Permitting Authorities / City of Canal Winchester - Building Division

Do you need a permit to replace a roof in Canal Winchester, OH?

Adopted code

City of Canal Winchester - Building Division

Yes, a permit is required to replace a roof in Canal Winchester, OH, issued by City of Canal Winchester - Building Division.

Jurisdiction
City of Canal Winchester, Ohio
Jurisdiction type
city
Address
45 E. Waterloo Street, Canal Winchester, OH 43110
Contact
  • url: https://www.canalwinchesterohio.gov/147/Building
  • phone: 614-837-7501
Roofing permit required
Required
Adopted code
The Residential Code of Ohio (RCO), Ohio Administrative Code Division 4101:8, adopted by the Ohio Board of Building Standards, governs one-, two- and three-family dwellings statewide; its roof assemblies rule (OAC 4101:8-9-01) and administration rule (OAC 4101:8-1-01) carry an effective date of July 1, 2019. Ohio Rev. Code 3781.01(B) provides that the state residential building code "does not prevent a local governing authority from adopting additional regulations governing residential structures that do not conflict with the state residential building code". Under RCO 101.5, where no building department certified by the Board of Building Standards for residential buildings has jurisdiction, "the owner is not required to make submission of construction documents, seek approvals, request inspections, or obtain certificates of occupancy". In Canal Winchester, the city Building Division reviews plans for code compliance, issues permits to build and provides on-site inspections to ensure conformity with approved plans. This record did not read Canal Winchester's own codified ordinances, so any additional local building regulation is not reflected here.
Ice & water shield
Required — SET BY STATE RULE. Table 301.2(1) of the Residential Code of Ohio (OAC 4101:8-3-01) marks ice barrier underlayment as required, and its footnote h states that "all jurisdictions in Ohio have a history of local damage from the effects of ice damming". RCO 905.1.2 then requires the ice barrier for asphalt shingles and the other listed coverings, consisting of "not fewer than two layers of underlayment cemented together, or a self-adhering polymer-modified bitumen sheet", extending from the lowest edges of all roof surfaces "to a point not less than 24 inches (610 mm) inside the exterior wall line of the building", and on slopes of 8 in 12 or steeper not less than 36 inches measured along the slope from the eave edge. The section's own exception covers "Detached accessory structures and roof assemblies terminating at a vertical wall over unconditioned floor areas". Ohio Rev. Code 3781.01(B) lets a city add regulations that do not conflict with the state code; this record did not read Canal Winchester's own ordinances. About ice & water barrier
Deck & sheathing requirements
SET BY STATE RULE. RCO 905.2.1 (OAC 4101:8-9-01) provides: "Asphalt shingles shall be fastened to solidly sheathed decks." RCO 905.6.1 sets the same rule for slate: "Slate shingles shall be fastened to solidly sheathed roofs." Ohio Rev. Code 3781.01(B) lets a city add regulations that do not conflict with the state code; this record did not read Canal Winchester's own ordinances.

The City of Canal Winchester Building Division, at 45 E. Waterloo Street in Canal Winchester (a city in Franklin and Fairfield counties), reviews plans for code compliance, issues building permits and carries out on-site inspections in the city. Its applications page lists a "Residential Roof Application" under "Building Applications & Permits", and that form, titled "Residential Roof Permit Application", states that "Both a rough and final inspection are required." The Residential Code of Ohio applies to one-, two- and three-family dwellings in Canal Winchester as it does statewide. This listing covers the office's contact details, its roofing permit rule where the office's own page states one, and the rules state law sets for every Ohio jurisdiction; it does not cover Canal Winchester's own codified building ordinances.

Sources

Roofing questions: Canal Winchester, OH

Do you need a permit to replace a roof in Canal Winchester, OH?

Yes, a permit is required to replace a roof in Canal Winchester, OH.

Is ice & water shield required in Canal Winchester, OH?

Yes. SET BY STATE RULE. Table 301.2(1) of the Residential Code of Ohio (OAC 4101:8-3-01) marks ice barrier underlayment as required, and its footnote h states that "all jurisdictions in Ohio have a history of local damage from the effects of ice damming". RCO 905.1.2 then requires the ice barrier for asphalt shingles and the other listed coverings, consisting of "not fewer than two layers of underlayment cemented together, or a self-adhering polymer-modified bitumen sheet", extending from the lowest edges of all roof surfaces "to a point not less than 24 inches (610 mm) inside the exterior wall line of the building", and on slopes of 8 in 12 or steeper not less than 36 inches measured along the slope from the eave edge. The section's own exception covers "Detached accessory structures and roof assemblies terminating at a vertical wall over unconditioned floor areas". Ohio Rev. Code 3781.01(B) lets a city add regulations that do not conflict with the state code; this record did not read Canal Winchester's own ordinances.

What building code does Canal Winchester, OH use?

The Residential Code of Ohio (RCO), Ohio Administrative Code Division 4101:8, adopted by the Ohio Board of Building Standards, governs one-, two- and three-family dwellings statewide; its roof assemblies rule (OAC 4101:8-9-01) and administration rule (OAC 4101:8-1-01) carry an effective date of July 1, 2019. Ohio Rev. Code 3781.01(B) provides that the state residential building code "does not prevent a local governing authority from adopting additional regulations governing residential structures that do not conflict with the state residential building code". Under RCO 101.5, where no building department certified by the Board of Building Standards for residential buildings has jurisdiction, "the owner is not required to make submission of construction documents, seek approvals, request inspections, or obtain certificates of occupancy". In Canal Winchester, the city Building Division reviews plans for code compliance, issues permits to build and provides on-site inspections to ensure conformity with approved plans. This record did not read Canal Winchester's own codified ordinances, so any additional local building regulation is not reflected here.