Permitting Authorities / Village of Cassopolis - Building Inspections
Do you need a permit to replace a roof in Cassopolis, MI?
Adopted code
Village of Cassopolis - Building Inspections
Yes, a permit is required to replace a roof in Cassopolis, MI, issued by Village of Cassopolis - Building Inspections. In the Village of Cassopolis a building permit application is completed and returned to Village Hall or emailed to the building inspector, and the village's Building/Inspections page says "Make checks payable to Village of Cassopolis." The page names a Building and Rental Inspector, an Electrical Inspector and a Mechanical and Plumbing Inspector, and says the village "has a Construction Board of Appeals" that "only meets when an appeal has been filed." Mechanical and plumbing applications are mailed with payment to the mechanical and plumbing inspector in Sturgis. The village's Master Fee Schedule 2025 lists "Michigan Residential Code 2015" among its building codes and says the inspection fees are those of the state: "Bureau of Construction Codes Inspection fees established under the STILL-DEROSSETT-HALE State Construction Code Act, 1972 PA 230". It posts no roofing-specific fee, permit type or form, so ask the building inspector, at 269-998-2765, what the permit costs for a reroof. Village Hall is at 121 N. Disbrow Street, Cassopolis, MI 49031.
Roof code checklist: Cassopolis, MI
Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.
Jurisdiction
Village of Cassopolis, Michigan
Address
121 N. Disbrow Street, Cassopolis, MI 49031
Contact
- url: https://www.cassopolis-mi.us/services/buildinginspections.php
- phone: 269-998-2765
Roofing permit required
Required
Contractor registration required
Required
Permit process note
In the Village of Cassopolis a building permit application is completed and returned to Village Hall or emailed to the building inspector, and the village's Building/Inspections page says "Make checks payable to Village of Cassopolis." The page names a Building and Rental Inspector, an Electrical Inspector and a Mechanical and Plumbing Inspector, and says the village "has a Construction Board of Appeals" that "only meets when an appeal has been filed." Mechanical and plumbing applications are mailed with payment to the mechanical and plumbing inspector in Sturgis. The village's Master Fee Schedule 2025 lists "Michigan Residential Code 2015" among its building codes and says the inspection fees are those of the state: "Bureau of Construction Codes Inspection fees established under the STILL-DEROSSETT-HALE State Construction Code Act, 1972 PA 230". It posts no roofing-specific fee, permit type or form, so ask the building inspector, at 269-998-2765, what the permit costs for a reroof. Village Hall is at 121 N. Disbrow Street, Cassopolis, MI 49031.
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Village of Cassopolis as its own building code enforcer. Chapter 122 of the village's Code of Ordinances designates the village building inspectors as the enforcing agency. The Village's codified Chapter 122, Article IV (Ord. No. 245, adopted 9-8-2008) adopts "Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition" and provides that "any and all subsequent code change as referenced above be adopted by the Village at the same time as they are by the State of Michigan or the federal government." This directory has not read the 2006 text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. The Village's Master Fee Schedule 2025 lists "Michigan Residential Code 2015" among its building codes.
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on drip edge.
About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on ice barrier.
About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on impact resistance.
Repair permit threshold
The Village of Cassopolis publishes nothing on reroofs and no size line below which a roof job needs no permit. Its Building/Inspections page says "The Village has adopted and enforces the Michigan Building Codes and the International Property Maintenance Code." and tells applicants to "Complete and return to Village Hall or email to building inspector." Its Building Permit Application lists work types including "ALTERATION" and "REPAIR" and names no roofing item. State law requires that before construction of a building or structure, the owner, or the owner's builder, architect, engineer, or agent, shall submit an application in writing to the appropriate enforcing agency for a building permit (MCL 125.1510(1)), defines construction to mean "the construction, erection, reconstruction, alteration, conversion, demolition, repair, moving, or equipping of buildings or structures" (MCL 125.1502a(n)), and says "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510(7)) without defining ordinary repairs; the permit exemptions in the Michigan Residential Code name no roofing. Chapter 122 of the village code designates the enforcing agency and adds no definition of ordinary repairs.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Locally, Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations) was read in full (Articles I to IV: the mechanical, electrical and plumbing enforcing agency articles and the adoption of building regulations): it designates the enforcing agency and adopts the state codes by reference, has no reroofing provision and amends nothing in Section R908. The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). The Building/Inspections page and the building permit application state no layer rule.
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on roof sheathing.
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." Nothing on the Village of Cassopolis's Building/Inspections page or in its Master Fee Schedule 2025 changes this.
Local roofing hub
More roof permit pages in Michigan
Related guides
The Village of Cassopolis issues building permits through its Building/Inspections office, with applications returned to Village Hall at 121 N. Disbrow Street or emailed to the village's building inspector; electrical, mechanical and plumbing work have their own inspectors. Chapter 122 of the village's Code of Ordinances designates the village building inspectors as the enforcing agency under the state construction code act. Michigan's single state construction code applies, and for houses that is the 2015 Michigan Residential Code.
Working an insurance claim in Cassopolis, MI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).
Code items like drip edge and ice & water shield are what adjusters ask you to document.
Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.
Questions about the Cassopolis, MI pack?
Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.
Roofing questions: Cassopolis, MI
Do you need a permit to replace a roof in Cassopolis, MI?
Yes, a permit is required to replace a roof in Cassopolis, MI. The Village of Cassopolis publishes nothing on reroofs and no size line below which a roof job needs no permit. Its Building/Inspections page says "The Village has adopted and enforces the Michigan Building Codes and the International Property Maintenance Code." and tells applicants to "Complete and return to Village Hall or email to building inspector." Its Building Permit Application lists work types including "ALTERATION" and "REPAIR" and names no roofing item. State law requires that before construction of a building or structure, the owner, or the owner's builder, architect, engineer, or agent, shall submit an application in writing to the appropriate enforcing agency for a building permit (MCL 125.1510(1)), defines construction to mean "the construction, erection, reconstruction, alteration, conversion, demolition, repair, moving, or equipping of buildings or structures" (MCL 125.1502a(n)), and says "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510(7)) without defining ordinary repairs; the permit exemptions in the Michigan Residential Code name no roofing. Chapter 122 of the village code designates the enforcing agency and adds no definition of ordinary repairs.
Is ice & water shield required in Cassopolis, MI?
Yes. Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on ice barrier.
Is drip edge required in Cassopolis, MI?
Yes. Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations), the Building/Inspections page and the building permit application were read for a local rule and state nothing further on drip edge.
Can you roof over an existing roof in Cassopolis, MI?
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Locally, Chapter 122 of the Village of Cassopolis Code of Ordinances (Building Regulations) was read in full (Articles I to IV: the mechanical, electrical and plumbing enforcing agency articles and the adoption of building regulations): it designates the enforcing agency and adopts the state codes by reference, has no reroofing provision and amends nothing in Section R908. The Village's codified Chapter 122, Article IV adopts the Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the Village's Master Fee Schedule 2025 lists among its building codes; the 2006 Edition text was not read (see adopted_code). The Building/Inspections page and the building permit application state no layer rule.
Do roofing contractors need a license or registration in Cassopolis, MI?
Yes.
What building code does Cassopolis, MI use?
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." LARA's Statewide Jurisdiction List names the Village of Cassopolis as its own building code enforcer. Chapter 122 of the village's Code of Ordinances designates the village building inspectors as the enforcing agency. The Village's codified Chapter 122, Article IV (Ord. No. 245, adopted 9-8-2008) adopts "Michigan Residential Code (One- and Two-Family Dwellings), 2006 Edition" and provides that "any and all subsequent code change as referenced above be adopted by the Village at the same time as they are by the State of Michigan or the federal government." This directory has not read the 2006 text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. The Village's Master Fee Schedule 2025 lists "Michigan Residential Code 2015" among its building codes.