Permitting Authorities / Bertrand Charter Township - Building Department

Do you need a permit to replace a roof in Charter Township of Bertrand, MI?

Adopted code

Bertrand Charter Township - Building Department

Yes, a permit is required to replace a roof in Charter Township of Bertrand, MI, issued by Bertrand Charter Township - Building Department. Bertrand Charter Township publishes nothing specific to roof work: its Building Department page, Forms and Permits page, building permit application and codified Chapter 6 name no roofing line, no reroof exemption and no size or cost point. With the township silent on reroofs, the state's general permit rule applies: "before construction of a building or structure, the owner, or the owner's builder, architect, engineer, or agent, shall submit an application in writing to the appropriate enforcing agency for a building permit." The same section says "A building permit is not required for ordinary repairs of a building or structure," without defining ordinary repairs, and the township has published no statement applying that relief to roof work. The township's Zoning Ordinance says "A building permit is the written authority as issued by the Building Inspector permitting the construction, moving, alteration or use of a building", the Building Department page says "All of the other inspectors can be reached by the phone number listed on their permit", and the township's agricultural-exemption sheet gives the building department's line, 269-208-3109, Monday to Friday 8:30a to 4:30p, and Wednesday mornings from 9am to 11am at the office. The building permit application asks the applicant to enclose three copies of plans and to give a Michigan builders license number, and the township posts no fee schedule or online portal address on the pages read.

Roof code checklist: Charter Township of Bertrand, MI

ItemAnswerCode citeSourceVerified
Permit to replace a roofYesbertrandtwpmi.gov2026-10-15
Repair permit thresholdPublishedbertrandtwpmi.gov2026-10-15
Layer limit / roof-overPublishedR908.3.1.1codes.iccsafe.org2026-10-15
Deck & sheathingPublishedR905.2.1codes.iccsafe.org2026-10-15
Drip edgeYesR905.2.8.5codes.iccsafe.org2026-10-15
Ice & water shieldYesR905.1.2ars.apps.lara.state.mi.us2026-10-15
Mid-roof inspectionNot published
Impact-resistant (Class 4) roofingNoars.apps.lara.state.mi.us2026-10-15
Wind design criteriaNot published
Adopted codePublishedars.apps.lara.state.mi.us2026-10-15
Contractor license / registrationYeslegislature.mi.gov2026-10-15
Sales & use taxPublishedlegislature.mi.gov2026-10-15

Each row comes from the sourced record on this page; full wording is in the table below. "Not published" means no official source for that item was found when the record was last verified.

Jurisdiction
Charter Township of Bertrand, Michigan
Jurisdiction type
city
Address
3835 Buffalo Road, Buchanan, MI 49107
Contact
  • url: https://bertrandtwpmi.gov/buildingdept
  • phone: 269-695-5001
Roofing permit required
Required
Contractor registration required
Required
Permit process note
Bertrand Charter Township publishes nothing specific to roof work: its Building Department page, Forms and Permits page, building permit application and codified Chapter 6 name no roofing line, no reroof exemption and no size or cost point. With the township silent on reroofs, the state's general permit rule applies: "before construction of a building or structure, the owner, or the owner's builder, architect, engineer, or agent, shall submit an application in writing to the appropriate enforcing agency for a building permit." The same section says "A building permit is not required for ordinary repairs of a building or structure," without defining ordinary repairs, and the township has published no statement applying that relief to roof work. The township's Zoning Ordinance says "A building permit is the written authority as issued by the Building Inspector permitting the construction, moving, alteration or use of a building", the Building Department page says "All of the other inspectors can be reached by the phone number listed on their permit", and the township's agricultural-exemption sheet gives the building department's line, 269-208-3109, Monday to Friday 8:30a to 4:30p, and Wednesday mornings from 9am to 11am at the office. The building permit application asks the applicant to enclose three copies of plans and to give a Michigan builders license number, and the township posts no fee schedule or online portal address on the pages read.
Adopted code
2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." Bertrand Charter Township's codified Sec. 6-25 (Ord. No. 8, § 3, 11-1-1974; Ord. No. 50, § 3, 2-11-1999) makes copies of "the CABO One- and Two-Family Dwelling Code" available for public inspection and names no edition; this directory has not read that text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. Bertrand Charter Township's codified Sec. 6-23 says the township elects to enforce the state construction code "together with all additions, amendments and deletions thereof as adopted by the state construction code commission".
Drip edge
Required — Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on drip edge. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code). About drip edge
Ice & water shield
Required — Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on ice barrier. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code). About ice & water barrier
Impact-resistant roofing
Not required — No impact-resistance requirement under state law. The 2015 Michigan Residential Code was searched in full and has no hail or impact rating rule for roof coverings: the words hail, impact and UL 2218 do not appear in it, and none of them appears in the roof assemblies chapter of the base 2015 International Residential Code either. Michigan applies one code statewide ("This act and the code apply throughout the state."), and the act gives the power to amend it to the state director, who adopts the model codes "with amendments, additions, or deletions as the director determines appropriate." Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on impact resistance.
Repair permit threshold
Bertrand Charter Township has published nothing on reroofs. Its Building Department page says "The building inspector will be in the office every WEDNESDAY morning from 9 am to 11:00 am" and "You can also call the township for assistance – 269-695-5001"; its building permit application is a general form that names no roofing, and the only exemption it publishes is for agricultural buildings, where the township says "If you do not meet both criteria, you will be required to obtain a building permit, before construction begins." Under state law: "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs; the township has published nothing applying that relief to roof work. Call the township or the building department before a reroof or a small roof repair.
Roof layer limit / recover
Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Locally, the township's building ordinance, Chapter 6 of the Bertrand Township Code of Ordinances (Buildings and Building Regulations), was read in full: it designates the building inspector as the enforcing agency, elects to enforce the state construction code, adopts the Appendix G flood provisions and flood maps, and adopts dangerous-building, electrical, mechanical and plumbing codes; it has no reroofing provision and amends nothing in Section R908. The township's chapters on general provisions, administration, businesses, environment, fire prevention, offenses and zoning were searched for roofing text and have no roofing rule. The Building Department page states no layer rule. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code).
Deck & sheathing requirements
State law, from the base code. Michigan makes no amendment to the roof sheathing section of the 2015 International Residential Code, Section R803, which does not appear in the Michigan rule set, so it applies as published. Lumber roof sheathing follows Table R803.1: over rafters or beams 24 inches apart it must be at least 5/8 inch net thick. Wood structural panels must be identified "for grade, bond classification and performance category by a grade mark or certificate of inspection issued by an approved agency," and their spans may not exceed "the values set forth in Table R503.2.1.1(1), or APA E30." For a shingle roof the base code adds that "Asphalt shingles shall be fastened to solidly sheathed decks" (R905.2.1), and on any reroof "The structural roof components shall be capable of supporting the roof covering system" (R908.2). Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on roof sheathing. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code).
Sales & use tax
6%, statewide, with no local add-on. This is state law: the General Sales Tax Act sets the tax "equal to 6% of the gross proceeds of the business," the Use Tax Act sets "a total combined rate equal to 6%," and the Michigan Department of Treasury says "Michigan does not allow city or local units to impose sales tax." On a roofing job the roofer is the taxpayer on materials, because the Use Tax Act counts as a consumer "A person acquiring tangible personal property if engaged in the business of constructing, altering, repairing, or improving the real estate of others." Nothing on the Bertrand Charter Township pages changes this.

Bertrand Charter Township's Building Department, at the township hall at 3835 Buffalo Road in Buchanan, issues building permits, and its building inspector is in the township office on Wednesday mornings from 9 am to 11 am. Section 6-1 of the township's Code of Ordinances designates the township's building inspector as the enforcing agency under the state construction code act, and the State of Michigan's jurisdiction list names the Township as its own building code enforcer. Michigan's single state construction code applies, and for houses that is the 2015 Michigan Residential Code.

Working an insurance claim in Charter Township of Bertrand, MI? Everything on this page (drip edge, ice & water shield, inspections, Class 4 rules) formatted as a claim-ready evidence pack: verbatim ordinance quotes, code section cites, verification dates, and official source links, ready to attach to a supplement. See a real sample pack (PDF, 4 pages, free).

Code items like drip edge and ice & water shield are what adjusters ask you to document.

Buy this jurisdiction's pack: $12 Delivered by email within minutes. Digital download: all sales are final once delivered, except for a failed delivery, a defective file, a duplicate purchase, or a pack materially different from its description. See Section 6 of our Terms of Use.

Questions about the Charter Township of Bertrand, MI pack?

Not ready to buy, or need a different jurisdiction? Tell us and we’ll reply directly.

By submitting, you agree to our Terms of Use and Privacy Policy.

Sources

Roofing questions: Charter Township of Bertrand, MI

Do you need a permit to replace a roof in Charter Township of Bertrand, MI?

Yes, a permit is required to replace a roof in Charter Township of Bertrand, MI. Bertrand Charter Township has published nothing on reroofs. Its Building Department page says "The building inspector will be in the office every WEDNESDAY morning from 9 am to 11:00 am" and "You can also call the township for assistance – 269-695-5001"; its building permit application is a general form that names no roofing, and the only exemption it publishes is for agricultural buildings, where the township says "If you do not meet both criteria, you will be required to obtain a building permit, before construction begins." Under state law: "A building permit is not required for ordinary repairs of a building or structure." (MCL 125.1510), without a definition of ordinary repairs; the township has published nothing applying that relief to roof work. Call the township or the building department before a reroof or a small roof repair.

Is ice & water shield required in Charter Township of Bertrand, MI?

Yes. Required everywhere in Michigan by state law. Michigan fills in the climatic design table of the 2015 code once for the whole state (Rule 516, Table R301.2(1)), and its ice barrier underlayment column reads Yes. The state footnote calls for Yes "for areas where the average daily temperature in January is 25 degrees Fahrenheit" or less, or where ice damming has caused damage. The base code then requires an ice barrier "for asphalt shingles, metal roof shingles, mineral-surfaced roll roofing, slate and slate-type shingles, wood shingles and wood shakes," running "from the lowest edges of all roof surfaces to a point not less than 24 inches (610 mm) inside the exterior wall line of the building" (R905.1.2). Detached accessory structures without conditioned floor area are exempt. On a tear-off, an existing ice barrier that is adhered to the deck may stay and be covered with an additional layer (R908.3, Exception). Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on ice barrier. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code).

Is drip edge required in Charter Township of Bertrand, MI?

Yes. Required on asphalt shingle roofs by state law. Michigan makes no amendment to the drip edge rule of the 2015 International Residential Code, Section R905.2.8.5, which applies as published: "A drip edge shall be provided at eaves and rake edges of shingle roofs." Segments overlap by at least 2 inches, the drip edge extends at least 1/4 inch below the roof sheathing and at least 2 inches back onto the deck, it is fastened at no more than 12 inches on center, and underlayment goes over it at the eaves and under it at the rakes. A reroof is held to the same rule, because "Materials and methods of application used for re-covering or replacing an existing roof covering shall comply with the requirements of Chapter 9" (R908.1). Chapter 6 of the Bertrand Township Code of Ordinances, the Building Department and Forms and Permits pages and the building permit application were read for a local rule and state nothing further on drip edge. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code).

Can you roof over an existing roof in Charter Township of Bertrand, MI?

Two layers at most, under state law. Michigan builds one- and two-family homes to the 2015 Michigan Residential Code, which adopts the 2015 International Residential Code and makes no amendment to its reroofing section, Section R908; the Michigan rule set was searched in full and R908 does not appear in it. The base section therefore applies as the International Code Council publishes it. Section R908.3.1.1 lists the conditions under which a new roof may not be laid over an existing one, and the third is "Where the existing roof has two or more applications of any type of roof covering." One existing layer may be covered once; a roof that already carries two layers is torn off to the deck. The same section also bars covering a roof that is water soaked or too deteriorated to serve as a base, and covering "slate, clay, cement or asbestos-cement tile." Locally, the township's building ordinance, Chapter 6 of the Bertrand Township Code of Ordinances (Buildings and Building Regulations), was read in full: it designates the building inspector as the enforcing agency, elects to enforce the state construction code, adopts the Appendix G flood provisions and flood maps, and adopts dangerous-building, electrical, mechanical and plumbing codes; it has no reroofing provision and amends nothing in Section R908. The township's chapters on general provisions, administration, businesses, environment, fire prevention, offenses and zoning were searched for roofing text and have no roofing rule. The Building Department page states no layer rule. Bertrand Charter Township's codified Sec. 6-25 refers to the CABO One- and Two-Family Dwelling Code; this field states the 2015 Michigan Residential Code, which the state act applies throughout the state and which the township's codified Sec. 6-23 says it enforces as adopted by the state construction code commission; the CABO text was not read (see adopted_code).

Do roofing contractors need a license or registration in Charter Township of Bertrand, MI?

Yes.

What building code does Charter Township of Bertrand, MI use?

2015 Michigan Residential Code. This is state law and it is the same in every Michigan city, village, township and county: the state construction code act says "This act and the code apply throughout the state," and the Michigan Residential Code rule adopts "the international residential code, 2015 edition" with the state amendments in R 408.30500 to R 408.30547g. A 2021 edition was filed with the secretary of state in 2025 but has not taken effect. On July 7, 2025 the Michigan Court of Claims entered a stipulated order in Home Builders Assoc et al. v LARA et al., and the Michigan Department of Licensing and Regulatory Affairs (LARA) says that while that order remains in place "the 2015 versions of the IRC and residential provisions of the IECC standards currently adopted, in part, by each rule set will remain valid and in effect." Bertrand Charter Township's codified Sec. 6-25 (Ord. No. 8, § 3, 11-1-1974; Ord. No. 50, § 3, 2-11-1999) makes copies of "the CABO One- and Two-Family Dwelling Code" available for public inspection and names no edition; this directory has not read that text, and whether the codified reference has any effect today is not decided here. This record states the 2015 Michigan Residential Code, which the state construction code act applies throughout the state ("This act and the code apply throughout the state," MCL 125.1508a) and which LARA says remains in effect while the Court of Claims order of July 7, 2025 stands. Bertrand Charter Township's codified Sec. 6-23 says the township elects to enforce the state construction code "together with all additions, amendments and deletions thereof as adopted by the state construction code commission".