Permitting Authorities / Charter Township of Bridgeport - Building and Codes Department

Charter Township of Bridgeport - Building and Codes Department

Adopted code

The Charter Township of Bridgeport's Building and Codes Department, at 6740 Dixie Highway in Bridgeport, issues building permits and inspects construction in the township; its counter is open Monday to Thursday, 8:30 a.m. to 11 a.m. and 4:30 p.m. to 5 p.m. Section 8-19 of the Township's Code of Ordinances designates the building inspector as the enforcing agency, and the State of Michigan's jurisdiction list names the Township as its own building code enforcer. Michigan's single state construction code applies, and for houses that is the 2015 Michigan Residential Code.

Roof code checklist: Charter Township of Bridgeport - Building and Codes Department

ItemAnswerCode citeSourceVerified
Permit to replace a roofYesBridgeport-Building-Permits-form.pdf2026-10-03
Repair permit thresholdPublishedBridgeport-Building-Permits-form.pdf2026-10-03
Layer limit / roof-overPublishedR908.3.1.1codes.iccsafe.org2026-10-03
Deck & sheathingPublishedR905.2.1codes.iccsafe.org2026-10-03
Drip edgeYesR905.2.8.5codes.iccsafe.org2026-10-03
Ice & water shieldYesR905.1.2ars.apps.lara.state.mi.us2026-10-03
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNoars.apps.lara.state.mi.us2026-10-03
Wind design criteriaNot published
Adopted codePublishedSec. 8-19ars.apps.lara.state.mi.us2026-10-03
Contractor license / registrationYeslegislature.mi.gov2026-10-03
Sales & use taxPublishedlegislature.mi.gov2026-10-03

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Charter Township of Bridgeport, Michigan (Saginaw County)
Jurisdiction type
city
Address
6740 Dixie Highway, Bridgeport, MI 48722
Contact
  • url: https://bridgeportmi.org/departments/building_and_codes/index.php
  • phone: 989-777-0940 ext. 215
Roofing permit required
Required
Contractor registration required
Required
Permit process note
Bridgeport names roof work as permit work: the Township's Building Permit Application (Rev. 04/2020) lists "Roof" among the types of work, beside Siding, Windows, Deck and Garage. The department's page adds "Before any structure is built, permits must be obtained and plans submitted" and "It is important to first check with the building department for information on required permitting." Questions go to the Building Official at 989-777-0940 ext. 215. The fee sheet the Township links today is dated "EFFECTIVE APRIL 02, 2019": "$1.00 to $2000 - Permit fee is $85.00 which includes one (1) inspection," rising with construction cost (for example $184.00 at $10,000 and $409.00 at $25,000), and residential "PERMITS FEES OVER $100.00 INCLUDE A PLAN REVIEW FEE OF $50.00". The same sheet says "PERMITS FEES OF $100.00 BUT LESS THAN $1000.00 SHALL POST A BOND OF $325.00." Because the sheet is from 2019, confirm the current fee with the department. The application asks for the contractor's license number and warns "A PERMIT WILL BE CANCELED WHEN NO INSPECTIONS ARE REQUESTED OR CONDUCTED WITHIN 180 DAYS OF ISSUANCE". The Township also keeps a Contractor Registration Form that must come with a "Copy of state trade licenses", a picture ID and a "Certificate of insurance".
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." Locally, the Building and Codes Department says it enforces "the Michigan Building Code (MBC), The Michigan Rehabilitation Code for Existing Buildings (MRCEB), the Michigan Residential Code (MRC)" and the other state codes, and Section 8-19 of the Township's code designates the building inspector "to enforce the state construction code." Neither names a different edition. The Township separately adopts the International Property Maintenance Code, 2006 edition, for existing buildings (Section 8-80).
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). The Charter Township of Bridgeport's building permit application, fee sheet and Chapter 8 of its code were read for a local rule and state nothing further on drip edge. About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). The Charter Township of Bridgeport's building permit application, fee sheet and Chapter 8 of its code were read for a local rule and state nothing further on ice barrier. About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." The Charter Township of Bridgeport's building permit application, fee sheet and Chapter 8 of its code were read for a local rule and state nothing further on impact resistance.
Repair permit threshold
No size or cost threshold is published. The Township's Building Permit Application lists "Roof" as a type of work with no size limit, and Chapter 8 of the Code of Ordinances (Buildings and Building Regulations), read in full, sets no repair threshold of its own. The state part: Michigan's construction code act says "A building permit is not required for ordinary repairs of a building or structure" and does not define ordinary repairs. For a small roof repair, ask the Building Official (989-777-0940 ext. 215) before starting.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Locally, the Township's own building ordinance, Chapter 8 of the Bridgeport Code of Ordinances (Buildings and Building Regulations, which designates the enforcing agency, adopts the 2006 property maintenance code with its amendments, and covers flood damage prevention, dangerous buildings and swimming pools), was read in full: it has no roofing provision and amends nothing in Section R908, and the Township's building permit application and fee sheet state no layer rule.
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). The Charter Township of Bridgeport's building permit application, fee sheet and Chapter 8 of its code were read for a local rule and state nothing further on roof sheathing.
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." Nothing on the Charter Township of Bridgeport's permit pages changes this.

Working an insurance claim in Charter Township of Bridgeport - Building and Codes Department? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes.

Questions about the Charter Township of Bridgeport - Building and Codes Department pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources