Products / Medallion I and Medallion II
Medallion I and Medallion II
UL 2218 Class 4McElroy Metal's snap-on batten seam roof systems, in which a separate batten cap is installed over adjoining panels held by hidden clips. Medallion I has a 1-inch rib and a narrower cap; Medallion II has a 1 1/2-inch rib and a wider cap. Panels come in 12, 16 or 18-inch widths in 24 gauge Galvalume finished in Kynar 500 PVDF or acrylic-coated Galvalume, in factory lengths up to 75 feet, for solid deck at a minimum slope of 3:12. McElroy lists UL 263 Class A, UL 580 Class 90, UL 2218 Class 4 and ASTM E1592 for the system.
Manufacturer
Material
Product line
Standing Seam Metal Roofing Systems
Impact class
UL 2218 Class 4Standards met
UL 263UL 580 Class 90UL 2218 Class 4ASTM E1592
Status
active
Spec sheet
Sources
- mcelroymetal.com verified 2026-10-15