Permitting Authorities / Charter Township of Clayton - Building Department

Do you need a permit to replace a roof in Charter Township of Clayton, MI?

Adopted code

Charter Township of Clayton - Building Department

The Charter Township of Clayton's Building Department, at the township hall at 2011 South Morrish Road in Swartz Creek, issues building permits and also issues and inspects the electrical, mechanical and plumbing permits in-house. The State of Michigan's Statewide Jurisdiction List names the Charter Township of Clayton as its own building code enforcer. Michigan's single state construction code applies, and for houses that is the 2015 Michigan Residential Code.

Roof code checklist: Charter Township of Clayton, MI

ItemAnswerCode citeSourceVerified
Permit to replace a roofNot published
Repair permit thresholdPublishedclaytontownship.org2026-10-11
Layer limit / roof-overPublishedR908.3.1.1codes.iccsafe.org2026-10-11
Deck & sheathingPublishedR905.2.1codes.iccsafe.org2026-10-11
Drip edgeYesR905.2.8.5codes.iccsafe.org2026-10-11
Ice & water shieldYesR905.1.2ars.apps.lara.state.mi.us2026-10-11
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNoars.apps.lara.state.mi.us2026-10-11
Wind design criteriaNot published
Adopted codePublishedars.apps.lara.state.mi.us2026-10-11
Contractor license / registrationYeslegislature.mi.gov2026-10-11
Sales & use taxPublishedlegislature.mi.gov2026-10-11

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Charter Township of Clayton, Michigan
Jurisdiction type
city
Address
2011 South Morrish Road, Swartz Creek, MI 48473
Contact
  • url: https://claytontownship.org/building-department/
  • phone: 810-635-4433
Contractor registration required
Required
Registration details
  • state_level: Michigan licenses residential maintenance and alteration contractors under the Occupational Code, and that licence "includes the following crafts and trades" among which it names roofing (MCL 339.2404(3)); "A person shall not engage in or attempt to engage in the practice of an occupation regulated under this act" without the licence (MCL 339.601(1)). MCL 339.2403 lists who may work without one, including a project whose "aggregate contract price for the labor, material, and any other items for the undertaking or project is less than $600.00". This record does not decide whether a given roofer falls inside an exemption.
  • city_level: The Clayton Township Building Department's Contractor Registration Form says "Prior to any permits being issued, this information sheet, $15 fee, copy of the responsible party's drivers license and a copy of your license(s) issued from the state will have to be on file." and asks for the contractor and master licence numbers and expiration dates. This record does not decide whether a given roofer falls inside a state exemption.
Permit process note
The Clayton Township Building Department has published nothing specific to roof work. Its page says "All new residences, accessory buildings over 200 sq. ft., pools, decks, signs, remodels, additions, and structural changes require a building permit." and "All new residential construction requires a Soil Erosion Permit or Waiver prior to making a Building Permit application." The state's general permit rule applies: "before construction of a building or structure, the owner, or the owner's builder, architect, engineer, or agent, shall submit an application in writing to the appropriate enforcing agency for a building permit." The same state section says "A building permit is not required for ordinary repairs of a building or structure," without defining ordinary repairs, and the department has published nothing applying either relief to roof work. The page says "Email all permit applications to" the department's coordinator and "All inspections must be called in at least one day before the inspection is needed." Inspections run Monday through Thursday, 8:00 AM to 5:00 PM, and the township office line is 810-635-4433. The department also issues and inspects electrical, mechanical and plumbing permits in-house. The Building Permit Application carries a fee block for the building permit, zoning permit and plan review but the department publishes no fee schedule, so ask for the current fee. The township's codified ordinances, which the township posts on American Legal Publishing, were not read for this record.
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Charter Township of Clayton as its own building code enforcer. The Building Department's page and Building Permit Application name no code edition. The township's codified ordinances are posted on American Legal Publishing and their text was not read for this record, so this record states the 2015 Michigan Residential Code for the reasons above.
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on drip edge. The township's codified ordinances, posted on American Legal Publishing, were not read for this record. About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on ice barrier. The township's codified ordinances, posted on American Legal Publishing, were not read for this record. About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on impact resistance. The township's codified ordinances, posted on American Legal Publishing, were not read for this record.
Repair permit threshold
No size or cost threshold is published. The Clayton Township Building Department page says "All new residences, accessory buildings over 200 sq. ft., pools, decks, signs, remodels, additions, and structural changes require a building permit." and names no roofing work, and its Building Permit Application has no roofing permit type or fee line. Under state law, "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs. For a roof repair or reroof, ask the department (810-635-4433) before starting.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Clayton Township's Building Department page and its Building Permit Application state no layer rule. The township's codified ordinances were not read for this record, so this record states the state rule and does not classify the township's own text.
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on roof sheathing. The township's codified ordinances, posted on American Legal Publishing, were not read for this record.
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." Nothing on Clayton Township's Building Department page changes this.

Working an insurance claim in Charter Township of Clayton, MI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Charter Township of Clayton, MI pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Charter Township of Clayton, MI

When does a roof repair need a permit in Charter Township of Clayton, MI?

No size or cost threshold is published. The Clayton Township Building Department page says "All new residences, accessory buildings over 200 sq. ft., pools, decks, signs, remodels, additions, and structural changes require a building permit." and names no roofing work, and its Building Permit Application has no roofing permit type or fee line. Under state law, "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs. For a roof repair or reroof, ask the department (810-635-4433) before starting.

Is ice & water shield required in Charter Township of Clayton, MI?

Yes. Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on ice barrier. The township's codified ordinances, posted on American Legal Publishing, were not read for this record.

Is drip edge required in Charter Township of Clayton, MI?

Yes. Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Clayton Township's Building Department page and its Building Permit Application were read for a local rule and state nothing further on drip edge. The township's codified ordinances, posted on American Legal Publishing, were not read for this record.

Can you roof over an existing roof in Charter Township of Clayton, MI?

Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Clayton Township's Building Department page and its Building Permit Application state no layer rule. The township's codified ordinances were not read for this record, so this record states the state rule and does not classify the township's own text.

Do roofing contractors need a license or registration in Charter Township of Clayton, MI?

Yes.

What building code does Charter Township of Clayton, MI use?

2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Charter Township of Clayton as its own building code enforcer. The Building Department's page and Building Permit Application name no code edition. The township's codified ordinances are posted on American Legal Publishing and their text was not read for this record, so this record states the 2015 Michigan Residential Code for the reasons above.