since. A report is an observation, not a damage record.

Working an insurance claim in Green Bay, WI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Green Bay, WI pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Green Bay, WI

Do you need a permit to replace a roof in Green Bay, WI?

No, Green Bay, WI does not require a permit to replace a roof. CITY-SPECIFIC, and unusually permissive. The City of Green Bay's own published FAQ "Do I need a permit for roofing or siding?" answers that a permit is required for roofing and siding "only on a 3 or more unit building or within a historic residential area." So an ordinary re-roof of a one- or two-family dwelling outside a historic district needs no City of Green Bay building permit, at any square footage -- there is no area or bundle-count threshold to cross. The two triggers that DO require a permit are (1) the building having three or more dwelling units (which also moves the technical requirements out of the Uniform Dwelling Code and into the Wisconsin Commercial Building Code), and (2) the property being in a historic residential area. The FAQ directs owners to call the inspection department at 920-448-3300 to verify whether a specific property is historic and whether a building permit is required. NOTE: the absence of a City permit does not waive the substantive code -- SPS 321.28 still applies to the work as a matter of state law, and the state Dwelling Contractor credential requirement (see contractor_registration_required) is a DSPS licensing obligation independent of whether a local permit is pulled.

Is ice & water shield required in Green Bay, WI?

Yes. STATE-GOVERNED, NOT CITY-SET, but SCOPE-LIMITED BY ROOF SLOPE -- read the trigger before pricing the job. Wis. Admin. Code § SPS 321.28(4)(a) requires ice dam protection on shingled or shake roofs that extend over a heated area of the dwelling or an attached garage AND that have a slope of 4:12 or less; the protection must be sheet metal or a product labeled as meeting ASTM D1970. Wisconsin's UDC therefore does not impose the IRC's across-the-board cold-climate ice barrier on steeper roofs -- it is a Wisconsin-drafted rule, not an IRC clone. Extent, verbatim, SPS 321.28(4)(b): the ice dam protection "shall extend at least 30 inches up the roof slope from the roof edge and at least 12 inches up the roof slope beyond the inner face of the exterior wall." That is a different measurement convention from the IRC's "24 inches inside the exterior wall line" -- do not substitute IRC ice-barrier language on a Wisconsin job. Green Bay may not impose a different ice-barrier rule on a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). The mandate genuinely exists in Wisconsin code, but it is the 4:12-or-less slope condition described here, not the bare yes-or-no answer, that governs a given roof. SCOPE -- the same Uniform Dwelling Code limits that govern the layer rule govern this one, because Wis. Admin. Code SPS 320.05 exempts work from the code as a whole rather than from any single section. SPS 320.05(1) excludes dwellings whose construction commenced before the code's effective date, and additions or alterations to such dwellings, unless the municipality has adopted chs. SPS 320 to 325 for that purpose -- whether Green Bay has done so is NOT established by this record. That date is June 1, 1980 for chs. SPS 320, 321, 323, 324 and 325 under SPS 320.03. Wis. Stat. 101.615 states December 1, 1978, but SPS 320.03 assigns that date to ch. SPS 322, the energy chapter; for a reroof, which is governed by chs. SPS 320 and 321, June 1, 1980 is the date that governs. SPS 320.05(3) further excludes "repairs or maintenance to dwellings or dwelling units," and SPS 320.07(61) defines "repair" to include "the replacement of existing fixtures, systems or equipment with the equivalent" fixture, system or equipment. On a dwelling built before 1980, confirm with the City of Green Bay Inspection Division that the ice dam rule applies before pricing it in or out.

Is drip edge required in Green Bay, WI?

No. STATE-GOVERNED, NOT CITY-SET, and a genuine Wisconsin/IRC divergence rather than a research gap. Wis. Admin. Code § SPS 321.28 ("Weather Protection for Roofs"), subsections (1) through (7) read in full, contains no drip-edge-at-eaves-or-rakes requirement anywhere. Wisconsin's UDC is Wisconsin-drafted, not an IRC clone, and it has no counterpart to IRC R905.2.8.5. The only two occurrences of "drip edge" in all of ch. SPS 321 are inapplicable to roof edges: SPS 321.30(8), a chimney-cap detail ("Chimney caps shall have a minimum thickness of 2 inches, shall slope outwards away from the flue, and shall provide a one-inch overhang and drip edge on all sides"), and a deck ledger-board flashing detail in ch. SPS 325 Appendix B. Manufacturer instructions can still require drip edge as a condition of the shingle warranty, and SPS 321.28(3)(a) requires asphalt shingles to be installed per those instructions; but there is no code mandate as such, and Green Bay may not add one for a one- or two-family dwelling (Wis. Stat. § 101.65(1c)).

Can you roof over an existing roof in Green Bay, WI?

STATE-GOVERNED, NOT CITY-SET -- the rule is the same in Green Bay as everywhere else in Wisconsin, for the one- and two-family dwellings the Uniform Dwelling Code reaches -- which is not all of them; read SCOPE below before applying it to an older house. Wis. Admin. Code § SPS 321.28(6) prohibits re-covering (i.e., forces a full tear-off) when any of the following is true: the existing roof covering is water-soaked or has deteriorated to the point that it is not an adequate base for additional roofing; the existing roof covering is wood shake, slate, clay, cement, or asbestos-cement tile; or the existing roof already has two or more applications of roofing. Practical effect: at most one overlay over one existing layer, for a maximum of two total applications of roofing, and only when the existing covering is sound and is not shake, slate, clay, cement, or asbestos-cement tile. Green Bay cannot impose a different layer limit for a one- or two-family dwelling (Wis. Stat. § 101.65(1c)). SCOPE -- the Uniform Dwelling Code does not reach every dwelling, and the rule above governs only the ones it does reach. Wis. Admin. Code SPS 320.05(1) provides that the code "shall not apply to dwellings and dwelling units, the construction of which was commenced prior to the effective date of this code, or to additions or alterations to such dwellings." SPS 320.03 fixes that effective date for chs. SPS 320, 321, 323, 324 and 325 at June 1, 1980. The enabling statute carries its own date: Wis. Stat. 101.615 applies the subchapter to "a dwelling the initial construction of which was commenced on or after December 1, 1978." Those two dates are assigned to different chapters rather than standing against one another: SPS 320.03 gives December 1, 1978 as the effective date of ch. SPS 322, the energy chapter, and June 1, 1980 as the effective date of chs. SPS 320 and 321, which carry these roofing rules. For a reroof, June 1, 1980 is the date that governs. A municipality may close the gap itself -- the note to SPS 320.05(1) states that chs. SPS 320 to 325 "may be adopted by a municipality to apply to any additions or alterations to existing dwellings" -- and whether Green Bay has done so is NOT established by this record. Separately, SPS 320.05(3) provides that the code does "not apply to repairs or maintenance to dwellings or dwelling units," and SPS 320.07(61) defines "repair" to include "the replacement of existing fixtures, systems or equipment with the equivalent" fixture, system or equipment, which is a fair description of a like-for-like tear-off and replacement -- while SPS 321.28(6) regulates reroofing by name. Those two provisions are in genuine tension; this record states both and does not adjudicate between them. On a dwelling built before 1980, or on a like-for-like replacement, confirm scope with the City of Green Bay Inspection Division before relying on the layer rule.

Do roofing contractors need a license or registration in Green Bay, WI?

Yes. STATE credential, not a Green Bay one. Wis. Admin. Code § SPS 305.31(1) provides that no person may obtain a building permit for a one- or two-family dwelling unless that person either (a) holds a DSPS-issued Dwelling Contractor certification or Dwelling Contractor -- Restricted certification, or (b) "[h]olds or engages, as an employee, a person who holds a certification issued by the department as a dwelling contractor qualifier." Wis. Stat. § 101.65(1m) is the statutory hook that makes this a precondition local permit offices must check: a municipality "[m]ay not issue a building permit to a person who is required to be certified under s. 101.654 unless that person, on applying for a building permit, produces a certificate issued by the department or other evidence satisfactory to the department showing that the person is in compliance with s. 101.654." There is no separate Wisconsin roofing-contractor licence -- roofing is one of the subject areas covered by the single, general DSPS Dwelling Contractor / Dwelling Contractor Qualifier scheme. The DCQ credential requires at least 12 hours of an approved initial qualifier course in dwelling construction within one year before application (DSPS form fm3097). Green Bay administers this check but cannot substitute its own credential scheme (Wis. Stat. § 101.65(1c)). GREEN BAY-SPECIFIC WRINKLE: because Green Bay does not require a building permit for an ordinary one- or two-family re-roof (see repair_permit_threshold), the § 101.65(1m) permit-counter check never fires for that work -- but the DSPS credentialing obligation itself is independent of whether a local permit is pulled.

What building code does Green Bay, WI use?

STATE-GOVERNED, NOT CITY-SET. Green Bay has no authority to adopt or amend a different residential building code. Wisconsin's residential code is not a straight IRC adoption: it is the Wisconsin Uniform Dwelling Code (UDC), Wis. Admin. Code ch. SPS 321, drafted by Wisconsin and promulgated by the Department of Safety and Professional Services (DSPS) under Wis. Stat. ch. 101, subch. II. SPS 321.01 (Scope): "The provisions of this chapter shall apply to the design and construction of all one- and 2-family dwellings." The roof-coverings section, SPS 321.28 (Weather Protection for Roofs), was most recently amended by CR 15-041, effective 2016-01-01. Preemption: Wis. Stat. § 101.65(1)(a) lets a municipality "[s]ubject to sub. (1c), exercise jurisdiction over the construction and inspection of new dwellings by passage of ordinances," and § 101.65(1c) provides that a municipality "[m]ay not make or enforce an ordinance under sub. (1) that is applied to a dwelling and that does not conform to this subchapter and the uniform dwelling code adopted by the department under this subchapter." That is a conformity (match/non-match) test, not a minimum floor -- the section contains no "may be more restrictive" carve-out -- so Green Bay applies SPS 321 verbatim for one- and two-family dwellings. Note that SPS 321 governs one- and two-family dwellings only. Roofing on buildings of three or more units, and other commercial work, falls under the Wisconsin Commercial Building Code (Wis. Admin. Code chs. SPS 361-366, adopting the IBC), a different chapter that this record does not cover.